The Application of Iodine Quantitative Information Obtained by Dual-Source Dual-Energy Computed Tomography on Chemoradiotherapy Effect Monitoring for Cervical Cancer: A Preliminary Study

被引:14
|
作者
Jiang, Changqin [1 ]
Yang, Pin [1 ]
Lei, Junqiang [1 ,2 ]
Li, Jinkui [2 ]
Yan, Kun [1 ]
Li, Feilong [1 ]
Yan, Ruifeng [1 ,2 ]
Xia, Lichao [1 ,2 ]
机构
[1] Lanzhou Univ, Clin Med Coll 1, Hosp 1, Lanzhou, Gansu, Peoples R China
[2] Lanzhou Univ, Radiol Dept, Hosp 1, 222 Tianshui S Rd, Lanzhou 730000, Gansu, Peoples R China
关键词
cervical cancer; radiochemotherapy; dual energy; iodine mapping; computed tomography; SQUAMOUS-CELL CARCINOMA; PROGNOSTIC-FACTORS; RADIATION-THERAPY; UTERINE CERVIX; CONCURRENT CHEMORADIOTHERAPY; COMBINED CHEMORADIATION; TREATMENT FAILURE; CT PERFUSION; TUMOR; SURVIVAL;
D O I
10.1097/RCT.0000000000000603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of the study is to investigate the potential contribution of the iodine quantitative parameters of dual-phase dual-energy computed tomography (DECT) scanning for chemoradiotherapy (CRT) response monitoring for cervical cancer. Methods: Patients whowere pathologically certified having cervical cancer and intended for concurrent radiotherapy and chemotherapy were prospectively included in our study. Contrast-enhanced DECT scanning was performed before CRT, which was repeated after 1 month of therapy, using a dual-source CT scanner onset. Changes in tumor size were assessed according to RECIST 1.0. Quantification of volume-normalized iodine uptake (mg/mL) was measured in dual phases and was standardized using the iodine uptake in the iliac artery. The decreased ratio of the standard iodine uptake was calculated and compared with the tumor size for the evaluation of the CRT effect. Data were analyzed using the statistics software SPSS version 19.0. Twenty women who performed normal pelvic contrast-enhanced CT scanning were randomly chosen as the control group for the radiation dose comparison with the dual-energy group. Results: A total of 21 patients who completed therapeutic courses and performed the contrast-enhanced CT scanning were subsequently evaluated. According to RECIST 1.0, 15 cases were classified into the regression (R, including 5 completed regression cases and 10 partial regression cases) group. The remaining 6 cases were classified into the nonregression (NR, including 6 stable disease cases) group. The iodine value decreased ratio in the arterial phase (standardized iodine in arterial phase [SAI]) of the partial regression group was significantly higher than that of the stable disease group (P < 0.01), and there was no significant difference in the venous phase (P > 0.05). In a general quantitative comparison between the R group and the NR group before CRT, we controlled for the maximum diameter, age, iodine uptake in the arterial phase before CRT (pre-SAI), iodine uptake in the venous phase before CRT, and cell differentiated level, and we ultimately found no significant statistical differences except for the pre-SAI. In other words, the iodine value in the arterial phase of the R group before CRT was significantly higher than that of the NR group (P < 0.01). When the pre-SAI was 0.345, the area under the curve was 0.875 for therapeutic effect prediction. The mean effective dose was 5.63 +/- 1.68 mSv for the DECT group and 5.37 +/- 1.82 mSv for the control group (t = -1.137, P = 0.262), which showed no statistical difference in the radiation dose between the 2 scanning methods. Conclusions: The iodinemapping can be used to help evaluate the response effectively on the basis of tumor size change and can also be helpful in predicting the radiochemotherapy outcome for cervical cancer. The dual-phase DECT scanning did not increase the radiation dose and provided more valuable information, and thus, it was suitable for promotion in clinical application.
引用
收藏
页码:737 / 745
页数:9
相关论文
共 50 条
  • [41] Pre-operative Percutaneous Nephrolithotripsy Characterisation of Kidney Stones with Second-Generation Dual-Source Dual-Energy Computed Tomography
    Ali, D. K. Mella Mohd
    Mahmud, Mohd Hafizi
    Mohamad, Noor Shafini
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2020, 27 (05): : 43 - 52
  • [42] Comparison of dual-source computed tomography (CT) dual-energy angiography with conventional 3D imaging towards caudomedial vessels
    Li, Daowei
    Liu, Na
    Ma, Qiang
    He, Dan
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (12): : 5445 - 5449
  • [43] Re: Urinary Stone Differentiation in Patients with Large Body Size Using Dual-Energy Dual-Source Computed Tomography Editorial Comment
    Assimos, Dean G.
    JOURNAL OF UROLOGY, 2013, 189 (05): : 1767 - 1767
  • [44] Method for determining the half-value layer in computed tomography scans using a real-time dosimeter: Application to dual-source dual-energy acquisition
    Matsubara, Kosuke
    Nagata, Hiroji
    Okubo, Rena
    Takata, Tadanori
    Kobayashi, Masanao
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 227 - 231
  • [45] Crohn's Disease Activity Quantified by Iodine Density Obtained From Dual-Energy Computed Tomography Enterography
    Dane, Bari
    Duenas, Sean
    Han, Joseph
    O'Donnell, Thomas
    Ream, Justin
    Chang, Shannon
    Megibow, Alec
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (02) : 242 - 247
  • [46] Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners
    Almeida, Isabel P.
    Schyns, Lotte E. J. R.
    Ollers, Michel C.
    van Elmpt, Wouter
    Parodi, Katia
    Landry, Guillaume
    Verhaegen, Frank
    MEDICAL PHYSICS, 2017, 44 (01) : 171 - 179
  • [47] Quantification of Cisplatin Using a Modified 3-Material Decomposition Algorithm at Third-Generation Dual-Source Dual-Energy Computed Tomography An Experimental Study
    Sofue, Keitaro
    Itoh, Toshihide
    Takahashi, Satoru
    Schmidt, Bernhard
    Shimada, Ryuji
    Negi, Noriyuki
    Sugimura, Kazuro
    Murakami, Takamichi
    INVESTIGATIVE RADIOLOGY, 2018, 53 (11) : 673 - 680
  • [48] Dual-Energy Computed Tomography for the Diagnosis of Mediastinal Lymph Node Metastasis in Lung Cancer Patients: A Preliminary Study
    Hu, Xiaoli
    Gu, Qianbiao
    Zhang, Kun
    Deng, Dong
    Li, Lei
    Li, Ping
    Shen, Hongrong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 490 - 494
  • [49] Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
    Han, D.
    Xie, X. J.
    Wen, L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (02): : 159 - 163
  • [50] Virtual Unenhanced Images of the Abdomen With Second-Generation Dual-Source Dual-Energy Computed Tomography Image Quality and Liver Lesion Detection
    De Cecco, Carlo Nicola
    Darnell, Anna
    Macias, Napoleon
    Ramon Ayuso, Juan
    Rodriguez, Sonia
    Rimola, Jordi
    Pages, Mario
    Garcia-Criado, Angeles
    Rengo, Marco
    Laghi, Andrea
    Ayuso, Carmen
    INVESTIGATIVE RADIOLOGY, 2013, 48 (01) : 1 - 9