摘要
This study deals with the exergetic performance assessment of a combined heat and power (CHP) system installed in Eskisehir city of Turkey. Quantitative exergy balance for each component and the whole CHP system was considered, while exergy consumptions in the system were determined. The performance characteristics of this CHP system were evaluated using exergy analysis method. The exergetic efficiency of the CHP system was accounted for 38.16% with 49 880 kW as electrical products. The exergy consumption occurred in this system amounted to 80 833.67 kW. The ways of improving the exergy efficiency of this system were also analysed. As a result of these, a simple way of increasing the exergy efficiency of the available CHP system was suggested that the valves-I-III and the MPSC could be replaced by a 3500 kW-intermediate pressure steam turbine (IPST). If the IPST is installed to the CHP system (called the modified CHP (MCHP) system), the exergetic efficiency of the MCHP system is calculated to be 40.75% with 53 269.53 kW as electrical products. The exergy consumption is found to be 77 444.14 kW in the MCHP system. Copyright (C) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:849 / 866
页数:18
相关论文
共 50 条
  • [21] An analysis of SOFC/GT CHP system based on exergetic performance criteria
    Akkaya, Ali Volkan
    Sahin, Bahri
    Erdem, Hasan Huseyin
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (10) : 2566 - 2577
  • [22] Energetic and exergetic efficiencies of coal-fired CHP (combined heat and power) plants used in district heating systems of China
    Liao, Chunhui
    Ertesvag, Ivar S.
    Zhao, Jianing
    ENERGY, 2013, 57 : 671 - 681
  • [23] Fundamental aspects of combined heat and power (CHP) plants
    BWK- Energie-Fachmagazin, 2021, 73 (5-6): : 56 - 57
  • [24] Relevance of combined heat and power production (CHP) with biomass
    Dienhart, H
    Nitsch, J
    BIOMASS FOR ENERGY AND INDUSTRY, 1998, : 1460 - 1463
  • [25] Ship HVAC - Is combined heat and power (CHP) practical?
    Giles, J.
    International Symposium on Marine Design, 2006, : 95 - 101
  • [26] Exergetic and exergoeconomic evaluation of a solid-oxide fuel-cell-based combined heat and power generation system
    Lee, Young Duk
    Ahn, Kook Young
    Morosuk, Tatiana
    Tsatsaronis, George
    ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 154 - 164
  • [27] Thermodynamic evaluation of CHP (combined heat and power) plants integrated with installations of coal gasification
    Ziebik, Andrzej
    Malik, Tomasz
    Liszka, Marcin
    ENERGY, 2015, 92 : 179 - 188
  • [28] Performance analysis of the coal-fired power plant with combined heat and power (CHP) based on absorption heat pumps
    Zhang, H. S.
    Zhao, H. B.
    Li, Z. L.
    JOURNAL OF THE ENERGY INSTITUTE, 2016, 89 (01) : 70 - 80
  • [29] Performance comparison of multi-objective evolutionary algorithms for exergetic and exergoenvironomic optimization of a benchmark combined heat and power system
    Nondy, J.
    Gogoi, T. K.
    ENERGY, 2021, 233
  • [30] Performance comparison of multi-objective evolutionary algorithms for exergetic and exergoenvironomic optimization of a benchmark combined heat and power system
    Nondy, J.
    Gogoi, T.K.
    Energy, 2021, 233