FEASIBILITY OF PERCUTANEOUS CONTRAST ULTRASOUND-GUIDED CHOLECYSTOGRAPHY IN DOGS

被引:5
|
作者
Ji, Seoyeoun [1 ]
Jung, Sunyoung [1 ]
Kim, Boeun [1 ]
Jung, Joohyun [1 ]
Yoon, Junghee [1 ]
Choi, Mincheol [1 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Vet Med Imaging, Seoul 151742, South Korea
关键词
percutaneous ultrasound-guided cholecystography; SonoVue; ultrasound contrast agent; ENHANCED-ULTRASOUND; BILE-DUCT; OBSTRUCTION; DIAGNOSIS; JAUNDICE; CHOLANGIOGRAPHY; ULTRASONOGRAPHY; SURGERY;
D O I
10.1111/vru.12224
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Differentiating hepatocellular disease versus biliary obstruction can be challenging in dogs presented for icterus. The purpose of this prospective study was to determine the feasibility of percutaneous contrast ultrasound-guided cholecystography in dogs. Ten normal dogs weighing 7.6-13.0 kg (median 9.8 kg) were recruited. All dogs were considered normal based on complete blood count, serum chemistry profile, ultrasound examination, and percutaneous radiographic cholecystography. Percutaneous contrast ultrasound-guided cholecystography was performed using 0.5 ml of commercially available contrast agent and two conventional ultrasound machines for simultaneous scanning at two different locations. Two observers independently evaluated the time to initial detection of contrast in the proximal duodenum and duration of contrast enhancement via visual monitoring. Dynamic contrast enhancement was calculated using time-intensity curves. Mean (+/- SD) and median (range) of time to initial detection were 8.60 s (+/- 3.35) and 8.0 s (2.0-11.0), respectively, and mean and median duration were 50.45 s (+/- 23.24) and 53.0 s (20.0 - 70.0), respectively. Mean, median, and range of peak intensity were 114.1 mean pixel value (MPV) (SD +/- 30.7), 109.2 MPV, and 79.7-166.7, respectively, and mean, median, and range of time to peak intensity were 26.1 s (SD +/- 7.1 s), 24.0 s, and 19.0-41.0 s, respectively. Findings indicated that percutaneous contrast ultrasound-guided cholecystography is a feasible technique for detecting and quantifying patency of the bile duct in normal dogs. Future studies are needed to assess the diagnostic utility of this technique for dogs with biliary obstruction.
引用
收藏
页码:296 / 300
页数:5
相关论文
共 50 条
  • [41] Feasibility of conversion of percutaneous cholecystostomy to internal transmural endoscopic ultrasound-guided gallbladder drainage
    Chantarojanasiri, Tanyaporn
    Matsubara, Saburo
    Isayama, Hiroyuki
    Nakai, Yousuke
    Takahara, Naminatsu
    Mizuno, Suguru
    Kogure, Hirofumi
    Hakuta, Ryunosuke
    Ito, Yukiko
    Tada, Minoru
    Koike, Kazuhiko
    SAUDI JOURNAL OF GASTROENTEROLOGY, 2017, 23 (06): : 218 - 222
  • [42] Feasibility of Ultrasound-guided Percutaneous Samplings in the Pregnant Baboon: A Model for Studies on Transplacental Transport
    Van Calsteren, Kristel
    Devlieger, Roland
    De Catte, Luc
    D'Hooghe, Thomas
    Chai, Daniel C.
    Mwenda, Jason M.
    Vergote, Ignace
    Amant, Frederic
    REPRODUCTIVE SCIENCES, 2009, 16 (03) : 280 - 285
  • [43] Feasibility of the conversion of percutaneous cholecystostomy to internal transmural endoscopic ultrasound-guided gallbladder drainage
    Teoh, Anthony Y. B.
    SAUDI JOURNAL OF GASTROENTEROLOGY, 2017, 23 (06): : 209 - 210
  • [44] The feasibility and efficacy of ultrasound-guided percutaneous laser ablation for multifocal papillary thyroid microcarcinoma
    Zhang, Lu
    Zhang, Gui Ping
    Zhan, Wei Wei
    Zhou, Wei
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [45] Feasibility of Ultrasound-Guided Transoccluded Radial Access for Coronary Angiography or Percutaneous Coronary Intervention
    Mori, Shinsuke
    Hirano, Keisuke
    Makino, Kenji
    Honda, Yohsuke
    Tsutsumi, Masakazu
    Sakamoto, Yasunari
    Kobayashi, Norihiro
    Araki, Motoharu
    Yamawaki, Masahiro
    Ito, Yoshiaki
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (17) : 2088 - 2090
  • [46] ULTRASOUND-GUIDED PERCUTANEOUS TRANSHEPATIC PORTACAVAL-SHUNT - A FEASIBILITY STUDY ON PIGS LIVER
    SOLINAS, A
    MOSCA, S
    CAPORALI, S
    DISTRUTTI, E
    BARZI, F
    AGOSTINO, HBD
    MORELLI, A
    GASTROENTEROLOGY, 1995, 108 (04) : A1174 - A1174
  • [47] Analysis of feasibility, safety and effectiveness of ultrasound-guided percutaneous microwave ablation of splenic neoplasm
    Luo, Na
    Wang, Yan
    Geng, Zhe
    Qin, Xiantao
    ONCOLOGY LETTERS, 2018, 16 (04) : 4807 - 4812
  • [48] Feasibility, safety, and efficacy of ultrasound-guided percutaneous microwave ablation for giant hepatic hemangioma
    Wang, Zhi
    Tang, Xiaoyin
    Qi, Xingxing
    Shi, Yaoping
    Chi, Jiachang
    Li, Ping
    Zhai, Bo
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 246 - 252
  • [49] Contrast-Enhanced Ultrasound-Guided Percutaneous Biopsy of the Peritoneum A Series of 3 Cases
    Panarisi, Nicol Antonina Rita
    Cascella, Tommaso
    Morosi, Carlo
    Greco, Francesca Gabriella
    Marchiano, Alfonso
    Lanocita, Rodolfo
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (07) : 1441 - 1446
  • [50] Efficacy, safety and feasibility of ultrasound-guided percutaneous microwave ablation for large hepatic hemangioma
    Tang, Xiao Yin
    Wang, Zhi
    Wang, Tao
    Cui, Dan
    Zhai, Bo
    JOURNAL OF DIGESTIVE DISEASES, 2015, 16 (09) : 525 - 530