Wear and Loosening in Total Knee Arthroplasty: A Quick Review

被引:23
|
作者
Fraser, James F. [1 ]
Werner, Steven [2 ]
Jacofsky, David J. [3 ]
机构
[1] Banner Good Samaritan Hosp, Dept Orthoped, Phoenix, AZ 85006 USA
[2] Ctr Orthoped Res & Educ, CORE Inst, Div Adult Reconstruct, Phoenix, AZ USA
[3] CORE Inst, Ctr Orthoped Res & Educ, Phoenix, AZ USA
关键词
wear; osteolysis; bone defects; revision total knee arthroplasty; TIBIAL BONE LOSS; FOLLOW-UP; JOINT ARTHROPLASTY; MOBILE-BEARING; REVISION; OSTEOLYSIS; POLYETHYLENE; METAANALYSIS; REPLACEMENT; FIXATION;
D O I
10.1055/s-0034-1398375
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Wear and osteolysis are common problems that often require revision surgery following total knee arthroplasty (TKA). Wear rates can be reduced through proper implant positioning and the use of modern, highly cross-linked polyethylene liners. More research is needed to identify medications that could prevent or treat the bone loss associated with osteolysis. Bone defects resulting from osteolysis can be managed with a variety of bone-preserving strategies and often require the use of structural augmentation, either in the form of bulk allografts or metal augments. Recently, porous metal augments such as tantalum cones have gained popularity among surgeons performing revision TKA for osteolytic bone defects with promising early clinical results. A megaprosthesis with a rotating hinge device may be used in salvage cases for severe bone deficiencies.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [21] Prediction of total knee arthroplasty polyethylene wear using the wear index
    Miura, H
    Higaki, H
    Nakanishi, Y
    Mawatari, T
    Moro-oka, T
    Murakami, T
    Iwamoto, Y
    JOURNAL OF ARTHROPLASTY, 2002, 17 (06): : 760 - 766
  • [22] The causes of insert backside wear in total knee arthroplasty
    Wasielewski, RC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) : 232 - 246
  • [23] Factors affecting polyethylene wear in total knee arthroplasty
    Kuster, MS
    Stachowiak, GW
    ORTHOPEDICS, 2002, 25 (02) : S235 - S242
  • [24] EFFECT OF POLYETHYLENE QUALITY ON WEAR IN TOTAL KNEE ARTHROPLASTY
    TANNER, MG
    WHITESIDE, LA
    WHITE, SE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 83 - 88
  • [25] The influence of slip velocity on wear of total knee arthroplasty
    Schwenke, T
    Borgstede, LL
    Schneider, E
    Andriacchi, TP
    Wimmer, MA
    WEAR, 2005, 259 : 926 - 932
  • [26] WEAR AND DEFORMATION OF PATELLAR COMPONENTS IN TOTAL KNEE ARTHROPLASTY
    HSU, HP
    WALKER, PS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (246) : 260 - 265
  • [27] Poor outcomes of revision total knee arthroplasty in patients with septic loosening compared to patients with aseptic loosening
    Baek, Ji-Hoon
    Lee, Su Chan
    Jin, Hosun
    Kim, Jin-Woo
    Ahn, Hye Sun
    Nam, Chang Hyun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [28] OUTPATIENT TOTAL HIP ARTHROPLASTY, TOTAL KNEE ARTHROPLASTY, AND UNICOMPARTMENTAL KNEE ARTHROPLASTY A Systematic Review of the Literature
    Pollock, Michael
    Somerville, Lyndsay
    Firth, Andrew
    Lanting, Brent
    JBJS REVIEWS, 2016, 4 (12)
  • [29] Poor outcomes of revision total knee arthroplasty in patients with septic loosening compared to patients with aseptic loosening
    Ji-Hoon Baek
    Su Chan Lee
    Hosun Jin
    Jin-Woo Kim
    Hye Sun Ahn
    Chang Hyun Nam
    Journal of Orthopaedic Surgery and Research, 16
  • [30] Infected total knee arthroplasty: Review
    Berman, AT
    Schendel, TE
    ORTHOPEDICS, 1997, 20 (06) : 563 - &