99mTc-MIBI SPECT/CT SCINTIGRAPHY AND ULTRASOUND OF THE ANTERIOR NECK REGION IN DIAGNOSING PARATHYROID GLAND PATHOLOGY IN PATIENTS WITH THYROID NODULES

被引:2
|
作者
Nenadic, Vedrana Gladic [1 ]
Markos, Ines Sisko [1 ]
Punda, Marija [1 ]
Blazekovic, Ivan [1 ]
Franceschi, Maja [1 ]
Frobe, Ana [1 ]
Jukic, Tomislav [1 ]
机构
[1] Sestre Milosrdnice Univ Hosp Ctr, Dept Oncol & Nucl Med, Vinogradska C 29, HR-10000 Zagreb, Croatia
关键词
Tc-99m-MIBI; SPECT/CT; Hyperparathyroidism; Parathyroid hormone; Fine needle aspiration; FINE-NEEDLE-ASPIRATION; SESTAMIBI; SENSITIVITY;
D O I
10.20471/acc.2021.60.03.12
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Parathyroid scintigraphy with Tc-99m-MIBI is an imaging technique used in nuclear medicine and performed in patients with suspected hyperparathyroidism (HPT). The objective of this study was to evaluate the role of this technique in patients who, along with suspected HPT, also have thyroid nodules. Retrospective analysis included a period of 8 years (2006-2013). The study included 91 patients with clinical or laboratory suspected HPT. Pathologic changes in parathyroid glands were demonstrated in 47 (70%) of 67 patients with positive scintigraphy. Pathologic changes in parathyroid glands were not evident in the remaining 20 (30%) patients. Out of nine patients with negative scintigraphy results but with suspected enlargement of the parathyroid gland examined by ultrasound, eight (89%) patients did not show pathologic changes in the parathyroid gland, whereas one (11%) patient had evident changes. Eight (54%) of 15 patients with suspected scintigraphy had positive ultrasound findings, as well as fine needle aspiration cytology (FNAC) findings with parathyroid hormone (PTH) determination in the aspirate. Seven (46%) patients had negative FNAC findings and PTH in the aspirate. The study showed scintigraphy to have high sensitivity (98%) in detecting patients with pathologic changes in the parathyroid glands. In patients with suspected HPT, scintigraphy needs to be combined with FNAC and PTH determination in the aspirate due to its low specificity of 28%.
引用
收藏
页码:423 / 428
页数:6
相关论文
共 50 条
  • [31] Influence of thyroid size, thyroid nodules, and SPECT on the results of parathyroid scintigraphy with Tc-99m MIBI
    Gotthardt, M
    Karakas, E
    Sieber, V
    Goecke, J
    Heinis, J
    Pfestroff, A
    Höffken, H
    Rothmund, M
    Zielke, A
    Behr, TM
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S246 - S246
  • [32] Comparison of 99mTc-MIBI planar scintigraphy, SPET/CT and ultrasonography in detection of parathyroid adenoma in patients with primary hyperparathyroidism
    Ozdemir, Elif
    Genc, Mustafa
    Aydos, Uguray
    Polat, Sefika Burcak
    Kandemir, Zuhal
    Tam, Ali Abbas
    Yildirim, Nilufer
    TurkolmeZ, Seyda
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2020, 23 (01): : 21 - 26
  • [33] Improvement of parathyroid lesion visualization in primary hyperparathyroidism with 99mTc-MIBI pinhole SPECT:: comparison with conventional SPECT and planar scintigraphy
    Ansquer, C.
    Mirallie, E.
    Oudoux, A.
    Bodet-Milin, C.
    Defrise, M.
    Seret, A.
    Daumy, I.
    Aubron, F.
    Kraeber-Bodere, F.
    Carlier, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S100 - S100
  • [34] Benign Parathyroid Hyperplasia With Incidental Pulmonary Seeding on 99mTc-MIBI Scintigraphy and FDG PET/CT
    Tsai, Yao-Kuang
    Tsai, Chi-Jung
    Chiu, Chuang-Hsin
    Ko, Kai-Hsiung
    Li, Yao-Feng
    CLINICAL NUCLEAR MEDICINE, 2022, 47 (03) : E329 - E330
  • [35] The Ability of Contrast-Enhanced Ultrasound, Conventional Ultrasound, and 99mTc-MIBI Scintigraphy for the Detection of Parathyroid Lesion in Patients with Primary Hyperparathyroidism
    Alramadhan, Maryam M.
    Alsolai, A.
    Eisa, Rana A.
    Gareeballah, Awadia
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2022, 12 (01) : 82 - 88
  • [36] Dual-phase 99mTc-MIBI scintigraphy with delayed neck and thorax SPECT/CT and bone scintigraphy in patients with primary hyperparathyroidism: correlation with clinical or pathological variables
    Qiu, Zhong-Ling
    Wu, Bo
    Shen, Chen-Tian
    Zhu, Rui-Sen
    Luo, Quan-Yong
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (08) : 725 - 735
  • [37] Dual-phase 99mTc-MIBI scintigraphy with delayed neck and thorax SPECT/CT and bone scintigraphy in patients with primary hyperparathyroidism: correlation with clinical or pathological variables
    Zhong-Ling Qiu
    Bo Wu
    Chen-Tian Shen
    Rui-Sen Zhu
    Quan-Yong Luo
    Annals of Nuclear Medicine, 2014, 28 : 725 - 735
  • [38] Preoperative parathyroid lesion localization with 99mTc-MIBI SPECT & SPECT/CT: Iterative versus filtered backprojection reconstruction
    Nichols, Kenneth
    Tronco, Gene
    Palestro, Christopher
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [39] Hyperparathyroidism detection using 99mTc-MIBI SPECT/low dose CT and 3D subtraction methods of 99mTc-MIBI SPECT-99mTcO4 SPECT in patients with osteoporosis
    Chroustova, D.
    Stepan, J.
    Kubinyi, J.
    Trnka, J.
    Adamek, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S571 - S571
  • [40] The incremental value of 99mTc-pertechnetate thyroid imaging for the evaluation of parathyroid disease with dual phase 99mTc-MIBI scintigraphy.
    Yudd, AP
    Kempf, JS
    Becker, MD
    Amorosa, LF
    Saul, JM
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 311P - 311P