Active-passive gradient shielding for MRI acoustic noise reduction

被引:52
|
作者
Edelstein, WA
Kidane, TK
Taracila, V
Baig, TN
Eagan, TP
Cheng, YCN
Brown, RW
Mallick, JA
机构
[1] MRSci LLC, Schenectady, NY 12309 USA
[2] Univ Texas, Inst Adv Technol, Austin, TX 78712 USA
关键词
acoustics; acoustic noise; acoustic noise reduction; noise reduction; MRI acoustic noise; MRI acoustic noise reduction; gradients; active shielding; actively shielded gradients; active-passive shielding;
D O I
10.1002/mrm.20472
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An important source of MRI acoustic noise-magnet cryostat warm-bore vibrations caused by eddy-current-induced forces-can be mitigated by a passive metal shield mounted on the outside of a vibration-isolated, vacuum-enclosed shielded gradient set. Finite-element (FE) calculations for a z-gradient indicate that a 2-mm-thick Cu layer wrapped on the gradient assembly can decrease mechanical power deposition in the warm bore and reduce warm-bore acoustic noise production by about 25 dB. Eliminating the conducting warm bore and other magnet parts as significant acoustic noise sources could lead to the development of truly quiet, fully functioning MRI systems with noise levels below 70 dB. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1013 / 1017
页数:5
相关论文
共 50 条
  • [41] MRI acoustic noise reduction by application of passive screening materials in the MR-scanner and the MR suite
    Moelker, A
    Vogel, MW
    Pattynama, PM
    RADIOLOGY, 2002, 225 : 189 - 189
  • [42] Active-passive Transition of Metals.
    Lorbeer, P.
    Juettner, K.
    Lorenz, W.J.
    Werkstoffe und Korrosion, 1983, 34 (06): : 290 - 294
  • [43] ACTIVE-PASSIVE IMMUNIZATION AGAINST TETANUS
    BISTONI, F
    MOSCI, L
    VECCHIARELLI, A
    MARCONI, P
    PITZURRA, M
    ANNALI SCLAVO, 1977, 19 (05): : 1006 - 1012
  • [44] Tikhonov Regularization Approach for Acoustic Noise Reduction in an Asymmetric, Self-Shielded MRI Gradient Coil
    Jackson, James M.
    Brideson, Michael A.
    Forbes, Larry K.
    Crozier, Stuart
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2010, 37B (03) : 167 - 179
  • [45] Shaping and Timing Gradient Pulses to Reduce MRI Acoustic Noise
    Segbers, Marcel
    Sierra, Carlos V. Rizzo
    Duifhuis, Hendrikus
    Hoogduin, Johannes M.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 546 - 553
  • [46] Acoustic noise reduction in a 4 T MRI scanner
    Mechefske, CK
    Geris, R
    Gati, JS
    Rutt, BK
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 13 (03) : 172 - 176
  • [47] A Structure Design Method for Reduction of MRI Acoustic Noise
    Nan, Jiaofen
    Zong, Nannan
    Chen, Qiqiang
    Zhang, Liangliang
    Zheng, Qian
    Xia, Yongquan
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2017, 2017
  • [48] Acoustic noise reduction in a 4 T MRI scanner
    Chris K. Mechefske
    Ryan Geris
    Joseph S. Gati
    Brian K. Rutt
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2001, 13 (3) : 172 - 176
  • [49] Hybrid Active-Passive Shielding of Magnetic Field of Overhead Power Lines with Triangular Phase Conductors Arrangements
    Kuznetsov, B. I.
    Kutsenko, A. S.
    Nikitina, T. B.
    Bovdui, I. V.
    Chunikhin, K. V.
    Dobrodeyev, P. N.
    PROBLEMELE ENERGETICII REGIONALE, 2023, (03): : 1 - 16
  • [50] ON THE REDUCTION OF THE HVAC NOISE USING ACTIVE AND PASSIVE NOISE CONTROL TECHNOLOGIES
    Shige, Koki
    Terashima, Osamu
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 1, 2023,