Development of single copper feeder messenger wire for overhead contact lines

被引:0
|
作者
Iwainaka, A [1 ]
Suzuki, A [1 ]
Shimodaira, Y [1 ]
机构
[1] Railway Tech Res Inst, Tokyo, Japan
来源
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Feeder messenger wire type overhead contact lines are drawing attention recently from the viewpoint of laborsaving for maintenance. Those that use two PH356mm(2) messenger wires are introduced in Tokyo, and those that use an SB-TACSR730mm(2) messenger wire are in the Kansai district. Regarding the number of messenger wires, the one-wire system is more advantageous, as it invokes a smaller number of parts. As the material for the wire, copper is more advantageous than aluminum, since it does not require connection with different metals. To realize the advantages of the two systems, therefore, we developed a feeder messenger wire type overhead contact line which has only one copper messenger wire.
引用
收藏
页码:703 / 712
页数:10
相关论文
共 50 条
  • [31] Development of low-cost contact wire for high-speed lines
    Usuki T.
    Yamashita C.
    Sugahara A.
    Ohara T.
    Nakamoto H.
    Ikeda K.
    Quarterly Report of RTRI (Railway Technical Research Institute), 2021, 62 (02) : 98 - 103
  • [32] Lightning Induced Voltage Characteristics of Overhead Single Wire
    Yu J.
    Geng Y.
    Fan Y.
    Wang J.
    Lu Z.
    Cai X.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (09): : 2911 - 2918
  • [33] Laboratory Assessment of ARC Damage in Railway Overhead Contact Lines With a Case Study on Copper-Silver and Low Oxygen Content Copper
    Sunar, Ozgun
    Fletcher, David
    Beagles, Adam
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (05) : 3074 - 3081
  • [34] STUDY ON APPLICATION OF COPPER CLAD STEEL WIRE TO CONTACT WIRE
    NAGASAWA, H
    AOKI, S
    TAKAYAMA, T
    JOURNAL OF JAPANESE SOCIETY OF TRIBOLOGISTS, 1991, 36 (05) : 395 - 402
  • [35] Calculation of active power losses in the grounding wire of overhead power lines
    Krasnozhon A.V.
    Buinyi R.O.
    Pentegov I.V.
    1600, Institute of Electrodynamics, National Academy of Sciences of Ukraine (2016): : 23 - 25
  • [36] Failure risk due to lightning strokes to overhead contact lines
    Biesenack, Hartmut
    Dölling, André
    Schmieder, Axel
    eb - Elektrische Bahnen, 2006, 104 (04): : 182 - 189
  • [37] A Survey on Automatic Inspections of Overhead Contact Lines by Computer Vision
    Yu, Long
    Gao, Shibin
    Zhang, Dongkai
    Kang, Gaoqiang
    Zhan, Dong
    Roberts, Clive
    IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2022, 23 (08) : 10104 - 10125
  • [38] Contact with Overhead Power Lines How Can We Prevent This?
    Crow, D. Ray
    2009 IEEE IAS ELECTRICAL SAFETY WORKSHOP, 2009, : 22 - 24
  • [39] Overhead contact lines - Structural design based on en 50119
    Wiesner, Wolfgang
    eb - Elektrische Bahnen, 2010, 108 (10): : 446 - 452
  • [40] Spring-type tensioning equipment for overhead contact lines
    Fischer, Bertram