Requirements for accurate anatomical imaging of the rat for electromagnetic modeling

被引:0
|
作者
Lapin, GD [1 ]
Allen, C [1 ]
机构
[1] ComBioMed Labs, Deerfield, IL 60015 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Modeling electromagnetic energy distribution in laboratory test animals, such as the rat, requires accurate imaging of the animal's anatomy. Accuracy, in this sense, refers to the proper positioning and shape of the various organs of the animal as they are situated in the laboratory setting. A number of factors related to the accuracy of bioelectromagnetic studies dictate the required animal positioning. We performed whole body imaging of Sprague-Dawly rats in an x-ray computed tomography (CT) scanner. By necessity the rats were anesthetized during imaging and a whole body thermoplastic cast was made to support the organs in the same position as they were in an awake rat. Comparisons were made to unsupported anesthetized rats and dead rats. We conclude that it is necessary for rats to be supported in a whole-body cast to best simulate the anatomy of the awake rat. In addition, we note changes in abdominal structures due to death that necessitate the analysis of the animal while it is still alive.
引用
收藏
页码:2480 / 2483
页数:4
相关论文
共 50 条
  • [1] Accurate Electromagnetic Modeling of Melting Hail
    Chobanyan, Elene
    Notaros, Jelena
    Chandrasekar, V.
    Notaros, Branislav
    2013 US NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2013,
  • [2] Fast and Accurate Multiscale Electromagnetic Modeling Framework
    Chew, W. C.
    Cangellaris, A. C.
    Schutt-Aine, J.
    Braunisch, H.
    Qian, Z. G.
    Aydiner, A. A.
    Ayguen, K.
    Jiang, L. J.
    Ma, Z. H.
    Meng, L. L.
    Naeem, M.
    2013 17TH IEEE WORKSHOP ON SIGNAL AND POWER INTEGRITY (SPI), 2013,
  • [3] Accurate Modeling of the Polarizability of Dyes for Electromagnetic Calculations
    Djorovic, Aleksa
    Meyer, Matthias
    Darby, Brendan L.
    Le Ru, Eric C.
    ACS OMEGA, 2017, 2 (05): : 1804 - 1811
  • [4] Histological Validation of Anatomical Imaging for Breast Modeling
    Sen, A.
    Kingsley, C.
    Kulp, A.
    McCulloch, M.
    Willis, B.
    Savannah, K. Brewer
    Contreras, A.
    Bordes, M.
    Huynh, T.
    Fowlkes, N.
    Reece, G.
    Brock, K.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [5] FDTD Modeling for the Accurate Electromagnetic Wave Analysis of Graphene
    Kim, Yeon-Hwa
    Choi, Hongjin
    Cho, Jeahoon
    Jung, Kyung-Young
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (03) : 1281 - 1286
  • [6] FDTD Modeling for the Accurate Electromagnetic Wave Analysis of Graphene
    Yeon-Hwa Kim
    Hongjin Choi
    Jeahoon Cho
    Kyung-Young Jung
    Journal of Electrical Engineering & Technology, 2020, 15 : 1281 - 1286
  • [7] A more accurate electromagnetic modeling of WBG power modules
    Kovacevic-Badstubner, Ivana
    Grossner, Ulrike
    Romano, Daniele
    Antonini, Giulio
    Ekman, Jonas
    PRODCEEDINGS OF THE 2018 IEEE 30TH INTERNATIONAL SYMPOSIUM ON POWER SEMICONDUCTOR DEVICES AND ICS (ISPSD), 2018, : 260 - 263
  • [8] Accurate modeling of underground cable earth impedances for electromagnetic transients
    Uribe, F. A.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 982 - 987
  • [9] Accurate Modeling and Analysis for Electromagnetic Problems with Changeable Geometries and Materials
    Lu, Ze Yuan
    Huang, Xiao Jiao
    Zhang, Li
    Tong, Mei Song
    2021 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2021), 2021, : 535 - 538
  • [10] Computational Optimizations towards an accurate and rapid electromagnetic emission Modeling
    Ramanujan A.
    Riah Z.
    Louis A.
    Mazari B.
    Progress In Electromagnetics Research B, 2011, (27): : 365 - 384