Cyclic loading tests of earthquake-resilient prefabricated cross joint with single flange cover plate

被引:23
|
作者
Jiang, Zi-qin [1 ]
Lan, Tao [2 ]
Dou, Chao [3 ]
Wu, Ying-xia [1 ]
Zhang, Hang [1 ]
机构
[1] Beijing Univ Technol, Minist Educ, Key Lab Urban Secur & Disaster Engn, Beijing 100124, Peoples R China
[2] CSIC Architecture Design & Res Inst Co Ltd, Beijing 100021, Peoples R China
[3] Beijing Jiaotong Univ, Sch Civil Engn, Beijing 100044, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Earthquake-resilient; Prefabricated steel structure; Single flange cover plate; Dog-bone weakened; Hysteresis performance; Repair test; SEISMIC PERFORMANCE; HYSTERETIC BEHAVIOR; MOMENT CONNECTIONS; BRIDGE PIERS; STEEL; BEAM; DESIGN; WEB;
D O I
10.1016/j.jcsr.2019.105752
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Earthquake-resilient functions have become a frontier hot direction in the field of seismic engineering. Based on the concept of damage control, a new type of earthquake-resilient prefabricated cross joint (ERPCJ) with single flange cover plate (FCP) has been proposed. The ERPCJ is composed of a circular tubular steel column with a cantilever beam, a common beam, and a connection device. The plastic hinge will be transferred to the connection device, when the cantilever beam has been strengthened and the FCPs have been reduced. This design only requires replacement of the connection device to achieve recovery after an earthquake. In this study, seven low frequency cyclic loading tests were carried out on six specimens. The failure mode, hysteresis curve, skeleton curve, and other seismic performance indices of the joint were obtained. The influences of the weakened form, thickness and material property of the FCPs, and the gap between the beams on the seismic performance of the joint were mainly investigated. The experiments showed that the ERPCJ with reasonable parameter settings possessed good bearing capacity and hysteresis characteristics. The repair program of replacing the connection device was feasible and the requirements of earthquake resilience could be met. The ERPCJ utilizes the plastic deformation of the FCPs to dissipate the seismic energy and improve its ductility and rotation ability. In addition, thickness and material property of the FCPs, and a gap between the beams significantly affect the seismic performance of the joint. Therefore, the values of these parameters should be designed reasonably. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 26 条
  • [21] Experimental study of earthquake-resilient high ductility prefabricated opening-web steel channel beam-column joint
    Jiang, Zi-Qin
    Niu, Zi-Yao
    Cheng, Kui-Kui
    Yan, Tian
    Zhang, Ai-Lin
    JOURNAL OF BUILDING ENGINEERING, 2022, 49
  • [22] Design theory of earthquake-resilient prefabricated column foot joint with lateral force-resisting energy-consuming device
    Jiang, Zi-Qin
    Yang, Xiao-Feng
    Zhang, Ai-Lin
    Hua, Xing-Shang
    Chen, Xin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 198
  • [23] Simplified restoring force model of earthquake-resilient prefabricated column foot joint with lateral force-resisting energy-consuming device
    Jiang, Zi-Qin
    Yang, Xiao-Feng
    Zhang, Ai-Lin
    Hua, Xing-Shang
    Liu, Xue-Chun
    STRUCTURES, 2023, 57
  • [24] Seismic behaviour of an earthquake-resilient prefabricated beam-column cross joint可恢复功能装配式梁柱中柱节点抗震性能研究
    Ai-lin Zhang
    Ying-xia Wu
    Zi-qin Jiang
    Xu-qiao Zhang
    Chao Dou
    Journal of Zhejiang University-SCIENCE A, 2017, 18 : 927 - 941
  • [25] Radial stresses and resilient deformations of geogrid-stabilized unpaved roads under cyclic plate loading tests
    Sun, Xiaohui
    Han, Jie
    Kwon, Jayhyun
    Parsons, Robert L.
    Wayne, Mark H.
    GEOTEXTILES AND GEOMEMBRANES, 2015, 43 (05) : 440 - 449
  • [26] Cyclic loading tests of self-centering prestressed prefabricated steel beam-column joint with weakened FCP
    Jiang, Zi-Qin
    Chen, Mei-Lin
    Yang, Zhong-Shuai
    Li, Xiang-Yuan
    Cai, Chao
    ENGINEERING STRUCTURES, 2022, 252