Relationship between meibomian gland loss in infrared meibography and meibum quality in dry eye patients

被引:6
|
作者
Ha, Minji [1 ,2 ]
Oh, Si-Eun [1 ]
Whang, Woong-Joo [1 ,2 ]
Na, Kyung-Sun [1 ,2 ]
Kim, Eun Chul [1 ]
Kim, Hyun-Seung [1 ]
Kim, Jin Soo [3 ]
Hwang, Ho Sik [1 ,2 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Ophthalmol, 222 Banpo Daero, Seoul, South Korea
[2] Catholic Univ Korea, Yeouido St Marys Hosp, Dept Ophthalmol, 10,63 Ro, Seoul 07345, South Korea
[3] Hallym Univ, Chuncheon Sacred Heart Hosp, Dept Ophthalmol, 77 Sakju Ro, Chuncheon Si, Gangwon Do, South Korea
基金
新加坡国家研究基金会;
关键词
Meibum; Meibum quality; Meibomian gland dysfunction; Dry eye disease; Meiboscore; INTERNATIONAL WORKSHOP; DYSFUNCTION REPORT; DEFINITION; MORPHOLOGY; DISEASE;
D O I
10.1186/s12886-022-02509-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background In the present study, we evaluated the correlation between meibomian gland dropout and meibum quality in the same central 8 meibomian glands of the eyelid. Methods Ninety-nine eyes of 91 patients with dry eye were included in the study. Dropout of the 8 central meibomian glands of the eyelids was graded as 0, 1, 2, or 3, according to the dropout area. The meibum quality was graded as follows: grade 0, no secretion; 1, inspissated/toothpaste consistency; 2, cloudy liquid secretion; and 3, clear liquid secretion. For 68 eyes of 68 patients, correlation analysis between dropout and meibum quality was performed. To precisely analyze the direct correlation between meibomian gland dropout in meibography and meibum quality, we evaluated 31 eyes of 23 patients with focal dropout in meibography. Results The median (interquartile range) meiboscore was 1.0 (2.0) in the upper eyelids and 0.0 (1.0) in the lower eyelids. The median (interquartile range) meibum quality grade was 3.0 (1.0) in the upper eyelids and 1.0 (1.0) in the lower eyelids. No significant correlation between the meiboscore and meibum quality grade was detected in the upper (p =0.746) or lower (p =0.551) eyelids. Analysis of the direct correlation between meibomian gland dropout in meibography and meibum quality in patients with focal dropout (loss of 1 or 2 adjacent meibomian glands), however, indicated that meibomian glands with dropout secreted little to no meibum. Conclusions Overall analysis revealed no relationship between meibomian gland dropout and meibum quality, but more detailed investigation of each meibomian gland alone revealed that meibomian glands with dropout secrete little to no meibum.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Relationship between ocular surface temperature and 0.1% cyclosporine a in dry eye syndrome with meibomian gland dysfunction
    Lee, Donghun
    Lee, Geun Woo
    Yoon, Sook Hyun
    PLOS ONE, 2023, 18 (11):
  • [32] Association Between Tear Osmolarity and Dry Eye Signs in Patients with Obstructive Meibomian Gland Dysfunction
    Choi, Han Sol
    Lee, Si Hyung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1183 - 1190
  • [33] Correlation Study Between Abnormal Morphology of Meibomian Glands and Meibum in Patients With Dry Eye Disease Under in vivo Confocal Microscopy
    Zheng, Qian
    Xue, Yuanyuan
    Zhong, Xiaowei
    Li, Guangwei
    Shi, Weiyun
    Wang, Ting
    FRONTIERS IN MEDICINE, 2022, 8
  • [34] The Relationship of Punctocanthal Epitheliopathy and Lid Wiper Epitheliopathy in Symptomatic Dry Eye Patients with Meibomian Gland Dysfunction
    Rojas, Kevin
    Greiner, Jack
    Glonek, Thomas
    Oliver, Paula
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [35] Clinical Dry Eye and Meibomian Gland Features Among Dry Eye Patients in Rural and Urban Ghana
    Osae, Eugene Appenteng
    Ablordeppey, Reynolds Kwame
    Horstmann, Jens
    Kumah, David Ben
    Steven, Philipp
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 4055 - 4063
  • [36] Evaluation of Meibomian gland dysfunction using meibography in patients with xeroderma pigmentosum
    Marcos, Allexya Affonso Antunes
    Freitas, Denise
    Hazarbassanov, Rossen Mihaylov
    Fernandes, Arthur Gustavo
    Castro, Ligia Pereira
    de Melo, Danilo Batista Vieira
    Menck, Carlos F. Martins
    Morales, Melina Correia
    Gomes, Jose Alvaro Pereira
    Neto, Rubens Belfort
    Singh, Arun D.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2024, 87 (02)
  • [37] A simple technique of meibography for morphological and functional evaluation of meibomian glands in dry eye conditions
    Mounika, Vala
    Kamath, Sumana J.
    Tejaswi, Pagadala
    Kamath, Ajay R.
    Rodrigues, Gladys R.
    Mendonca, Teena Mariet
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (04) : 1420 - 1425
  • [38] EFFECTS OF IPL AND RF ON MEIBOMIAN GLAND HEALTH IN THE FACE OF DRY EYE AND MEIBOMIAN GLAND DYSFUNCTION
    Jo, Jason
    Tan, John
    Chelnis, James
    LASERS IN SURGERY AND MEDICINE, 2023, 55 : S47 - S48
  • [39] Evaluation of dry eye and meibomian gland function in pregnancy
    Kunduraci, Merve Sena
    Kockar, Alev
    Helvacioglu, Caglar
    Kirik, Furkan
    Hacioglu, Gulay Karakus
    Akcay, Betul Ilkay Sezgin
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4263 - 4269
  • [40] OCULAR EVAPORATION IN MEIBOMIAN GLAND DYSFUNCTION AND DRY EYE
    MATHERS, WD
    OPHTHALMOLOGY, 1993, 100 (03) : 347 - 351