Imaging of peptide adsorption to microfluidic channels in a plastic compact disc using a positron emitting radionuclide

被引:15
|
作者
Lavén, M
Velikyan, I
Djodjic, M
Ljung, J
Berglund, O
Markides, K
Långström, B
Wallenborg, S
机构
[1] Uppsala Univ, Inst Chem, Dept Analyt Chem, S-75124 Uppsala, Sweden
[2] Uppsala Univ, Inst Chem, Dept Organ Chem, S-75124 Uppsala, Sweden
[3] Uppsala Imanet AB, S-75109 Uppsala, Sweden
[4] Gyros AB, S-75183 Uppsala, Sweden
关键词
D O I
10.1039/b418715f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for studying peptide - surface interactions within microfluidic channels by radionuclide imaging is described. With the high surface area-to-volume ratio of channels in miniaturised devices, combined with low amounts of analyte, non-specific peptide adsorption is a critical issue. The objective of the study was therefore to develop a method capable of direct detection of adsorbed peptide within microfluidic channels. A micro-device consisting of channels moulded in a plastic compact disc was chosen for the study, together with two selected peptides of different lengths and isoelectric point (pI) values. A bifunctional chelator, DOTA, was attached to the peptide by conjugation and labelled with the short-lived positron emitting radionuclide Ga-68. Quantitative images of radiotracer distribution within the microfluidic channels were obtained using a PhosphorImager system. The power of the method was demonstrated by the ability to clearly measure changes in adsorption when varying a number of parameters that typically affect peptide adsorption. These included surface modifications, analyte concentration, pH, and ionic strength. Additionally, two quantification methods were developed and compared. Radionuclide imaging also permitted visualisation of adsorption and release processes in microchannel chromatographic columns. The results suggest that radionuclide imaging is a suitable tool not only for the study of peptide adsorption to the microchannels presented in this study but also as a versatile tool to measure peptide - surface interactions in a wide variety of miniaturised structures and devices.
引用
收藏
页码:756 / 763
页数:8
相关论文
共 50 条
  • [21] Monolithic column plastic microfluidic device for peptide analysis using electrospray from a channel opening on the edge of the device
    Liu, Jian
    Ro, Kyung-Won
    Nayak, Ranu
    Knapp, Daniel R.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 259 (1-3) : 65 - 72
  • [22] Real-time imaging and kinetic analysis of cadmium transport in an intact plant using the Positron Emitting Tracer Imaging System (PETIS)
    Fujimaki, S
    Nakamura, S
    Suzui, N
    Ishioka, NS
    Chino, M
    Matsuhashi, S
    PLANT AND CELL PHYSIOLOGY, 2006, 47 : S62 - S62
  • [23] Estimation of phloern flow velocity under cadmium stress using Positron Emitting Tracer Imaging System (PETIS)
    Suzui, Nobuo
    Fujimaki, Shu
    Kawachi, Naoki
    Ishii, Satomi
    Nakamura, Shin-ichi
    Matsuhashi, Shinpei
    PLANT AND CELL PHYSIOLOGY, 2007, 48 : S226 - S226
  • [24] On-chip micropatterning of plastic (cylic olefin copolymer, COC) microfluidic channels for the fabrication of biomolecule microarrays using photografting methods
    Pu, Qiaosheng
    Oyesanya, Olufemi
    Thompson, Bowlin
    Liu, Shantang
    Alvarez, Julio C.
    LANGMUIR, 2007, 23 (03) : 1577 - 1583
  • [25] Real-time whole-plant imaging of 11C translocation using positron-emitting tracer imaging system
    Kawachi, Naoki
    Suzui, Nobuo
    Ishii, Satomi
    Ito, Sayuri
    Ishioka, Noriko S.
    Yamazaki, Haruaki
    Hatano-Iwasaki, Aya
    Ogawa, Ken'ichi
    Fujimaki, Shu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S317 - S320
  • [26] Quantification and imaging of mannitol transport through Caco-2 cell monolayers using a positron-emitting tracer
    Lazorova, L
    Gråsjö, J
    Artursson, P
    Bergström, M
    Wu, F
    Petterman-Bergström, E
    Ögren, M
    Långström, B
    PHARMACEUTICAL RESEARCH, 1998, 15 (07) : 1141 - 1144
  • [27] Measurement of water uptake in a plant using a positron emitting nuclide, 15O with an imaging plate and BGO detectors
    Tanoi, K
    Nakanishi, T
    Hojo, J
    Suzuki, K
    PLANT AND CELL PHYSIOLOGY, 2003, 44 : S48 - S48
  • [28] Quantification and Imaging of Mannitol Transport Through Caco-2 Cell Monolayers Using a Positron-Emitting Tracer
    Lucia Lazorova
    Johan Gråsjö
    Per Artursson
    Mats Bergström
    Feng Wu
    Elisabeth Petterman-Bergström
    Mattias Ögren
    Bengt Långström
    Pharmaceutical Research, 1998, 15 : 1141 - 1144
  • [29] Spatiotemporal in vivo imaging of peptide receptors with high resolution in small animals using positron emission tomography (microPET)
    Johnstroem, P.
    Fryer, T. D.
    Richards, H. K.
    Barret, O.
    Clark, J. C.
    Pickard, J. D.
    Davenport, A. P.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2004, 18 : 74 - 74
  • [30] Combined Positron Emission Tomography and Cerenkov Luminescence Imaging of Sentinel Lymph Nodes Using PEGylated Radionuclide-Embedded Gold Nanoparticles
    Lee, Sang Bong
    Yoon, GhilSuk
    Lee, Sang-Woo
    Jeong, Shin Young
    Ahn, Byeong-Cheol
    Lim, Dong-Kwon
    Lee, Jaetae
    Jeon, Yong Hyun
    SMALL, 2016, 12 (35) : 4894 - 4901