X-ray extended-range technique for precision measurement of the X-ray mass attenuation coefficient and Im(f) for copper using synchrotron radiation

被引:48
|
作者
Chantler, CT [1 ]
Tran, CQ
Paterson, D
Cookson, D
Barnea, Z
机构
[1] Univ Melbourne, Sch Phys, Melbourne, Vic 3010, Australia
[2] Argonne Natl Lab, Chem Mat CARS CAT, Argonne, IL 60439 USA
[3] Australian Nucl Sci & Technol Org, Menai, NSW 2234, Australia
关键词
D O I
10.1016/S0375-9601(01)00444-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We reconsider the long-standing problem of accurate measurement of atomic form factors for fundamental and applied problems. We discuss the X-ray extended-range technique for accurate measurement of the mass attenuation coefficient and the imaginary component of the atomic form factor. Novelties of this approach include the use of a synchrotron with detector normalisation, the direct calibration of dominant systematics using multiple thicknesses, and measurement over wide energy ranges with a resulting improvement of accuracies by an order of magnitude. This new technique achieves accuracies of 0.27-0.5% and reproducibility of 0.02% for attenuation of copper from 8.84 to 20 keV, compared to accuracies of 10% using atomic vapours. This precision challenges available theoretical calculations. Discrepancies of 10% between current theory and experiments can now be addressed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:338 / 346
页数:9
相关论文
共 50 条
  • [31] Observation of X-ray shadings in synchrotron radiation-total reflection X-ray fluorescence using a color X-ray camera
    Fittschen, Ursula Elisabeth Adriane
    Menzel, Magnus
    Scharf, Oliver
    Radtke, Martin
    Reinholz, Uwe
    Buzanich, Guenther
    Lopez, Velma M.
    McIntosh, Kathryn
    Streli, Christina
    Havrilla, George Joseph
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 99 : 179 - 184
  • [32] SCANNING X-RAY MICROSCOPE USING SYNCHROTRON RADIATION
    HOROWITZ, P
    SCIENCE, 1972, 178 (4061) : 608 - &
  • [33] AN X-RAY MICROPROBE FACILITY USING SYNCHROTRON RADIATION
    GORDON, BM
    JONES, KW
    HANSON, AL
    POUNDS, JG
    RIVERS, ML
    SPANNE, P
    SUTTON, SR
    BIOLOGICAL TRACE ELEMENT RESEARCH, 1990, 26-7 : 133 - 141
  • [34] X-RAY EXPERIMENTS USING SYNCHROTRON RADIATION AT A SOURCE
    EISENBERGER, P
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (01): : 51 - 51
  • [35] The X-ray measurements of the supermirror using synchrotron radiation
    Okajima, T
    Ichimaru, S
    Tamura, K
    Haga, K
    Ogasaka, Y
    Takahashi, S
    Fukuda, S
    Kitou, H
    Gotou, A
    Tawara, Y
    Yamashita, K
    Tsusaka, Y
    Takeda, S
    Kunieda, H
    ADVANCES IN X-RAY OPTICS, 2001, 4145 : 53 - 60
  • [36] X-RAY HOLOGRAM OBTAINED BY USING SYNCHROTRON RADIATION
    AOKI, S
    ICHIHARA, Y
    KIKUTA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1972, 11 (12) : 1857 - 1857
  • [37] ON THE DEVELOPMENT OF X-RAY MICROPROBES USING SYNCHROTRON RADIATION
    VIS, RD
    VANLANGEVELDE, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 54 (1-3): : 417 - 423
  • [38] X-ray diffraction microtomography using synchrotron radiation
    Barroso, RC
    Lopes, RT
    de Jesus, EFO
    Oliveira, LF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 75 - 79
  • [39] X-RAY TOPOGRAPHY USING SYNCHROTRON-RADIATION
    WIETESKA, K
    ACTA PHYSICA POLONICA A, 1994, 86 (04) : 545 - 552
  • [40] A TUNABLE X-RAY MICROPROBE USING SYNCHROTRON RADIATION
    WU, Y
    THOMPSON, AC
    UNDERWOOD, JH
    GIAUQUE, RD
    CHAPMAN, K
    RIVERS, ML
    JONES, KW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2): : 146 - 151