Optimizing effects on airway pressure and minute volume during closed endotracheal suctioning: a simulated lung model

被引:3
|
作者
Jung, Fang [1 ,2 ,3 ]
Chou, Shang-Shing P. [2 ]
Yang, Shih-Hsing [1 ]
Lin, Jau-Chen [1 ]
Jow, Guey-Mei [4 ]
机构
[1] Fu Jen Catholic Univ, Dept Resp Therapy, New Taipei, Taiwan
[2] Fu Jen Catholic Univ, Dept Chem, New Taipei, Taiwan
[3] Fu Jen Catholic Univ, Grad Inst Biomed & Pharmaceut Sci, New Taipei, Taiwan
[4] Fu Jen Catholic Univ, Sch Med, 510 Zhongzheng Rd, New Taipei 24205, Taiwan
关键词
Closed endotracheal suctioning; COVID-19; mechanical ventilation; peak inspiratory pressure; positive end-expiratory pressure; MECHANICALLY VENTILATED PATIENTS; CATHETER SIZE; SYSTEMS; DERECRUITMENT; PREVENTION; PNEUMONIA; TUBES;
D O I
10.1177/00375497211006188
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A closed suction system is used to remove endotracheal secretions without interrupting the patient's ventilation. Closed suctioning may reduce adverse effects associated with suctioning with, for example, decreased clinical signs of hypoxemia and limited environmental, personnel, and patient contamination. However, it is not clear whether ventilation is maintained during the procedure. We aimed to determine the effects of endotracheal tube (ETT) size, suction catheter (SC) size, and SC length in the ETT on ventilation parameters measured during suction. Suction was performed on a test lung, ventilated with either volume-controlled continuous mandatory ventilation (VC-CMV) or pressure-controlled continuous mandatory ventilation (PC-CMV) using ETT sizes of 6.0-8.5 mm paired with SC sizes of 8-16 French gauge (Fr = 0.33 mm). Airway resistance (R-aw), peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), and expiratory minute volume (Vexp) were recorded for each ventilation episode by a HAMILTON-G5 ventilator. Here, R-aw was considerably increased by insertion of the SC into the ETT. This R-aw effect altered the PIP and Vexp. PIP was increased in VC-CMV because the ventilation area of the ETT was reduced, and Vexp was decreased in PC-CMV in relation to the size of the SC. PEEP decreased with application of the 16 Fr SC and 30 L/min flow rate in VC-CMV. We conclude that airway pressure and minute volume are not maintained during closed endotracheal suctioning with VC-CMV and PC-CMV, respectively. The degree of interference to ventilation is affected through selection of appropriate SC size and ventilation settings.
引用
收藏
页码:439 / 449
页数:11
相关论文
共 50 条
  • [41] VENTILATOR PERFORMANCE CHARACTERISTICS DURING AIRWAY PRESSURE RELEASE VENTILATION: A LUNG MODEL STUDY
    Yoshida, T.
    Uchiyama, A.
    Mashimo, T.
    Fujino, Y.
    INTENSIVE CARE MEDICINE, 2010, 36 : S109 - S109
  • [42] Accuracy of Reported Tidal Volume During Neonatal Ventilation With Airway Leak: A Lung Model Study
    Moon, Kazue
    Takeuchi, Muneyuki
    Tachibana, Kazuya
    Mizuguchi, Soichi
    Hirano, Shinya
    PEDIATRIC CRITICAL CARE MEDICINE, 2019, 20 (01) : E37 - E45
  • [43] Effects of lung volume on airway resistance during induced constriction in papain-treated rabbits
    Nagase, T
    Matsui, H
    Sudo, E
    Matsuse, T
    Ludwig, MS
    Fukuchi, Y
    JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (06) : 1872 - 1879
  • [44] Heart-lung interactions during positive pressure ventilation:: left ventricular pressure-volume momentary response to airway pressure elevation
    Haney, MF
    Johansson, G
    Häggmark, S
    Biber, B
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (06) : 702 - 709
  • [45] End-expiratory lung volume decreases during REM sleep despite continuous positive airway pressure
    Patrick Koo
    Eric J. Gartman
    Jigme M. Sethi
    F. Dennis McCool
    Sleep and Breathing, 2020, 24 : 119 - 125
  • [46] End-expiratory lung volume decreases during REM sleep despite continuous positive airway pressure
    Koo, Patrick
    Gartman, Eric J.
    Sethi, Jigme M.
    McCool, F. Dennis
    SLEEP AND BREATHING, 2020, 24 (01) : 119 - 125
  • [47] AIRWAY PRESSURE RELEASE VENTILATION MAINTAINS ALVEOLAR STABILITY BY LIMITING LOSS OF LUNG VOLUME DURING RELEASE PHASE
    Habashi, N.
    Roy, S. K.
    Nieman, G. F.
    Andrews, P.
    Statlin, J.
    Gatto, L.
    SHOCK, 2012, 37 : 102 - 103
  • [48] Effect of mean airway pressure on lung volume during high-frequency oscillatory ventilation of preterm infants
    Thome, U
    Töpfer, A
    Schaller, P
    Pohlandt, F
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (04) : 1213 - 1218
  • [49] Effects of exogenous surfactant on lung pressure-volume characteristics during liquid ventilation
    TarczyHornoch, P
    Hildebrandt, J
    Mates, EA
    Standaert, TA
    Lamm, WJE
    Hodson, WA
    Jackson, JC
    JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (05) : 1764 - 1771
  • [50] RAPID MECHANICAL VENTILATION EFFECTS ON TRACHEAL AIRWAY PRESSURE, LUNG-VOLUME, AND BLOOD-GASES OF RABBITS
    GONZALEZ, F
    RICHARDSON, P
    CARLSTROM, JR
    BOSE, CL
    AMERICAN JOURNAL OF PERINATOLOGY, 1986, 3 (04) : 347 - 351