A comprehensive study on the kinetic aspects and experimental design for the voltammetric response of a Sn(IV)-clinoptilolite carbon paste electrode towards Hg(II)

被引:125
|
作者
Tamiji, Tahmineh [1 ,2 ]
Nezamzadeh-Ejhieh, Alireza [1 ]
机构
[1] Islamic Azad Univ, Shahreza Branch, Dept Chem, POB 311-86145, Shahreza, Isfahan, Iran
[2] Islamic Azad Univ, Young Researchers & Elite Club, Shahreza Branch, Shahreza, Iran
关键词
Kinetic constant; RSM; Zeolite modified electrode; Clinoptilolite nanoparticles; Chronoamperometry; Mercury(II); NANOCOMPOSITE-MODIFIED ELECTRODE; ZEOLITE-MODIFIED ELECTRODES; ELECTROCHEMICAL DETECTION; GRAPHENE OXIDE; MERCURY II; PHOTOCATALYTIC DEGRADATION; IONS; POLYPYRROLE; OXIDATION; SURFACE;
D O I
10.1016/j.jelechem.2018.10.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Sn(IV) ion exchanged clinoptilolite nanoparticles (Sn(IV)-CNP) were used as a modifier for the modification of carbon paste electrode (CPE). When the modified electrode was immersed in HCl supporting electrolyte, Sn (IV) cations can locate at the Sn(IV)-CNP-CPE electrode surface via an ion exchange process with protons of the supporting electrolyte. These electroactive cations underwent a redox process at the electrode surface. Increased peak current of Sn(IV) reduction by adding Hg(II) analyte into the supporting electrolyte solution was used for the voltammetric determination of Hg(II). Focus of the work was on study of the interaction effects between the influencing variables in square wave voltammetric response of the modified electrode in the presence of Hg(II) cations by designing the experiments (via response surface methodology: RSM) and study of some kinetic aspects of the process in linear sweep voltammetry and chronoamperometry. The optimal run in RSM was obtained in: Csn((IV)) in ion exchange solution: 0.37 mol L-1, modifier%: 22.45, amplitude: 60 mV and step potential: 2.9 mV. The response current of the modified electrode was proportion to Hg(II) concentration in the range of 0.1-10 mu M (DL: 0.05 mu M) in square wave voltammetry and in the range of 0.1-10 mu M (DL: 0.01 mu M) in chronoamperometry. Using the Tafel plots, the values of alpha and k(o) were determined for the modified electrode as 0.298, 1.91 x 10(-3) s(-1) and 0.311, 6.62 x 10(-3) s(-1) in the absence and presence of Hg(II) cations, respectively.
引用
收藏
页码:95 / 105
页数:11
相关论文
共 40 条
  • [31] Efficient solid amino acid-clinoptilolite nanoparticles adsorbent for Mn(II) removal: A comprehensive study on designing the experiments, thermodynamic and kinetic aspects
    Mehrali-Afjani, Meymanat
    Nezamzadeh-Ejhieh, Alireza
    SOLID STATE SCIENCES, 2020, 101
  • [32] Square Wave Anodic Stripping Voltammetric Determination of Hg(II) with N-1-hydroxy-N-1,N-2-diphenylbenzamidine Modified Carbon Paste Electrode
    Tesfaye, Endale
    Chandravanshi, Bhagwan Singh
    Hailu, Tesfu
    Negash, Negussie
    Tessema, Merid
    ELECTROANALYSIS, 2022, 34 (05) : 892 - 903
  • [33] Sol-gel Immobilized Horseradish Peroxidase Modified Carbon Paste Electrode towards the Determination of Hydroquinone in Non-Aqueous Solvents: A Voltammetric Study
    Reddaiah, Kasetty
    Reddy, Tukiakula Madhusudana
    Raghu, Pamula
    Gopal, Palla
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (04): : 372 - 385
  • [34] Carbon paste electrode modified with the copper(II) complex of N-benzoyl-N′,N′-di-N-butyl-thiourea -: Voltammetric behavior and response to copper(II)
    Lubert, Karl-Heinz
    Beyer, Lothar
    SOLVENT EXTRACTION AND ION EXCHANGE, 2008, 26 (03) : 321 - 331
  • [35] Structure-switching of an organothiol neutral carrier by gold nanoparticles decorated on SH-MWCNTs for ultra-trace voltammetric assay of Hg(II) using a carbon paste electrode
    Ramezani, Soleyman
    Mashhadizadeh, Mohammad Hossein
    Jalilian, Sajad
    Aghili, Mehdi
    ANALYTICAL METHODS, 2015, 7 (18) : 7765 - 7775
  • [36] Removal of Hg (II) from Aqueous Solution on Powdered Coal-Based Activated Carbon: Experimental Design of Microwave Assisted Preparation, Equilibrium and Kinetic Study
    Li, Deqiang
    Ma, Xinfang
    Yan, Jiayu
    Wu, Zhansheng
    Liu, Zhiyong
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2015, 37 (06): : 1088 - 1098
  • [37] Voltammetric identification of lead(II) and (IV) in mediaeval glazes in abrasion-modified carbon paste and polymer film electrodes.: Application to the study of alterations in archaeological ceramic
    Doménech-Carbó, A
    Doménech-Carbó, MT
    Gimeno-Adelantado, JV
    Moya-Moreno, M
    Bosch-Reig, F
    ELECTROANALYSIS, 2000, 12 (02) : 120 - 127
  • [38] Optimization of stripping voltammetric sensor by mixture design-artificial neural network-genetic algorithm for determination of trace copper(II) based on iodoquinol-carbon nanotube modified carbon paste electrode
    Nezhadali, Azizollah
    Sadeghzadeh, Samira
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 : 134 - 142
  • [39] Experimental study of the effect of undoped ZnO, Fe and Mn doped ZnO nanostructures and the electrochemical response of the nanostructures modified carbon paste electrode toward Levodopa
    Nia, Bahram Hosseini
    Firooz, Azam Anaraki
    Ghalkhani, Masoumeh
    Beheshtian, Javad
    IRANIAN CHEMICAL COMMUNICATION, 2016, 4 (04) : 483 - 492
  • [40] A comprehensive study on removal of cadmium from aqueous solution by using mesoporous SBA-15 functionalized by 1,5-diphenyl carbazide: experimental design, kinetic, thermodynamic, and isotherm aspects
    Danesh-Khorasgani, Maryam
    Faghihian, Hossein
    Givianrad, Mohammad Hadi
    Aberoomand-Azar, Parviz
    Saber-Tehrani, Mohammad
    COMPTES RENDUS CHIMIE, 2021, 24 (02) : 43 - 59