Experimental and numerical investigation on withdrawal connectors usage for lateral resistance of timber shear walls structure

被引:2
|
作者
Shao, Feng [1 ]
Wang, Yanshang [2 ]
Lian, Wu [3 ]
Benjeddou, Omrane [4 ]
机构
[1] Qingdao Univ Technol, Coll Architecture & Urban Planning, Qingdao 266033, Shandong, Peoples R China
[2] Qingdao Fire Rescue Detachment, Qingdao 266000, Shandong, Peoples R China
[3] Civil Engn Fabr Technol Dev Co Ltd, Zhengzhou 450001, Peoples R China
[4] Prince Sattam bin Abdulaziz Univ, Coll Engn, Dept Civil Engn, Alkharj 16273, Saudi Arabia
来源
JOURNAL OF BUILDING ENGINEERING | 2021年 / 44卷 / 44期
关键词
Kinematic model; Ply-lam; Connector; Shear wall; Lateral resistance; FRAME WOOD BUILDINGS; MECHANICAL-PROPERTIES; WOODFRAME STRUCTURES; 3-DIMENSIONAL MODEL; SEISMIC ANALYSIS; BEHAVIOR; STRENGTH; CLT;
D O I
10.1016/j.jobe.2021.103266
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) is a feasible option for mid-rise structures in the United States and Canada. United States building standards require that CLT be designed for seismic applications using alternative methods. CLT as a novel structural system is introduced in this paper, using experimental, nonlinear numerical model and kinematic formulation of CLT to examine the effects of models characteristics on CLT performance. In this study, finite element (FE) and kinematic model of CLT panels were constructed. For evaluating the preciseness of the FE model, test data of CLT panels was used. The mechanical characteristics of connections were used to estimate lateral resistances, which were then compared to experimental data. Thus, 4 out of 7 shear wall specimens included withdrawal connectors and one Ply-lam panel. A single panel was split in half in three of the seven shear wall examples. They were basically linked by 2 or 4 connections to make a single panel. The Ply-lam wall-to-floor connections had two or four connectors, and the vertical load was 0, 24 and 120 kN. Therefore, by using kinematic models. The tested data were 6.3-52.7% more than the predicted value. There was a 10% maximum error of maximum shear forces of panels in the finite element analysis which was considerably closer to the test findings. It indicates that the connector's behavior may be used to accurately anticipate the lateral resistance.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Lateral resistance of strapped wood shear walls
    Shadravan, Shideh
    Ramseyer, Christopher C.
    Floyd, Royce W.
    JOURNAL OF STRUCTURAL INTEGRITY AND MAINTENANCE, 2019, 4 (02) : 65 - 75
  • [32] Experimental and Numerical Investigation on the Behaviour of Precast Concrete Sandwich Panels with Different Shear Connectors
    Ahmadi A.D.
    Torabi A.
    Totonchi A.
    Safari D.
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2024, 48 (5) : 3087 - 3102
  • [33] Experimental study on lateral performance of glued-laminated timber frame infilled with cross-laminated timber shear walls
    Xue, Jianyang
    Ren, Guoqi
    Qi, Liangjie
    Wu, Chenwei
    Yuan, Zhen
    ENGINEERING STRUCTURES, 2021, 239
  • [34] Numerical and experimental investigation of the hygrothermal response of timber frame walls with an exterior air barrier
    Langmans, Jelle
    Klein, Ralf
    Roels, Staf
    JOURNAL OF BUILDING PHYSICS, 2013, 36 (04) : 375 - 397
  • [35] Reinforcement Effects and Parametric Study of the Lateral Response of Multilayered Wood-Frame Shear Walls: An Experimental and Numerical Investigation
    Valdivieso, D.
    Lopez-Garcia, D.
    Liel, A.
    Guindos, P.
    JOURNAL OF STRUCTURAL ENGINEERING, 2025, 151 (02)
  • [36] Experimental investigation and numerical modeling of rocking cross laminated timber walls on a flexible foundation
    Wichman, Sarah
    Berman, Jeffrey W.
    Pei, Shiling
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2022, 51 (07): : 1697 - 1717
  • [37] TIMBER SHEAR WALLS: NUMERICAL ASSESSMENT OF THE EQUIVALENT VISCOUS DAMPING
    Di Gangi, Giorgia
    Demartino, Cristoforo
    Quaranta, Giuseppe
    Vailati, Marco
    Monti, Giorgio
    IRF2018: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON INTEGRITY-RELIABILITY-FAILURE, 2018, : 641 - 650
  • [38] Lateral performance of midply wood shear walls with anchor tie-down system: Experimental investigation and numerical simulation
    Guo, Suyi
    He, Minjuan
    Li, Zheng
    Liang, Feng
    Chen, Fei
    Sun, Yongliang
    Briseghella, Bruno
    He, Guirong
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 235
  • [39] Experimental Investigation on Lateral Performance of Timber-Steel Hybrid Shear Wall Systems
    He, Minjuan
    Li, Zheng
    Lam, Frank
    Ma, Renle
    Ma, Zhong
    JOURNAL OF STRUCTURAL ENGINEERING, 2014, 140 (06)
  • [40] Numerical Investigation into Headed Shear Connectors under Fire
    Wang, Aaron J.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2012, 138 (01): : 118 - 122