Three-dimensional fast fluid attenuated inversion recovery (3D fast FLAIR): a new MRI sequence which increases the detectable cerebral lesion load in multiple sclerosis

被引:41
|
作者
Tubridy, N
Barker, GJ
Macmanus, DG
Moseley, IF
Miller, DH
机构
[1] Inst Neurol, NMR Res Unit, London WC1N 3BG, England
[2] UCL Natl Hosp Neurol & Neurosurg, London WC1N 3BG, England
来源
BRITISH JOURNAL OF RADIOLOGY | 1998年 / 71卷 / 848期
关键词
D O I
10.1259/bjr.71.848.9828796
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two-dimensional(2D) fluid attenuated inversion recovery (FLAIR) magnetic resonance imaging is superior to T(2) weighted conventional spin echo (CSE), in certain areas of the brain but not in others, in detecting the lesions of multiple sclerosis (MS). The present study evaluates the ability of a recently developed three-dimensional fast FLAIR (3D fast FLAIR) sequence in detecting and quantifying the brain lesions of multiple sclerosis. The lesion volumes measured on the 3D fast FLAIR sequence with 1.5 mm thick slices were compared with those obtained from CSE brain images with 5 mm thick slices. The findings seen in 3D fast FLAIR brain images in 10 normal control subjects are also described. 3D fast FLAIR images showed an overall increase of 34% in lesion volume compared with CSE. The increase was most marked in the periventricular and ''discrete" areas of the cerebral hemispheres. Lesion volumes seen in the subcortical areas were similar in both sequences. The CSE images displayed higher lesion volumes in the posterior cranial fossa. It is concluded that 3D fast FLAIR is a promising technique for quantifying cerebral pathology in MS which is not accessible to 2D CSE.
引用
收藏
页码:840 / 845
页数:6
相关论文
共 41 条
  • [21] Multiple sclerosis lesion detection with 3D double inversion recovery (DIR) as compared to 3D fluid low attenuation inversion recovery (T2-FLAIR): A systematic review and meta-analysis
    Mostardeiro, Thomaz R.
    Schmitt, Luiza Giuliani
    de Campos, Fillipe Thiago Xavier
    Xi, Yin
    Torri, Giovanni Brondani
    Carvalho, Bruno Murad
    Feltrin, Fabricio Stewan
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2025, 93
  • [22] Fast fluid-attenuated inversion-recovery imaging: first experience with a 3D version in epilepsy
    U. C. Wieshmann
    G. J. Barker
    M. R. Symms
    P. A. Bartlett
    J. M. Stevens
    S. D. Shorvon
    Neuroradiology, 1998, 40 : 483 - 489
  • [23] Three-dimensional fluid attenuated inversion recovery imaging with isotropic resolution and nonselective adiabatic inversion provides improved three-dimensional visualization and cerebrospinal fluid suppression compared to two-dimensional flair at 3 tesla
    Chagla, Gulzar Hameed
    Busse, Reed F.
    Sydnor, Ryan
    Rowley, Howard A.
    Turski, Patrick A.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (08) : 547 - 551
  • [24] Fast fluid-attenuated inversion-recovery imaging: first experience with a 3D version in epilepsy
    Wieshmann, UC
    Barker, GJ
    Symms, MR
    Bartlett, PA
    Stevens, JM
    Shorvon, SD
    NEURORADIOLOGY, 1998, 40 (08) : 483 - 489
  • [25] Diagnostic value of three-dimensional cube fluid attenuated inversion recovery imaging and its axial MIP reconstruction in multiple sclerosis
    Zamzam, Alaa Elsayed Abdelkader
    Aboukhadrah, Rania Sobhy
    Khali, Mohammed Mohammed
    Khodair, Sameh Ahmed Zaki
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01):
  • [26] Diagnostic value of three-dimensional cube fluid attenuated inversion recovery imaging and its axial MIP reconstruction in multiple sclerosis
    Alaa Elsayed Abdelkader Zamzam
    Rania Sobhy Aboukhadrah
    Mohammed Mohammed Khali
    Sameh Ahmed Zaki Khodair
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [27] Analysis of the 3-Dimensional Fluid-Attenuated Inversion-Recovery (3D-FLAIR) Sequence in Idiopathic Sudden Sensorineural Hearing Loss
    Berrettini, Stefano
    Seccia, Veronica
    Fortunato, Susanna
    Forli, Francesca
    Bruschini, Luca
    Piaggi, Paolo
    Canapicchi, Raffaello
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2013, 139 (05) : 456 - 464
  • [28] Multiple sclerosis lesion detect in the brain: A comparison of fast fluid-attenuated inversion recovery and conventional T2-weighted dual spin echo
    GawneCain, ML
    ORiordan, JI
    Thompson, AJ
    Moseley, IF
    Miller, DH
    NEUROLOGY, 1997, 49 (02) : 364 - 370
  • [29] Improved cortical, cervical cord and optic nerve lesion detection in multiple sclerosis with a prototype 3D Turbo Spin Echo MRI sequence for Double Inversion Recovery
    Costagli, M.
    Lapucci, C.
    Zaca, D.
    Bruschi, N.
    Schiavi, S.
    Castellan, L.
    Stemmer, A.
    Roccatagliata, L.
    Inglese, M.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (2_SUPPL) : 474 - 475
  • [30] Multi-contrast MR imaging at 7T in multiple sclerosis: highest lesion detection in cortical grey matter with 3D fluid-attenuated inversion recovery
    Kilsdonk, I. D.
    de Graaf, W. L.
    Soriano, A. Lopez
    Zwanenburg, J. J.
    Visser, F.
    Kuijer, J. P. A.
    Geurts, J. J. G.
    Pouwels, P. J. W.
    Polman, C. H.
    Castelijns, J. A.
    Luijten, P. R.
    Barkhof, F.
    Wattjes, M. P.
    MULTIPLE SCLEROSIS JOURNAL, 2012, 18 : 9 - 9