Estimates of percentage body fat in young adolescents: a comparison of dual-energy X-ray absorptiometry and air displacement plethysmography

被引:27
|
作者
Radley, D
Gately, PJ
Cooke, CB
Carroll, S
Oldroyd, B
Truscott, JG
机构
[1] Leeds Metropolitan Univ, Sch Leisure & Sport, Leeds LS6 3QS, W Yorkshire, England
[2] Univ Leeds, Ctr Bone & Body Composit Res, Leeds LS2 9JT, W Yorkshire, England
[3] Univ Leeds, Sch Healthcare Studies, Imaging Sci Grp, Leeds LS2 9JT, W Yorkshire, England
关键词
air displacement plethysmography; dual-energy X-ray absorptiometry; body composition; children;
D O I
10.1038/sj.ejcn.1601702
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: To evaluate the accuracy of percentage body fat (% fat) estimates from air displacement plethysmography ( ADP) against an increasingly recognised criterion method, dual-energy X-ray absorptiometry (DXA), in young adolescents. Design: Cross-sectional evaluation. Setting: Leeds General Infirmary, Centre for Bone and Body Composition Research, Leeds, UK. Subjects: In all, 28 adolescents (12 males and 16 females), age (mean+/-s.d.) 14.9+/-0.5 y, body mass index 21.2+/-2.9 kg/m(2) and body fat (DXA) 24.2+/-10.2% were assessed. Results: ADP estimates of % fat were highly correlated with those of DXA in both male and female subjects (r = 0.84 - 0.95, all P<0.001; s.e.e. = 3.42 - 3.89%). Mean % fat estimated by ADP using the Siri (1961) equation (ADP(Siri)) produced a nonsignificant overestimation in males (0.67%), and a nonsignificant underestimation in females (1.26%). Mean % fat estimated by ADP using the Lohman (1986) equations (ADP(Loh)) produced a nonsignificant underestimation in males (0.90%) and a significant underestimation in females (3.29%; P<0.01). Agreement between ADP and DXA methods was examined using the total error (TE) and methods of Bland and Altman (1986). Males produced a smaller TE (ADP(Siri) 3.28%; ADP(Loh) 3.49%) than females (ADP(Siri) 3.81%; ADP(Loh) 4.98%). The 95% limits of agreement were relatively similar for all % fat estimates, ranging from +/-6.57 to +/-7.58%. Residual plot analyses, of the individual differences between ADP and DXA, revealed a significant bias associated with increased % fat ( DXA), only in girls (P<0.01). Conclusions: We conclude that ADP, at present, has unacceptably high limits of agreement compared to a criterion DXA measure. The ease of use, suitability for various populations and cost of ADP warrant further investigation of this method to establish biological variables that may influence the validity of body fat estimates.
引用
收藏
页码:1402 / 1410
页数:9
相关论文
共 50 条
  • [1] Estimates of percentage body fat in young adolescents: a comparison of dual-energy X-ray absorptiometry and air displacement plethysmography
    D Radley
    P J Gately
    C B Cooke
    S Carroll
    B Oldroyd
    J G Truscott
    European Journal of Clinical Nutrition, 2003, 57 : 1402 - 1410
  • [2] A Comparison Of Body Fat Percentage Estimates Between Dual-energy X-ray Absorptiometry And Air Displacement Plethysmography
    Nowak, Kathryn M.
    Kaminsky, Leonard A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S299 - S300
  • [3] Validity and reliability of bioelectrical impedance analysis to estimate body fat percentage against air displacement plethysmography and dual-energy X-ray absorptiometry
    von Hurst, Pamela R.
    Walsh, Daniel C. I.
    Conlon, Cathryn A.
    Ingram, Michelle
    Kruger, Rozanne
    Stonehouse, Welma
    NUTRITION & DIETETICS, 2016, 73 (02) : 197 - 204
  • [4] Body Composition at 6 months of Life: Comparison Of Air Displacement Plethysmography and Dual-Energy X-Ray Absorptiometry
    Fields, David A.
    Demerath, Ellen W.
    Pietrobelli, Angelo
    Chandler-Laney, Paula C.
    OBESITY, 2012, 20 (11) : 2302 - 2306
  • [5] A comparison of body composition estimates using dual-energy X-ray absorptiometry and air-displacement plethysmography in South African neonates
    Wrottesley, S. V.
    Pisa, P. T.
    Micklesfield, L. K.
    Pettifor, J. M.
    Norris, S. A.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2016, 70 (11) : 1254 - 1258
  • [6] A comparison of body composition estimates using dual-energy X-ray absorptiometry and air-displacement plethysmography in South African neonates
    S V Wrottesley
    P T Pisa
    L K Micklesfield
    J M Pettifor
    S A Norris
    European Journal of Clinical Nutrition, 2016, 70 : 1254 - 1258
  • [7] Body composition by air displacement plethysmography in middle-aged and elderly Japanese - Comparison with dual-energy X-ray absorptiometry
    Koda, M
    Tsuzuku, S
    Ando, F
    Niino, N
    Shimokata, H
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 484 - 488
  • [8] VALIDITY AND RELIABILITY OF BIOELECTRICAL IMPEDANCE ANALYSIS TO ESTIMATE BODY FAT COMPARED TO AIR DISPLACEMENT PLETHYSMOGRAPHY AND DUAL-ENERGY X-RAY ABSORPTIOMETRY
    Conlon, C.
    Ingram, M.
    Walsh, D.
    von Hurst, P.
    Kruger, R.
    Stonehouse, W.
    ANNALS OF NUTRITION AND METABOLISM, 2013, 63 : 1478 - 1478
  • [9] Percentage Body Fat by Dual-Energy X-Ray Absorptiometry Is Associated With Menstrual Recovery in Adolescents With Anorexia Nervosa
    Pitts, Sarah
    Blood, Emily
    Divasta, Amy
    Gordon, Catherine M.
    JOURNAL OF ADOLESCENT HEALTH, 2014, 54 (06) : 739 - 741
  • [10] PERCENTAGE BODY FAT BY DUAL-ENERGY X-RAY ABSORPTIOMETRY IS ASSOCIATED WITH MENSTRUAL RECOVERY IN ADOLESCENTS WITH ANOREXIA NERVOSA
    Pitts, Sarah
    Blood, Emily
    Divasta, Amy
    Gordon, Catherine
    JOURNAL OF ADOLESCENT HEALTH, 2014, 54 (02) : S74 - S75