Synthetic dataset generation for the analysis and the evaluation of image-based hemodynamics of the human aorta

被引:19
|
作者
Morbiducci, Umberto [1 ]
Ponzini, Raffaele [2 ]
Rizzo, Giovanna [3 ]
Biancolini, Marco Evanghelos [4 ]
Iannaccone, Francesco [5 ]
Gallo, Diego [1 ]
Redaelli, Alberto [6 ]
机构
[1] Politecn Torino, Dept Mech, I-10129 Turin, Italy
[2] CILEA Interuniv Consortium, HPC Grp, Milan, Italy
[3] IBFM CNR, San Raffaele Sci Inst, Milan, Italy
[4] Univ Roma Tor Vergata, Dept Mech Engn, Rome, Italy
[5] Univ Ghent, IBiTech BioMMeda, B-9000 Ghent, Belgium
[6] Politecn Milan, Dept Bioengn, I-20133 Milan, Italy
关键词
Computational hemodynamics; Phase contrast MRI; Thoracic aorta; Image interpolation; Synthetic dataset; PHASE-CONTRAST MRI; WALL SHEAR-STRESS; CAROTID BIFURCATION; BLOOD-FLOW; BULK FLOW; VELOCITY; PATTERNS; MODELS; BYPASS; SIGNAL;
D O I
10.1007/s11517-011-0854-8
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Here, we consider the issue of generating a suitable controlled environment for the evaluation of phase contrast (PC) MRI measurements. The computational framework, tailored to build synthetic datasets, is based on a two-step approach, i.e., define and implement (1) an accurate CFD model and (2) an image generator able to mime the overall outcomes of a PC MRI acquisition starting from datasets retrieved by the computational model. About 20 different datasets were built by changing relevant image parameters (pixel size, slice thickness, time frames per cardiac cycle). Focusing our attention on the thoracic aorta, synthetic images were processed in order to: (1) verify to which extent the fluid dynamics into the aortic arch is influenced by the image parameters; (2) establish the effect of spatial and temporal interpolation. Our study demonstrates that the integral scale of the aortic bulk flow could be described satisfactorily even when using images which are nowadays acquirable with MRI scanners. However, attention must be paid to near-wall velocities that can be affected by large inaccuracy. In detail, in bulk flow regions error values are well bounded (below 5% for most of the analyzed resolutions), while errors greater than 100% are systematically present at the vessel's wall. Moreover, also the data interpolation process can be responsible for large inaccuracies in new data generation, due to the inherent complexity of the flow field in some connected regions.
引用
收藏
页码:145 / 154
页数:10
相关论文
共 50 条
  • [41] An image-based modeling framework for patient-specific computational hemodynamics
    Luca Antiga
    Marina Piccinelli
    Lorenzo Botti
    Bogdan Ene-Iordache
    Andrea Remuzzi
    David A. Steinman
    Medical & Biological Engineering & Computing, 2008, 46
  • [42] Ultrasound Image Dataset for Image Analysis Algorithms Evaluation
    Cortes, Camilo
    Kabongo, Luis
    Macia, Ivan
    Ruiz, Oscar E.
    Florez, Julian
    INNOVATION IN MEDICINE AND HEALTHCARE 2015, 2016, 45 : 447 - 457
  • [43] Image-based finite element Modeling of Hemodynamics in stenosed carotid artery
    Cebral, JR
    Löhner, R
    Soto, O
    Choyke, PL
    Yim, PJ
    MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 : 297 - 304
  • [44] Dosimetric Evaluation of Multi-sequence MR Image-based Synthetic CT Generation for Head and Neck MR-only Radiotherapy
    Li, Y.
    Qi, M.
    Wu, A.
    Zhou, L.
    Deng, X.
    Song, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E291 - E292
  • [45] Generation of Patient-Specific Cardiac Vascular Networks: A Hybrid Image-Based and Synthetic Geometric Model
    Jaquet, Clara
    Najman, Laurent
    Talbot, Hugues
    Grady, Leo
    Schaap, Michiel
    Spain, Buzzy
    Kim, Hyun Jin
    Vignon-Clementel, Irene
    Taylor, Charles A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 946 - 955
  • [46] Image-based optical detecting system used for the analysis of human activities
    Tang, JK
    Cao, DH
    Wu, YB
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150
  • [47] Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity
    Cebral, JR
    Castro, MA
    Appanaboyina, S
    Putman, CM
    Millan, D
    Frangi, AF
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) : 457 - 467
  • [48] Robustness of Image-Based Malware Analysis
    Tran, Katrina
    Di Troia, Fabio
    Stamp, Mark
    SILICON VALLEY CYBERSECURITY CONFERENCE, SVCC 2022, 2022, 1683 : 3 - 21
  • [49] Image-Based Analysis of Protein Stability
    Hickman, K. Ashley
    Hariharan, Santosh
    De Melo, Jason
    Ylanko, Jarkko
    Lustig, Lindsay C.
    Penn, Linda Z.
    Andrews, David W.
    CYTOMETRY PART A, 2020, 97 (04) : 363 - 377
  • [50] Image-based evaluation of seam puckering appearance
    Xin, Binjie
    Baciu, George
    Hu, Jinlian
    JOURNAL OF ELECTRONIC IMAGING, 2008, 17 (04)