Experimental evaluation of validity of simplified Monte Carlo method in proton dose calculations

被引:33
|
作者
Kohno, R
Takada, Y
Sakae, T
Terunuma, T
Matsumoto, K
Nohtomi, A
Matsuda, H
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba, Ibaraki 3058575, Japan
[2] Univ Tsukuba, Proton Med Res Ctr, Tsukuba, Ibaraki 3058575, Japan
[3] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 10期
关键词
D O I
10.1088/0031-9155/48/10/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is important for proton therapy to calculate dose distributions accurately in treatment planning. Dose calculations in the body for treatment planning are converted to dose distributions in water, and the converted calculations are then generally evaluated by the dose measurements in water. In this paper, proton dose calculations were realized for a phantom simulating a clinical heterogeneity. Both dose calculations in the phantom calculated by two dose calculation methods, the range-modulated pencil beam algorithm (RMPBA) and the simplified Monte Carlo (SMC) method, and dose calculations converted to dose distributions in water by the same two methods were verified experimentally through comparison with measured distributions, respectively. For the RMPBA, though the converted calculations in water agreed moderately well with the measured ones, the calculated results in the actual phantom produced large errors. This meant that dose calculations in treatment planning should be evaluated by the dose measurements not in water but in the body with heterogeneity. On the other hand, the results calculated in the phantom, even by the less rigorous SMC method, reproduced the experimental ones well. This finding showed that actual dose distributions in the body should be predicted by the SMC method.
引用
收藏
页码:1277 / 1288
页数:12
相关论文
共 50 条
  • [31] Extension of a numerical algorithm to proton dose calculations .1. Comparisons with Monte Carlo simulations
    Sandison, GA
    Lee, CC
    Lu, XY
    Papiez, LS
    MEDICAL PHYSICS, 1997, 24 (06) : 841 - 849
  • [32] ABSORBED DOSE MEASUREMENTS AT AN 800 GEV PROTON ACCELERATOR - COMPARISON WITH MONTE-CARLO CALCULATIONS
    COSSAIRT, JD
    BUTALA, SW
    GERARDI, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 238 (2-3): : 504 - 508
  • [33] ABSORBED DOSE MEASUREMENTS AT AN 800 GEV PROTON ACCELERATOR - COMPARISON WITH MONTE-CARLO CALCULATIONS
    COSSAIRT, JD
    BUTALA, SW
    GERARDI, MA
    HEALTH PHYSICS, 1985, 49 (01): : 153 - 153
  • [34] A simplified positron elastic scattering model for Monte Carlo calculations
    Chaoui, Zine-El-Abidine
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2006, 18 (45) : 10303 - 10312
  • [35] Monte Carlo dose calculations for dynamic IMRT treatments
    Keall, PJ
    Siebers, JV
    Arnfield, M
    Kim, JO
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 929 - 941
  • [36] Monte Carlo calculations of radiotherapy dose in "homogeneous" anatomy
    Kairn, Tanya
    Livingstone, Alexander G.
    Crowe, Scott B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 156 - 165
  • [37] GPU-oriented Monte Carlo dose calculations
    Ziegenhein, P.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S87 - S87
  • [38] Effect of voxel size on Monte Carlo dose calculations
    Qin, L
    Yang, J
    Li, J
    Chen, L
    Price, R
    Ma, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1883 - 1883
  • [39] MONTE CARLO CALCULATIONS OF GAMMA-RAY DOSE
    BROWNELL, GL
    REDDY, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (04): : 616 - &
  • [40] Development of a Monte Carlo model for dose calculations in IMRT
    Aaronson, R
    DeMarco, J
    Chetty, I
    Solberg, T
    MEDICAL PHYSICS, 2003, 30 (06) : 1330 - 1330