Sensitive electrochemical detection of ciprofloxacin at screen-printed diamond electrodes

被引:48
|
作者
Matsunaga, Tomohiro [1 ]
Kondo, Takeshi [1 ,2 ]
Osasa, Takahiro [3 ]
Kotsugai, Akihiro [3 ]
Shitanda, Isao [1 ,2 ]
Hoshi, Yoshinao [1 ]
Itagaki, Masayuki [1 ,2 ]
Aikawa, Tatsuo [1 ]
Tojo, Toshifumi [1 ]
Yuasa, Makoto [1 ,2 ]
机构
[1] Tokyo Univ Sci, Fac Sci & Technol, Dept Pure & Appl Chem, 2641 Yamazaki, Noda, Chiba 2788510, Japan
[2] Tokyo Univ Sci, Res Inst Sci & Technol, 2641 Yamazaki, Noda, Chiba 2788510, Japan
[3] Ricoh Co Ltd, 2-7-1 Izumi, Ebina, Kanagawa 2430460, Japan
关键词
Electrochemical sensors;
D O I
10.1016/j.carbon.2019.12.051
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study investigates the effect of chemical surface termination on the electrochemical characteristics of boron-doped diamond powder (BDDP). The aim is to realize highly sensitive electrochemical detection of ciprofloxacin (CIP) on BDDP-printed electrodes. To this end, we prepared oxygen-terminated BDDP (O-BDDP) and hydrogen-terminated BDDP (H-BDDP), and mixed them with an insulating polyester (PES) resin binder to obtain BDDP ink for the printed electrode. Scanning electron microscopy of the BDDP-printed electrodes revealed that the O-BDDPs were partially covered with PES resin, while the H-BDDPs were entirely covered with resin. This structural difference might explain the lower charge-transfer resistance of the Ru(NH3)(6)(2+/3+) redox reaction at the O-BDDP-printed electrode than at the H-BDDP-printed electrode. The slope of the calibration curve of the linear sweep voltammogram of CIP was steeper at the O-BDDP-printed electrode than at the H-BDDP-printed electrode and the O-BDD thin-film electrode, and was similar to that at the H-BDD thin-film electrode. Using the O-BDDP-printed electrode, we determined the CIP in artificial buffer-diluted urine in the concentration range 1-30 mu M with a recovery of 107%. We conclude that the O-BDDP-printed electrodes provide a highly sensitive and disposable electrochemical sensor for CIP detection. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:247 / 254
页数:8
相关论文
共 50 条
  • [21] Screen-printed Modified Diamond Electrode for Glucose Detection
    Kondo, Takeshi
    Horitani, Masaru
    Sakamoto, Hironori
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Yuasa, Makoto
    CHEMISTRY LETTERS, 2013, 42 (04) : 352 - 354
  • [22] An electrochemical signal switch–based (on–off) aptasensor for sensitive detection of insulin on gold-deposited screen-printed electrodes
    Samet Şahin
    Şevval Kaya
    Zafer Üstündağ
    Mustafa Oguzhan Caglayan
    Journal of Solid State Electrochemistry, 2022, 26 : 907 - 915
  • [23] Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens
    Vasilescu, Alina
    Nunes, Gilvanda
    Hayat, Akhtar
    Latif, Usman
    Marty, Jean-Louis
    SENSORS, 2016, 16 (11)
  • [24] Characterisation of Screen-Printed Electrodes for Detection of Heavy Metals
    I. Palchetti
    A. Cagnini
    M. Mascini
    A. P. F. Turner
    Microchimica Acta, 1999, 131 : 65 - 73
  • [25] Characterisation of screen-printed electrodes for detection of heavy metals
    Palchetti, I
    Cagnini, A
    Mascini, M
    Turner, APF
    MIKROCHIMICA ACTA, 1999, 131 (1-2) : 65 - 73
  • [26] SCREEN-PRINTED ELECTRODES MADE ON STONE PAPER SUBSTRATE FOR URIC ACID ELECTROCHEMICAL DETECTION
    Varodi, Codruta
    Pogacean, Florina
    Gheorghe, Marin
    Barbu-Tudoran, Lucian
    Pruneanu, Stela
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2020, 65 (02): : 233 - 242
  • [27] Electrochemical Detection of Glyphosate in Surface Water Samples Based on Modified Screen-Printed Electrodes
    Geana, Elisabeta-Irina
    Ciucure, Corina Teodora
    Soare, Amalia
    Enache, Stanica
    Ionete, Roxana Elena
    Dinu, Livia Alexandra
    NANOMATERIALS, 2024, 14 (11)
  • [28] Evaluation of electrochemical, UV/VIS and Raman spectroelectrochemical detection of Naratriptan with screen-printed electrodes
    Navarro Hernandez, Carla
    Martin-Yerga, Daniel
    Begona Gonzalez-Garcia, Maria
    Hernandez-Santos, David
    Fanjul-Bolado, Pablo
    TALANTA, 2018, 178 : 85 - 88
  • [29] Biocompatible carbon-based screen-printed electrodes for the electrochemical detection of nitric oxide
    Miserere, S
    Ledru, S
    Ruillé, N
    Griveau, S
    Boujtita, M
    Bedioui, F
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (02) : 238 - 244
  • [30] Screen-printed amalgam electrodes
    Josypcuk, Bohdan
    Langmaier, Jan
    Tvorynska, Sofiia
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 347