Radial Imaging With Multipolar Magnetic Encoding Fields

被引:11
|
作者
Schultz, Gerrit [1 ]
Weber, Hans [1 ]
Gallichan, Daniel [1 ]
Witschey, Walter R. T. [1 ]
Welz, Anna M. [1 ]
Cocosco, Chris A. [1 ]
Hennig, Juergen [1 ]
Zaitsev, Maxim [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Radiol, D-79106 Freiburg, Germany
关键词
Image reconstruction; nonlinear encoding fields; parallel imaging; radial imaging; spatial encoding; FAST FOURIER-TRANSFORMS; RECONSTRUCTION; MRI; GRADIENTS;
D O I
10.1109/TMI.2011.2164262
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present reconstruction methods for radial magnetic resonance imaging (MRI) data which were spatially encoded using a pair of orthogonal multipolar magnetic fields for in-plane encoding and parallel imaging. It is shown that a direct method exists in addition to iterative reconstruction. Standard direct projection reconstruction algorithms can be combined with a previously developed direct reconstruction for multipolar encoding fields acquired with Cartesian trajectories. The algorithm is simplified by recasting the reconstruction problem into polar coordinates. In this formulation distortion and aliasing become separate effects. Distortion occurs only along the radial direction and aliasing along the azimuthal direction. Moreover, aliased points are equidistantly distributed in this representation, and, consequently, Cartesian SENSE is directly applicable with highly effective unfolding properties for radio-frequency coils arranged with a radial symmetry. The direct and iterative methods are applied to simulated data to analyze basic properties of the algorithms and for the first time also measured in vivo data are presented. The results are compared to linear spatial encoding using a radial trajectory and quadrupolar encoding using a Cartesian trajectory. The direct reconstruction gives good results for fully sampled datasets. Undersampled datasets, however, show star-shaped artifacts, which are significantly reduced with the iterative reconstruction.
引用
收藏
页码:2134 / 2145
页数:12
相关论文
共 50 条
  • [21] Radial heliospheric magnetic fields detected by Ulysses
    Jones, GH
    Balogh, A
    Forsyth, RJ
    GEOPHYSICAL RESEARCH LETTERS, 1998, 25 (16) : 3109 - 3112
  • [23] Cylindrical spacetimes due to radial magnetic fields
    Vesely, Jiri
    Zofka, Martin
    PHYSICAL REVIEW D, 2021, 103 (02)
  • [24] CALCULATION OF MULTIPOLAR PULSED MAGNETIC-FIELDS WITH SOME ESTIMATION OF THEIR DIFFUSION INTO CONDUCTORS
    RYKOV, VL
    ZHURNAL TEKHNICHESKOI FIZIKI, 1978, 48 (12): : 2464 - 2471
  • [25] Angular Dependence of Coherent Radio Emission from Magnetars with Multipolar Magnetic Fields
    Yamasaki, Shotaro
    Eksi, Kazim Yavuz
    Gogus, Ersin
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2022, 512 (03) : 3189 - 3194
  • [26] MICROWAVE PLASMA SOURCE FOR ION SOURCES WITH MULTIPOLAR AND AXIAL MAGNETIC-FIELDS
    NIHEI, H
    MORIKAWA, J
    INOUE, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1990, 29 (05): : L822 - L825
  • [27] FIELDS AND GRADIENTS IN MULTIPOLAR MAGNETS
    SOTGIU, A
    JOURNAL OF APPLIED PHYSICS, 1986, 59 (03) : 689 - 693
  • [28] A STUDY OF PLASMA PROPERTIES FOR VARIOUS MAGNETIC FIELDS IN A MICROWAVE MULTIPOLAR ECR PLASMA
    Zhang Yanling Ning Zhaoyuan Xiao Yujing Ren Zhaoxing Li Xiangqun Institute of Plasma Physics Academia Sinica Hefei P R China
    真空科学与技术, 1992, (Z1) : 151 - 154
  • [29] Imaging insights into magnetic fields
    不详
    MATERIALS WORLD, 2008, 16 (05) : 14 - 14
  • [30] Quantification of Thoracic Blood Flow Using Volumetric Magnetic Resonance Imaging With Radial Velocity Encoding In Vivo Validation
    Frydrychowicz, Alex
    Wieben, Oliver
    Niespodzany, Eric
    Reeder, Scott B.
    Johnson, Kevin M.
    Francois, Christopher J.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (12) : 819 - 825