Three-dimensional ultrasound-guided embryo transfer: A preliminary study

被引:16
|
作者
Letterie, GS [1 ]
机构
[1] Virginia Mason Med Ctr, Ctr Fertil & Reprod Endocrinol, Seattle, WA 98101 USA
关键词
three-dimensional ultrasound; embryo transfer; in vitro fertilization;
D O I
10.1016/j.ajog.2005.02.044
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Embryo transfer techniques have emerged Lis 1 of the most important variables during in vitro fertilization. Two-dimensional ultrasound guidance is an integral part of this procedure and a method to monitor catheter passage through the cervix into the endometrial cavity. Catheter placement may better be achieved with 3-dimensional monitoring to assess the relationship of the catheter tip to the uterine cavity. The purpose of this study was to compare the precision of catheter placement and position by 2- and 3-dimensional ultrasound. Study design: Twenty-four patients were studied. The cervix, Uterus, and endometrial cavity were prescreened in 2 dimensions at the midline in the longitudinal plane of the uterus. Embryo transfers were then performed Under 2-dimensional guidance. After satisfactory catheter placement and transfer of the embryos, the catheter was held in place for 60 to 120 seconds. During this interval, an automated, single sweep of the uterus and endometrial cavity was performed for net volume acquisition. All images were stored and retrospectively reviewed. Embryo transfer catheter placement with 2-dimensional Ultrasound guidance was then compared with the images obtained in 3 Simultaneous planes. Results: Visualization of the embryo catheter tip with 2-dimensional Ultrasound was achieved in all patients. These images suggested that the catheter was 2 cm from the uterine fundus and in the midline. Satisfactory 3-dimensional images for review and comparison were obtained in 21 of 24 patients. Three-dimensional ultrasound images confirmed placement and agreed with findings 9 of 2-dimensional ultrasound images in 17 of 21 patients. In 4 patients, the catheter tip on 3-dimensional Ultrasound was observed to be displaced either anteriorly or laterally from the ideal region as suggested by 2-dimensional ultrasound. In 1 case, the catheter tip on 3-dimensional Ultrasound was observed to be far laterally in the region of the uterine cornua. Conclusion: Two-dimensional ultrasound-guided embryo transfer Continues to be the standard for image-guided transfers. Data of the present Study Suggest that the precision of catheter tip placement and consequently embryo transfer may be improved with 3-dimensional imaging. Four of 21 patients Studied had catheter tip placement in a different and less-than-ideal area when Studied with 3-dimensional ultrasound. Three-dimensional imaging may provide an improvement in embryo transfer technique and have a positive impact oil overall pregnancy rates. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1983 / 1987
页数:5
相关论文
共 50 条
  • [31] Ultrasound-guided embryo transfer: Does it improve IVF success?
    Shamonki, MI
    Spandorfer, SD
    Roberts, JE
    Rosenwaks, Z
    FERTILITY AND STERILITY, 2003, 80 : S127 - S128
  • [32] ULTRASOUND-GUIDED EMBRYO TRANSFER - AN UPDATED META-ANALYSIS
    Sallam, H. N.
    Sallam, N. H.
    Sallam, A. N.
    Ezzeldin, F.
    FERTILITY AND STERILITY, 2012, 98 (03) : S180 - S180
  • [33] Measurement of endometrial volume increase during the first week after embryo transfer by three-dimensional ultrasound to detect pregnancy: a preliminary study
    Martins, Wellington de Paula
    Ferriani, Rui Alberto
    Nastri, Carolina Oliveira
    dos Reis, Rosana Maria
    Mauad Filho, Francisco
    FERTILITY AND STERILITY, 2008, 90 (03) : 883 - 885
  • [34] Ultrasound-Guided Biopsy of Focal Lesions Using Three-Dimensional Ultrasound With a Matrix Array Transducer Comparison With 2-Dimensional Ultrasound in a Phantom Study
    Kim, Hyun Cheol
    Yang, Dal Mo
    Nam, Deok Ho
    Kim, Kun Woo
    INVESTIGATIVE RADIOLOGY, 2011, 46 (04) : 264 - 270
  • [35] Modified technique allowing interactive ultrasound-guided three-dimensional transperineal prostate implantation
    Stock, R.G.
    Stone, N.N.
    Wesson, M.F.
    DeWyngaert, J.K.
    International Journal of Radiation Oncology, Biology, Physics, 1995, 32 (01):
  • [36] Use of a Novel Three-Dimensional Model to Teach Ultrasound-guided Subclavian Vein Cannulation
    Tanwani, Jaya
    Nabecker, Sabine
    Hiansen, Joshua Qua
    Mashari, Azad
    Siddiqui, Naveed
    Arzola, Cristian
    Goffi, Alberto
    Peacock, Sharon
    ATS SCHOLAR, 2023, 4 (03): : 344 - 353
  • [37] Three-dimensional therapy needle applicator segmentation for ultrasound-guided focal liver ablation
    Gillies, Derek J.
    Awad, Joseph
    Rodgers, Jessica R.
    Edirisinghe, Chandima
    Cool, Derek W.
    Kakani, Nirmal
    Fenster, Aaron
    MEDICAL PHYSICS, 2019, 46 (06) : 2646 - 2658
  • [38] Real-Time Three-Dimensional Ultrasound-Guided Central Venous Catheter Placement
    Dowling, Myles
    Jlala, Hatem A.
    Hardman, Jonathan G.
    Bedforth, Nigel M.
    ANESTHESIA AND ANALGESIA, 2011, 112 (02): : 378 - 381
  • [39] Efficacy of a modified transvaginal ultrasound-guided fresh embryo transfer procedure
    Nakano, Raul
    Radaelli, Moacir R. M.
    Fujihara, Litsuko Shimabukuro
    Yoshinaga, Flavio
    Nakano, Enzo
    Almodin, Carlos Gilberto
    JORNAL BRASILEIRO DE REPRODUCAO ASSISTIDA, 2022, 26 (01): : 78 - 83
  • [40] Potentially important variables identified by transvaginal ultrasound-guided embryo transfer
    Woolcott, R
    Stanger, J
    HUMAN REPRODUCTION, 1997, 12 (05) : 963 - 966