REDSoX: Monte-Carlo ray-tracing for a soft X-ray spectroscopy polarimeter

被引:3
|
作者
Gunther, Hans M. [1 ]
Egan, Mark [1 ]
Heilmann, Ralf K. [1 ]
Heine, Sarah N. T. [1 ]
Hellickson, Tim [1 ]
Frost, Jason [1 ,2 ]
Marshell, Herman L. [1 ]
Schulz, Nobert S. [1 ]
Theriault-Shay, Adam [1 ]
机构
[1] MIT, Kavli Inst Astrophys & Space Res, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] Stanford Univ, Dept Phys, Stanford, CA 94305 USA
基金
美国国家航空航天局;
关键词
ray-tracing; X-ray optics; critical angle transmission grating; REDSoX polarimeter; multi-layer mirror; polarimetry; TRANSMISSION;
D O I
10.1117/12.2273772
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
X-ray polarimetry offers a new window into the high-energy universe, yet there has been no instrument so far that could measure the polarization of soft X-rays (about 17-80 A) from astrophysical sources. The Rocket Experiment Demonstration of a Soft X-ray Polarimeter (REDSoX Polarimeter) is a proposed sounding rocket experiment that uses a focusing optic and splits the beam into three channels. Each channel has a set of critical angle transmission (CAT) gratings that disperse the x-rays onto a laterally graded multilayer (LGML) mirror, which preferentially reflects photons with a specific polarization angle. The three channels are oriented at 120 deg to each other and thus measure the three Stokes parameters: I, Q, and U. The period of the LGML changes with position. The main design challenge is to arrange the gratings so that they disperse the spectrum in such a way that all rays are dispersed onto the position on the multi-layer mirror where they satisfy the local Bragg condition despite arriving on the mirror at different angles due to the converging beam from the focusing optics. We present a polarimeteric Monte-Carlo ray-trace of this design to assess non-ideal effects from e.g. mirror scattering or the finite size of the grating facets. With mirror properties both simulated and measured in the lab for LGML mirrors of 80-200 layers we show that the reflectivity and the width of the Bragg-peak are sufficient to make this design work when non-ideal effects are included in the simulation. Our simulations give us an effective area curve, the modulation factor and the figure of merit for the REDSoX polarimeter. As an example, we simulate an observation of Mk 421 and show that we could easily detect a 20% linear polarization.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] MONTE-CARLO RAY TRACING FOR AXISYMMETRICAL OPTICAL ELEMENTS
    Andreev, E. S.
    Moiseev, M. A.
    Borisova, K. V.
    Doskolovich, L. L.
    COMPUTER OPTICS, 2015, 39 (03) : 357 - 362
  • [22] High performance ultrasound simulation using Monte-Carlo simulation: a GPU ray-tracing implementation
    Perez Cambet, Tomas
    Vitale, Santiago
    Larrabide, Ignacio
    16TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION PROCESSING AND ANALYSIS, 2020, 11583
  • [23] X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Vincze, L.
    Rackwitz, V.
    Reuter, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (24): : 3568 - 3575
  • [24] MONTE-CARLO MODELING OF X-RAY TRANSPORT IN A HETEROGENEOUS PHANTOM
    GOANS, RE
    BEMIS, CE
    WARNER, GG
    HEALTH PHYSICS, 1976, 31 (06): : 559 - 560
  • [25] MONTE-CARLO ERROR ANALYSIS IN X-RAY SPECTRAL DECONVOLUTION
    SHIRK, DG
    HOFFMAN, NM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05): : 809 - 811
  • [26] Monte-Carlo simulation of a micro focal X-ray tube
    Tavora, LMN
    Morton, EJ
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 783 - 787
  • [27] CALCULATION OF X-RAY GRID CHARACTERISTICS BY MONTE-CARLO METHODS
    KALENDER, WA
    PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (03): : 353 - 361
  • [28] Ray-tracing simulations of the soft X-ray scattered emission in obscured active galactic nuclei
    Mckaig, Jeffrey
    Ricci, Claudio
    Paltani, Stephane
    Gupta, K. K.
    Abel, Nicholas P.
    Ueda, Y.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2023, 526 (04) : 5072 - 5083
  • [29] McXtrace: a modern ray-tracing package for x-ray instrumentation
    Knudsen, Erik B.
    Prodi, Andrea
    Willendrup, Peter
    Lefmann, Kim
    Baltser, Jana
    Gundlach, Carsten
    del Rio, Manuel Sanchez
    Ferrero, Claudio
    Feidenhans'l, Robert
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS II, 2011, 8141
  • [30] Expected performance of a hard X-ray polarimeter (POLAR) by Monte Carlo simulation
    Xiong, Shaolin
    Produit, Nicolas
    Wu, Bobing
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 606 (03): : 552 - 559