Requirements for accurate anatomical imaging of the rat for electromagnetic modeling

被引:0
|
作者
Lapin, GD [1 ]
Allen, C [1 ]
机构
[1] ComBioMed Labs, Deerfield, IL 60015 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Modeling electromagnetic energy distribution in laboratory test animals, such as the rat, requires accurate imaging of the animal's anatomy. Accuracy, in this sense, refers to the proper positioning and shape of the various organs of the animal as they are situated in the laboratory setting. A number of factors related to the accuracy of bioelectromagnetic studies dictate the required animal positioning. We performed whole body imaging of Sprague-Dawly rats in an x-ray computed tomography (CT) scanner. By necessity the rats were anesthetized during imaging and a whole body thermoplastic cast was made to support the organs in the same position as they were in an awake rat. Comparisons were made to unsupported anesthetized rats and dead rats. We conclude that it is necessary for rats to be supported in a whole-body cast to best simulate the anatomy of the awake rat. In addition, we note changes in abdominal structures due to death that necessitate the analysis of the animal while it is still alive.
引用
收藏
页码:2480 / 2483
页数:4
相关论文
共 50 条
  • [41] ACCURATE MODELING OF FREQUENCY-DEPENDENT TRANSMISSION-LINES IN ELECTROMAGNETIC TRANSIENT SIMULATIONS
    MARTI, JR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (01): : 147 - 157
  • [43] Three-dimensional Accurate modeling of the Microwave Tomography Imaging System
    Sabouni, Abas
    Ostadrahimi, Majid
    Noghanian, Sima
    Pavlovic, Milos
    2011 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (APSURSI), 2011, : 2557 - 2560
  • [44] Accurate Modeling of Variable-Flux PMSMs without Electromagnetic Co-Simulation
    Mirazimi, Maedeh Sadat
    Chen, Chen
    Pescetto, Paolo
    Ferrari, Simone
    Pellegrino, Gianmario
    Diana, Michela
    Thiringer, Torbjorn
    2024 27TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, SPEEDAM 2024, 2024, : 625 - 630
  • [45] Discussion of "Accurate modeling of core-type distribution transformers for electromagnetic transient studies"
    de León, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (02) : 640 - 640
  • [46] Accurate electromagnetic modeling of the die-to-die interconnect link for Gigabit systems applications
    Prokofiev, V
    Shrivastava, UA
    Hill, M
    54TH ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, VOLS 1 AND 2, PROCEEDINGS, 2004, : 1891 - 1894
  • [47] Parametric Anatomical Modeling: a method for modeling the anatomical layout of neurons and their projections
    Pyka, Martin
    Klatt, Sebastian
    Cheng, Sen
    FRONTIERS IN NEUROANATOMY, 2014, 8 : 1 - 18
  • [48] Imaging of Rotation-Symmetric Space Targets Based on Electromagnetic Modeling
    Bai, Xueru
    Bao, Zheng
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2014, 50 (03) : 1680 - 1689
  • [49] Fast electromagnetic modeling and imaging simulation of spacecraft by ground based ISAR
    He, Qing
    Zhang, Yunhua
    Shi, Xiaojin
    2006 7TH INTERNATIONAL SYMPOSIUM ON ANTENNAS, PROPAGATION AND EM THEORY, VOLS 1 AND 2, PROCEEDINGS, 2006, : 879 - 882
  • [50] Adaptive spatial filter and adaptive inverse modeling for electromagnetic source Imaging
    Sekihara, Kensuke
    Hild, Kenneth E., II
    Dalal, Sarang S.
    Timer, Johanna M.
    Wipf, David
    Attias, Hagai T.
    Nagarajan, Srikantan S.
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 117 - +