Efficacy of ultrasound-guided fine-needle aspiration biopsy in the diagnosis of complex thyroid nodules

被引:82
|
作者
Braga, M
Cavalcanti, TC
Collaço, LM
Graf, H
机构
[1] Univ Fed Parana, Hosp Clin, Serv Anat Patol, BR-80060240 Curitiba, Parana, Brazil
[2] Univ Fed Parana, Hosp Clin, Serv Endocrinol & Metab Parana, BR-80060240 Curitiba, Parana, Brazil
来源
关键词
D O I
10.1210/jc.86.9.4089
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cystic thyroid nodules are considered to be one of the major causes of nondiagnostic and false-negative results on conventional fine-needle aspiration biopsy, thus limiting the potential of this method for the evaluation of complex (solid-cystic) thyroid nodules. Although ultrasound-guided fine-needle aspiration biopsy has emerged as a highly effective diagnostic method for the assessment of nonpalpable and difficult to palpate nodules, its role in complex nodules has not yet been carefully evaluated. In this study, we report the efficacy of ultrasound-guided fine-needle aspiration biopsy in 124 complex nodules in 113 patients. This method proved to be highly effective, yielding a satisfactory specimen for cytological evaluation in 94% of the nodules, suggesting that it is an excellent modality for the evaluation of complex nodules and also for the reevaluation of those nodules with a nondiagnostic result on conventional fine-needle aspiration biopsy.
引用
收藏
页码:4089 / 4091
页数:3
相关论文
共 50 条
  • [11] THYROID-NODULES - CLINICAL EFFECT OF ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION BIOPSY
    TAKASHIMA, S
    FUKUDA, H
    KOBAYASHI, T
    JOURNAL OF CLINICAL ULTRASOUND, 1994, 22 (09) : 535 - 542
  • [12] Ultrasound-guided versus standard fine-needle aspiration biopsy in the evaluation of thyroid nodules
    Lombardi, CP
    Raffaelli, M
    de Crea, C
    Traini, E
    Rossi, ED
    Fadda, G
    Bellantone, R
    BRITISH JOURNAL OF SURGERY, 2004, 91 (03) : 379 - 379
  • [13] Role of ultrasound-guided fine-needle aspiration biopsy in evaluation of nonpalpable thyroid nodules
    Hagag, P
    Strauss, S
    Weiss, M
    THYROID, 1998, 8 (11) : 989 - 995
  • [14] Ultrasound-guided fine-needle aspiration biopsy of thyroid nodules in patients on oral anticoagulants
    Grandone, E.
    Barcellona, D.
    Colaizzo, D.
    Marongiu, F.
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2017, 40 (07): : 785 - 786
  • [15] Usefulness of ultrasound-guided fine-needle aspiration biopsy of thyroid nodules ≤1.5 cm
    Shafi, Nadiya
    Farghaly, Hanan
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 128 (04) : 701 - 702
  • [16] Ultrasound-guided fine-needle aspiration biopsy of the thyroid bed
    Krisnamurthy, S
    Bedi, DG
    Caraway, NP
    CANCER CYTOPATHOLOGY, 2001, 93 (03): : 199 - 205
  • [17] Ultrasound-guided fine-needle aspiration biopsy of thyroid masses
    Carmeci, C
    Jeffrey, RB
    McDougall, IR
    Nowels, KW
    Weigel, RJ
    THYROID, 1998, 8 (04) : 283 - 289
  • [18] Evaluation of ultrasound guided fine-needle aspiration biopsy for thyroid nodules
    Hatada, T
    Okada, K
    Ishii, H
    Ichii, S
    Utsunomiya, J
    AMERICAN JOURNAL OF SURGERY, 1998, 175 (02): : 133 - 136
  • [19] COMPARISON OF THE EFFICACY AND SAFETY OF ULTRASOUND-GUIDED CORE NEEDLE BIOPSY VERSUS FINE-NEEDLE ASPIRATION FOR EVALUATING THYROID NODULES
    Chen, Bihong T.
    Jain, Akshay B.
    Dagis, Andrew
    Chu, Peiguo
    Vora, Lalit
    Maghami, Ellie
    Salehian, Behrouz
    ENDOCRINE PRACTICE, 2015, 21 (02) : 128 - 135
  • [20] ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION BIOPSY OF SOLITARY PULMONARY NODULES
    CHEN, CC
    HSU, WH
    HUANG, CM
    CHEN, CY
    KWAN, PC
    CHIANG, CD
    JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (09) : 531 - 536