X-ray extended-range technique for precision measurement of the X-ray mass attenuation coefficient and Im(f) for copper using synchrotron radiation

被引:48
|
作者
Chantler, CT [1 ]
Tran, CQ
Paterson, D
Cookson, D
Barnea, Z
机构
[1] Univ Melbourne, Sch Phys, Melbourne, Vic 3010, Australia
[2] Argonne Natl Lab, Chem Mat CARS CAT, Argonne, IL 60439 USA
[3] Australian Nucl Sci & Technol Org, Menai, NSW 2234, Australia
关键词
D O I
10.1016/S0375-9601(01)00444-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We reconsider the long-standing problem of accurate measurement of atomic form factors for fundamental and applied problems. We discuss the X-ray extended-range technique for accurate measurement of the mass attenuation coefficient and the imaginary component of the atomic form factor. Novelties of this approach include the use of a synchrotron with detector normalisation, the direct calibration of dominant systematics using multiple thicknesses, and measurement over wide energy ranges with a resulting improvement of accuracies by an order of magnitude. This new technique achieves accuracies of 0.27-0.5% and reproducibility of 0.02% for attenuation of copper from 8.84 to 20 keV, compared to accuracies of 10% using atomic vapours. This precision challenges available theoretical calculations. Discrepancies of 10% between current theory and experiments can now be addressed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:338 / 346
页数:9
相关论文
共 50 条
  • [1] X-RAY EXTENDED-RANGE TECHNIQUE FOR PRECISION MEASUREMENT OF THE X-RAY MASS ATTENUATION COEFFICIENT AND IM(F) FOR MOLYBDENUM USING SYNCHROTRON RADIATION
    de Jonge, M. D.
    Tran, C. Q.
    Barnea, Z.
    Dhal, B. B.
    Cookson, D. J.
    Chantler, C. T.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C82 - C82
  • [2] Measurement of the x-ray mass attenuation coefficient of silver using the x-ray-extended range technique
    Tran, CQ
    Chantler, CT
    Barnea, Z
    de Jonge, MD
    Dhal, BB
    Chung, CTY
    Paterson, D
    Wang, J
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2005, 38 (01) : 89 - 107
  • [3] Measurement of the x-ray mass attenuation coefficient of copper using 8.85-20 keV synchrotron radiation
    Chantler, CT
    Tran, CQ
    Barnea, Z
    Paterson, D
    Cookson, DJ
    Balaic, DX
    PHYSICAL REVIEW A, 2001, 64 (06): : 15
  • [4] New consistency tests for high-accuracy measurements of X-ray mass attenuation coefficients by the X-ray extended-range technique
    Chantler, C. T.
    Islam, M. T.
    Rae, N. A.
    Tran, C. Q.
    Glover, J. L.
    Barnea, Z.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2012, 68 : 188 - 195
  • [5] Measurement of X-ray mass attenuation coefficient of nickel around the K-edge using synchrotron radiation based X-ray absorption study
    Roy, Bunty Rani
    Rajput, Parasmani
    Jha, S. N.
    Rao, A. S. Nageswara
    RADIATION PHYSICS AND CHEMISTRY, 2015, 114 : 38 - 42
  • [6] Measurement of the x-ray mass attenuation coefficient and the imaginary part of the form factor of silicon using synchrotron radiation
    Tran, CQ
    Chantler, CT
    Barnea, Z
    Paterson, D
    Cookson, DJ
    PHYSICAL REVIEW A, 2003, 67 (04):
  • [7] The X-ray Extended Range Technique a model for investigating X-ray and electron collision processes at a synchrotron.
    Chantler, Christopher T.
    XXVII INTERNATIONAL CONFERENCE ON PHOTONIC, ELECTRONIC AND ATOMIC COLLISIONS (ICPEAC 2011), PTS 1-15, 2012, 388
  • [8] MEASUREMENT OF SYNCHROTRON RADIATION IN X-RAY REGION
    BATHOW, G
    FREYTAG, E
    HAENSEL, R
    JOURNAL OF APPLIED PHYSICS, 1966, 37 (09) : 3449 - &
  • [9] MEASUREMENT TECHNOLOGY AND APPLICATIONS TO SYNCHROTRON RADIATION EXPERIMENTS IN X-RAY RANGE
    BONSE, U
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 1977, 146 (1-3): : 92 - 92
  • [10] Multiwave supermonochromators for synchrotron radiation of the X-ray range
    Poverkhnost Fizika Khimiya Mekhanika, 1996, (3-4): : 314 - 320