Homogeneous time-resolved IL-2-IL-2Rα assay using fluorescence resonance energy transfer

被引:37
|
作者
Stenroos, K
Hurskainen, P
Eriksson, S
Hemmila, I
Blomberg, K
Lindqvist, C
机构
[1] Abo Akad Univ, Dept Biol, FIN-20520 Turku, Finland
[2] Wallac Oy, FIN-20101 Turku, Finland
关键词
FRET; hIL-2R alpha; baculovirus; fluorometry;
D O I
10.1006/cyto.1997.0321
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A homogeneous receptor-ligand assay based on fluorescence resonance energy transfer is described. Tn the assay, recombinant human interleukin 2 (IL-2) and a monoclonal antibody against the human IL-2 receptor a chain were labelled with a highly fluorescent europium chelate and Cy5, respectively, As a result of a successful receptor-ligand complex formation, these labels are brought into close proximity, which will thereby allow an energy transfer to occur from the donor (europium) to the acceptor (Cy5), upon excitation of the donor. Utilization of specific non-neutralizing antibodies made it possible to use crude hIL-2R alpha membranes prepared from recombinant baculovirus-infected Sf9 insect cells. The specific energy transfer was measured at the emission wavelength of Cy5 using a time-resolved fluorometer. The data presented, demonstrate that this assay design can be utilized for saturation as well as competitive binding experiments in addition to regular receptor titrations. As a rapid simple homogeneous assay it is particularily suitable for high throughput screening analyses. (C) 1998 Academic Press.
引用
收藏
页码:495 / 499
页数:5
相关论文
共 50 条
  • [41] Recommendations for the reduction of compound artifacts in time-resolved fluorescence resonance energy transfer assays
    Imbert, Pierre-Eloi
    Unterreiner, Vincent
    Siebert, Daniela
    Gubler, Hanspeter
    Parker, Christian
    Gabriel, Daniela
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2007, 5 (03) : 363 - 372
  • [42] Building homogeneous time-resolved fluorescence resonance energy transfer assays for characterization of bivalent inhibitors of an inhibitor of apoptosis protein target
    Chaudhry, Charu
    Davis, Jonathan
    Zhang, Yong
    Posy, Shana
    Lei, Ming
    Shen, Henry
    Yan, Chunhong
    Devaux, Brigitte
    Zhang, Litao
    Blat, Yuval
    Metzler, William
    Borzilleri, Robert M.
    Talbott, Randy L.
    ANALYTICAL BIOCHEMISTRY, 2016, 497 : 8 - 17
  • [43] Development of a coactivator displacement assay for the orphan receptor estrogen-related receptor-γ using time-resolved fluorescence resonance energy transfer
    Gowda, Krishne
    Marks, Bryan D.
    Zielinski, Thomas K.
    Ozers, Mary Szatkowski
    ANALYTICAL BIOCHEMISTRY, 2006, 357 (01) : 105 - 115
  • [44] Homogeneous time-resolved fluorescence quenching assay (LANCE) for caspase-3
    Karvinen, J
    Hurskainen, P
    Gopalakrishnan, S
    Burns, D
    Warrior, U
    Hemmilä, I
    JOURNAL OF BIOMOLECULAR SCREENING, 2002, 7 (03) : 223 - 231
  • [45] Homogeneous time-resolved fluorescence quenching assay (TruPoint) for nucleic acid detection
    Ylikoski, A
    Elomaa, A
    Ollikka, P
    Hakala, H
    Mukkala, VM
    Hovinen, J
    Hemmilä, I
    CLINICAL CHEMISTRY, 2004, 50 (10) : 1943 - 1947
  • [46] Development of a time-resolved fluorometric method for observing hybridization in living cells using fluorescence resonance energy transfer
    Tsuji, A
    Sato, Y
    Hirano, M
    Suga, T
    Koshimoto, H
    Taguchi, T
    Ohsuka, S
    BIOPHYSICAL JOURNAL, 2001, 81 (01) : 501 - 515
  • [47] A flow injection kinase assay system based on time-resolved fluorescence resonance energy-transfer detection in the millisecond range
    Hirata, J
    de Jong, CF
    van Dongen, MM
    Buijs, J
    Ariese, F
    Irth, H
    Gooijer, C
    ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4292 - 4298
  • [48] Binding characterization of the interleukin-13 signaling complex and development of a ternary time-resolved fluorescence resonance energy transfer assay
    Yang, Xiaoke
    Lee, Julie
    Brooks, Jonathan
    Wilhelm, James
    Myszka, David
    Kasaian, Marion T.
    Goldman, Samuel
    Wolf, Stanley
    Fitz, Lori J.
    ANALYTICAL BIOCHEMISTRY, 2008, 376 (02) : 206 - 212
  • [49] Rapid and simple quantitation of methamphetamine by using a homogeneous time-resolved fluoroimmunoassay based on fluorescence resonance energy transfer from europium to Cy5
    Kimura, H
    Matsumoto, K
    Mukaida, M
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (08) : 799 - 804
  • [50] Development of a time-resolved fluorescence resonance energy transfer assay (cell TR-FRET) for protein detection on intact cells
    Lundin, K
    Blomberg, K
    Nordström, T
    Lindqvist, C
    ANALYTICAL BIOCHEMISTRY, 2001, 299 (01) : 92 - 97