A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging

被引:11
|
作者
Deng, Luzhen [1 ,2 ]
Wei, Biao [1 ]
He, Peng [1 ,3 ]
Zhang, Yi [4 ]
Feng, Peng [1 ,3 ]
机构
[1] Chongqing Univ, Key Lab Optoelect Technol & Syst, Minist Educ, Room 1311,Main Bldg,Shapingba St, Chongqing 400044, Peoples R China
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Chongqing Univ, Engn Res Ctr Ind Computed Tomog Nondestruct Testi, Minist Educ, Chongqing 400044, Peoples R China
[4] Sichuan Univ, Coll Comp Sci, Chengdu 610065, Sichuan, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Geant4; Monte Carlo simulation; multi-pinhole; X-ray fluorescence computed tomography; gold nanoparticles; bioimaging modality; NANOPARTICLE-LOADED OBJECTS; EMISSION;
D O I
10.2147/IJN.S179875
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Background: X-ray fluorescence (XRF) computed tomography (XFCT) has shown promise for molecular imaging of metal nanoparticles such as gold nanoparticles (GNPs) and benchtop XFCT is under active development due to its easy access, low-cost instrumentation and operation. Purpose: To validate the performance of a Geant4-based Monte Carlo (MC) model of a benchtop multi-pinhole XFCT system for quantitative imaging of GNPs. Methods: The MC mode consisted of a fan-beam x-ray source (125 kVp), which was used to stimulate the emission of XRF from the GNPs, a phantom (3 cm in diameter) which included six or nine inserts (3 mm in diameter), each of which contained the same (1 wt. %) or various (0.08-1 wt. %) concentrations of GNPs, a multi-pinhole collimator which could acquire multiple projections simultaneously and a one-sided or two-sided two-dimensional (2D) detector. Various pinhole diameters (3.7, 2, 1, 0.5 and 0.25 mm) and various particle numbers (20, 40, 80 and 100 billion) were simulated and the results for single pinhole and multi-pinhole (9 pinholes) imaging were compared. Results: The image resolution for a 1 mm multi-pinhole was between 0.88 and 1.38 mm. The detection limit for multi-pinhole operation was about 0.09 wt. %, while that for the single pinhole was about 0.13 wt. %. For a fixed number of pinholes, noise increased with decreasing number of photons. Conclusion: The MC mode could acquire 2D slice images of the object without rotation and demonstrated that a multi-pinhole XFCT imaging system could be a potential bioimaging modality for nanomedical applications.
引用
收藏
页码:7207 / 7216
页数:10
相关论文
共 50 条
  • [11] G4XRTube: A Geant4-based Monte Carlo application for X-ray tube simulation
    Idrissi, Abdelghani
    Dourki, Ibrahym
    El Bardouni, T.
    El Hajjaji, O.
    El-Bouzaidi, Mohamed Drissi
    Mira, Mohamed
    RADIATION PHYSICS AND CHEMISTRY, 2023, 207
  • [12] Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: A Monte Carlo study
    Manohar, Nivedh
    Jones, Bernard L.
    Cho, Sang Hyun
    MEDICAL PHYSICS, 2014, 41 (10)
  • [13] Geant4-based Monte Carlo Simulator for Fan-and Cone-beam X-ray CT
    Zou, Jing
    Hu, Zhanli
    Gui, Jianbao
    Rong, Junyan
    Li, Yanming
    Zheng, Hairong
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [14] Simulation and Analysis of Imaging Process of Phosphor Screens for X-Ray Imaging of Streak Tube Using Geant4-Based Monte Carlo Method
    Wang, Zichen
    Lin, Riyi
    Liao, Yuxiang
    Tang, Lin
    Wu, Zhenhua
    Liu, Diwei
    Zhong, Renbin
    Zhang, Kaichun
    SENSORS, 2025, 25 (03)
  • [15] A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method
    Ahmed, Md Foiez
    Yasar, Selcuk
    Cho, Sang Hyun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (11) : 2483 - 2492
  • [16] Computed tomography x-ray characterization: A Monte Carlo study
    Campos, Luciana Tourinho
    de Jesus, Fillipe Machado
    de Souza Goncalves, Elicardo Alves
    Goncalves Magalhaes, Luis Alexandre
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167 (167)
  • [17] An Image-Based Mouse Model for Geant4 Monte Carlo Simulations of Multimodal Imaging with Benchtop X-Ray Fluorescence CT (XFCT) and Micro-CT
    Jayarathna, S.
    Ahmed, M. F.
    Cho, S. H.
    MEDICAL PHYSICS, 2018, 45 (06) : E369 - E369
  • [18] Linearly polarized X-ray fluorescence computed tomography based on a Thomson scattering light source: a Monte Carlo study
    Chi, Zhijun
    Du, Yingchao
    Huang, Wenhui
    Tang, Chuanxiang
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 (27) : 737 - 745
  • [19] Optimization of Detection Angle for Pinhole X-Ray Fluorescence Computed Tomography
    Guo Jing
    Feng Peng
    Deng Luzhen
    Luo Yan
    He Peng
    Wei Biao
    ACTA OPTICA SINICA, 2020, 40 (01)
  • [20] Pinhole X-ray fluorescence imaging of gadolinium and gold nanoparticles using polychromatic X-rays: a Monte Carlo study
    Jung, Seongmoon
    Sung, Wonmo
    Ye, Sung-Joon
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 5805 - 5817