Custom 3D-printed applicators for high dose-rate brachytherapy in skin cancer

被引:11
|
作者
Membrive Conejo, Ismael [1 ,2 ]
Pera Cegarra, Oscar [1 ,2 ]
Foro Arnalot, Palmira [1 ,2 ,3 ]
Reig Castillejo, Ana [1 ,2 ]
Rodriguez de Dios, Nuria [1 ,2 ,3 ]
Sanz Latiesas, Xavier [1 ,2 ,3 ]
Pujol Vallverdu, Ramon M. [2 ,4 ,5 ]
Quera Jordana, Jaume [1 ,2 ,3 ]
Fernandez-Velilla Cepria, Enric [1 ,2 ]
Algara Munoz, Victor [6 ]
Algara Lopez, Manuel [1 ,2 ,5 ]
机构
[1] Hosp Mar, Radiat Oncol Dept, Parc Salut Mar,Passeig Marftim 25, Barcelona 08003, Spain
[2] Inst Hosp Mar Investigac Med Barcelona, Barcelona, Spain
[3] Pompeu Fabra Univ, Barcelona, Spain
[4] Hosp Mar, Dermatol Dept, Parc Salut Mar, Barcelona, Spain
[5] Univ Autonoma Barcelona Barcelona, Barcelona, Spain
[6] Univ Politecn Catalunya Barcelona, Barcelona, Spain
关键词
3D print; Skin cancer; Plesiotherapy; Brachytherapy; BASAL-CELL; RECOMMENDATIONS; RADIOTHERAPY; IMIQUIMOD; THERAPY;
D O I
10.1016/j.brachy.2021.05.164
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: This paper describes the protocol for the development of 3D-printed custom applicators in treating skin carcinoma, the evaluation of the materials used, and the methods for segmentation and rendering of the applicators. MATERIAL AND METHODS: The segmentation and rendering process for the applicator had six phases: (i) determination of the volume of the lesion using a computed tomography (CT) scan; (ii) delineation of the patient surface, using the same CT images; (iii) creation of the applicator in the planner and segmentation of the mold; (iv) preliminary dosimetry and establishment of the route of the catheter from the brachytherapy unit; (v) creation of the 3D applicator using specialized software; and (vi) applicator printing. Following this process, the patient returned for a second CT to undergo the definitive dosimetry with the applicator in place. Radiation therapy was then administered. RESULTS: We made a total of 16 applicators. Only three applicators had to be remade, two due to an error in the infill and the other due to incorrect catheter geometry. In all cases, correct coverage of the planning target volume was achieved with the prescribed isodose. CONCLUSIONS: The creation of custom molds in plesiotherapy for skin cancer with 3D printing is feasible. Compared to manual methods, 3D printing increases precision in applicator geometry and optimization of the dosimetry. (c) 2021 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1257 / 1264
页数:8
相关论文
共 50 条
  • [21] High dose-rate brachytherapy in the treatment of prostate cancer
    Mendez, Lucas C.
    Morton, Gerard C.
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2018, 7 (03) : 357 - 370
  • [22] Validation of 3D printing materials for high dose-rate brachytherapy using ionisation chamber and custom phantom
    Pera, Oscar
    Membrive, Ismael
    Lambisto, Daniel
    Quera, Jaume
    Fernandez-Velilla, Enric
    Foro, Palmira
    Reig, Ana
    Rodriguez, Nuria
    Sanz, Javier
    Algara, Victor
    Algara, Manuel
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [23] DOSE DETERMINATION IN HIGH DOSE-RATE BRACHYTHERAPY
    HOUDEK, PV
    SCHWADE, JG
    WU, XD
    PISCIOTTA, V
    FIEDLER, JA
    SERAGO, CF
    MARKOE, AM
    ABITBOL, AA
    LEWIN, AA
    BRAUNSCHWEIGER, PG
    SKLAR, MD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (04): : 795 - 801
  • [24] High dose rate brachytherapy with customized applicators for malignant facial skin lesions
    Jumeau, R.
    Renard-Oldrini, S.
    Courrech, F.
    Buchheit, I.
    Oldrini, G.
    Vogin, G.
    Peiffert, D.
    CANCER RADIOTHERAPIE, 2016, 20 (05): : 341 - 346
  • [25] clinical outcomes of using 3D-printed applicators for HDR brachytherapy in gynecological malignancy
    Sittiwong, W.
    Dankulchai, P.
    Puangragsa, U.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1935 - S1936
  • [26] Design, Production and Evaluation of Personalized 3D-Printed IC-Brachytherapy Applicators
    Basaric, B.
    Morgan, L.
    Engelberts, C.
    Crocker, M.
    Orbovic, R.
    Orton, E.
    Robar, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E737 - E737
  • [27] A Deep-Learning Approach Toward Automated Digitization of High Dose-Rate Brachytherapy Applicators
    Jung, H.
    Klages, P.
    Shen, C.
    Gonzalez, Y.
    Albuquerque, K.
    Jia, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E572 - E572
  • [28] High dose rate brachytherapy using custom mold surface applicators for the treatment of cutaneous lymphoma
    Albert, M.
    Maguire, M. S.
    Wang, Z.
    Gagne, R. N.
    Luo, C.
    Zhu, Y.
    Dugal, R.
    Stewart, A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S569 - S569
  • [29] Study of dose dependence on density in planar 3D-printed applicators for HDR Ir192 surface brachytherapy
    Bienvenido, Rafael
    Quinones, Luis Angel
    Perez, Joaquin
    Castro, Ignacio
    Gutierrez, Lucia
    Lopez, Juan de Dios
    Botana, Javier
    Iborra, Maria Amparo
    BRACHYTHERAPY, 2023, 22 (02) : 250 - 259
  • [30] Custom 3D-Printed Interstitial Applicator Template Library for HDR Brachytherapy
    Gonzalez, Y.
    Hrycushko, B.
    Jia, X.
    Visak, J.
    Dunton, N.
    Smith, L.
    Nwachukwu, C.
    Albuquerque, K.
    Chiu, T.
    MEDICAL PHYSICS, 2022, 49 (06) : E185 - E186