Influence of Prosthetic Design on Squeaking After Ceramic-on-Ceramic Total Hip Arthroplasty

被引:54
|
作者
Swanson, Todd V. [1 ,2 ]
Peterson, David J. [1 ,2 ]
Seethala, Raghavendran [3 ]
Bliss, Ryan L. [1 ,2 ]
Spellmon, Calvin A. [1 ,2 ]
机构
[1] Desert Orthopaed Ctr, Swanson Hip & Knee Ctr Excellence, Las Vegas, NV 89121 USA
[2] Desert Orthopaed Ctr, Res Inst, Las Vegas, NV 89121 USA
[3] King George Hosp Visakhapatnam, Dept Orthopaed, Visakhapatnam, Andhra Pradesh, India
来源
JOURNAL OF ARTHROPLASTY | 2010年 / 25卷 / 06期
关键词
hip arthroplasty; ceramic; squeak; noise; ACETABULAR CUP; WEAR; ANTEVERSION; FRACTURE;
D O I
10.1016/j.arth.2010.04.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Squeaky ceramic-on-ceramic (COC) total hips have received much recent publicity, and implant design may be implicated. We reviewed 270 consecutive COC total hip arthroplasties in 233 patients comparing 4 implant combinations representing 4 manufacturers. A cohort (n = 45) of Stryker Trident acetabular cups paired with Stryker Accolade femoral stems showed a dramatically higher incidence of "problem squeaking"-defined as always audible to others and occurring at least once per week-with a 35.6% incidence of squeaking and 11.1% incidence of problem squeaking. The 3 non-Stryker designs (n = 225) revealed 3.6% squeaking (P < .0001) and 0.44% problem squeaking (P = .006). The Stryker system has a unique design and metallurgy. Our results suggest that although the genesis of squeaking in COC total hips is multifactorial, prosthetic design plays a key role.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 50 条
  • [21] Ceramic-on-Ceramic Total Hip Arthroplasty: Update
    Capello, William N.
    D'Antonio, James A.
    Feinberg, Judy R.
    Manley, Michael T.
    Naughton, Marybetb
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 39 - 43
  • [22] Ceramic-on-ceramic implants in total hip arthroplasty
    Colwell, C
    D'Antonio, JA
    Capello, WN
    Hardwick, ME
    BIOCERAMICS 17, 2005, 284-286 : 1003 - 1006
  • [23] Ceramic-on-ceramic total hip arthroplasty: Is squeaking related to an inaccurate three-dimensional hip anatomy reconstruction?
    Sariali, E.
    Klouche, S.
    Mamoudy, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (04) : 437 - 440
  • [24] Arthrosynovial cyst of the hip after total hip arthroplasty with a ceramic-on-ceramic interface
    Legaye, J
    Lenfant, P
    Delos, M
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (05): : 475 - 478
  • [25] Fracture of a ceramic femoral head after ceramic-on-ceramic total hip arthroplasty
    Malillos Toran, Manuel
    Cuenca, Jorge
    Antonio Martinez, Angel
    Herrera, Antonio
    Vicente Thomas, Javier
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 1072 - 1073
  • [26] Pseudotumor from ceramic-on-ceramic total hip arthroplasty
    Ciatti, Corrado
    Maniscalco, Pietro
    Bosio, Silvia
    Pagliarello, Calogero Puma
    Bianchi, Giuseppe
    Quattrini, Fabrizio
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2024, 116
  • [27] Osteosarcoma Around a Ceramic-on-Ceramic Total Hip Arthroplasty
    Levett, Jordan J.
    Turcotte, Robert E.
    Jung, Sungmi
    Antoniou, John
    Huk, Olga L.
    ARTHROPLASTY TODAY, 2023, 19
  • [28] Ceramic-on-Ceramic Total Hip Arthroplasty: The USA Experience
    Garino, J. P.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 95 - 100
  • [29] Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty
    Young-Kyun Lee
    Jae-Young Lim
    Yong-Chan Ha
    Tae-Young Kim
    Woon-Hwa Jung
    Kyung-Hoi Koo
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1155 - 1162
  • [30] Modern ceramic-on-ceramic bearings in total hip arthroplasty
    Nau, Thomas
    Raschid, Josef
    Kirnbauer, Werner
    Schwischei, Harald
    Ehall, Reinhard
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 2005, 155 (3-4) : 70 - 74