Energy Conservation Approach for Continuous Power Quality Improvement: A Case Study

被引:19
|
作者
Nadimuthu, Lalith Pankaj Raj [1 ]
Victor, Kirubakaran [1 ]
Basha, Chakarajamula Hussaian [2 ]
Mariprasath, T. [2 ]
Dhanamjayulu, C. [3 ]
Padmanaban, Sanjeevikumar [4 ,5 ]
Khan, Baseem [6 ]
机构
[1] Gandhigram Rural Inst Deemed Univ, Ctr Rural Energy, Chinnalapatti 624302, Tamil Nadu, India
[2] KSRM Coll Engn Autonomous, Kadapa 516003, Andhra Pradesh, India
[3] VIT Univ, Sch Elect Engn, Vellore 632014, Tamil Nadu, India
[4] Aarhus Univ, CTIF Global Capsule, Dept Business Dev & Technol, DK-8000 Aarhus, Denmark
[5] Prince Sultan Univ, Renewable Energy Lab REL, Commun & Networking Dept, Riyadh 11586, Saudi Arabia
[6] Hawassa Univ, Dept Elect & Comp Engn, Awasa 1530, Ethiopia
关键词
Power harmonic filters; Textile industry; Harmonic analysis; Power quality; Induction motors; Energy conservation; Industries; Carbon emission reduction; energy audit; energy conservation; harmonic mitigation; passive mitigation techniques; and power quality;
D O I
10.1109/ACCESS.2021.3123153
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work focused on a harmonic mitigating filter and investigated the effect of the harmonic mitigating filter in the textile industry with innovative energy conservation strategies for energy bill reduction, which covers a pathway to climate change mitigation. Here, the effect of the harmonic filter is found out by the systematic energy audit methodology (Preliminary, Detailed and Post-Audit phase). From the energy auditing, it has been found that the textile industry needed a passive harmonic filter for harmonic mitigation. Since, third, fifth, and seventh order of harmonic predominantly exists in the system. The high stability at higher current, known tuning frequency, low cost and low power consumption makes the passive filter to be the best fit for the system. The voltage and current Total Harmonic Distortion Factor (THDF) have been measured using the class 'A' power quality and energy analyzer. The harmonic filter's effect in harmonics mitigation is prominent; 66.45% of the reduction of current harmonics which is achieved after installing the passive filter at the Point of Common Coupling (PCC) of the system. Also, the reduction of harmonics ensures energy conservation through the reduction of additional losses (joule, copper and eddy current losses). The techno-economic analysis with payback period calculation is carried out and reported. Also, the effect of harmonics like mechanical anomalies (temperature rise) is carefully studied using an infrared thermo graphic technique in the textile industry's motor loads. The energy conservation and their carbon emission reduction are calculated and reported.
引用
收藏
页码:146959 / 146969
页数:11
相关论文
共 50 条
  • [31] Analysis on the Implementation of Energy Management and Conservation Case Study: Pemaron Gas Power Plant
    Ramadhani, P.
    Hardiles
    Sinisuka, N. I.
    Dinata, I. S.
    Subawa, P.
    Mahendra
    Purwakanta
    Sukama, I. N.
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 225 - 229
  • [32] QUALITY IMPROVEMENT - A CASE-STUDY
    BORCHARDT, JK
    CHEMTECH, 1990, 20 (07) : 406 - 407
  • [33] Grading: An Annotated "Pen and Paper" Approach to Multidimensional Case-Mix-Adjusted Continuous Quality Improvement
    Stineman, Margaret G.
    Charles, Jeremy
    Kurichi, Jibby E.
    TOPICS IN STROKE REHABILITATION, 2010, 17 (04) : 262 - 270
  • [34] THE LINK BETWEEN CONTINUOUS QUALITY IMPROVEMENT AND CASE-MANAGEMENT
    CESTA, TG
    JOURNAL OF NURSING ADMINISTRATION, 1993, 23 (06): : 55 - 61
  • [35] Continuous Improvement in Continuous Quality Control
    Bennett, Sterling T.
    CLINICAL CHEMISTRY, 2016, 62 (10) : 1299 - 1301
  • [36] A continuous quality improvement pilot study: Impact on nutritional care quality
    Simmons, Sandra F.
    Schnelle, John F.
    JOURNAL OF THE AMERICAN MEDICAL DIRECTORS ASSOCIATION, 2006, 7 (08) : 480 - 485
  • [37] Quality management for continuous improvement: a case study using the A3 Method in document management
    da Silva, Matheus Cruz Sandes
    Ribeiro, Tiago Miranda
    Pires, Paulo Cesar Fonseca
    de Oliveira, Lucia Helena Saraiva
    Geronimo, Maycon da Silva
    REVISTA DE GESTAO E SECRETARIADO-GESEC, 2023, 14 (08): : 13061 - 13081
  • [38] Continuous Quality Improvement of Nursing Care: Case Study of a Clinical Pathway Revision for Cardiac Catheterization
    Yan, Yu-Hua
    Chen, Yi
    Kung, Chih-Ming
    Peng, Li-Jung
    JOURNAL OF NURSING RESEARCH, 2011, 19 (03) : 181 - 189
  • [39] A Practical Approach to Using Quality Indicators in Continuous Quality Improvement Processes in a Medical Laboratory
    David, Remona E.
    Dobreanu, Minodora
    CLINICAL LABORATORY, 2022, 68 (01) : 78 - 90
  • [40] AN INTEGRATED QUALITY SYSTEMS-APPROACH TO QUALITY AND PRODUCTIVITY IMPROVEMENT IN CONTINUOUS MANUFACTURING PROCESSES
    DOOLEY, KJ
    KAPOOR, SG
    DESSOUKY, MI
    DEVOR, RE
    JOURNAL OF ENGINEERING FOR INDUSTRY-TRANSACTIONS OF THE ASME, 1986, 108 (04): : 322 - 327