The Application of Iodine Quantitative Information Obtained by Dual-Source Dual-Energy Computed Tomography on Chemoradiotherapy Effect Monitoring for Cervical Cancer: A Preliminary Study

被引:14
|
作者
Jiang, Changqin [1 ]
Yang, Pin [1 ]
Lei, Junqiang [1 ,2 ]
Li, Jinkui [2 ]
Yan, Kun [1 ]
Li, Feilong [1 ]
Yan, Ruifeng [1 ,2 ]
Xia, Lichao [1 ,2 ]
机构
[1] Lanzhou Univ, Clin Med Coll 1, Hosp 1, Lanzhou, Gansu, Peoples R China
[2] Lanzhou Univ, Radiol Dept, Hosp 1, 222 Tianshui S Rd, Lanzhou 730000, Gansu, Peoples R China
关键词
cervical cancer; radiochemotherapy; dual energy; iodine mapping; computed tomography; SQUAMOUS-CELL CARCINOMA; PROGNOSTIC-FACTORS; RADIATION-THERAPY; UTERINE CERVIX; CONCURRENT CHEMORADIOTHERAPY; COMBINED CHEMORADIATION; TREATMENT FAILURE; CT PERFUSION; TUMOR; SURVIVAL;
D O I
10.1097/RCT.0000000000000603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of the study is to investigate the potential contribution of the iodine quantitative parameters of dual-phase dual-energy computed tomography (DECT) scanning for chemoradiotherapy (CRT) response monitoring for cervical cancer. Methods: Patients whowere pathologically certified having cervical cancer and intended for concurrent radiotherapy and chemotherapy were prospectively included in our study. Contrast-enhanced DECT scanning was performed before CRT, which was repeated after 1 month of therapy, using a dual-source CT scanner onset. Changes in tumor size were assessed according to RECIST 1.0. Quantification of volume-normalized iodine uptake (mg/mL) was measured in dual phases and was standardized using the iodine uptake in the iliac artery. The decreased ratio of the standard iodine uptake was calculated and compared with the tumor size for the evaluation of the CRT effect. Data were analyzed using the statistics software SPSS version 19.0. Twenty women who performed normal pelvic contrast-enhanced CT scanning were randomly chosen as the control group for the radiation dose comparison with the dual-energy group. Results: A total of 21 patients who completed therapeutic courses and performed the contrast-enhanced CT scanning were subsequently evaluated. According to RECIST 1.0, 15 cases were classified into the regression (R, including 5 completed regression cases and 10 partial regression cases) group. The remaining 6 cases were classified into the nonregression (NR, including 6 stable disease cases) group. The iodine value decreased ratio in the arterial phase (standardized iodine in arterial phase [SAI]) of the partial regression group was significantly higher than that of the stable disease group (P < 0.01), and there was no significant difference in the venous phase (P > 0.05). In a general quantitative comparison between the R group and the NR group before CRT, we controlled for the maximum diameter, age, iodine uptake in the arterial phase before CRT (pre-SAI), iodine uptake in the venous phase before CRT, and cell differentiated level, and we ultimately found no significant statistical differences except for the pre-SAI. In other words, the iodine value in the arterial phase of the R group before CRT was significantly higher than that of the NR group (P < 0.01). When the pre-SAI was 0.345, the area under the curve was 0.875 for therapeutic effect prediction. The mean effective dose was 5.63 +/- 1.68 mSv for the DECT group and 5.37 +/- 1.82 mSv for the control group (t = -1.137, P = 0.262), which showed no statistical difference in the radiation dose between the 2 scanning methods. Conclusions: The iodinemapping can be used to help evaluate the response effectively on the basis of tumor size change and can also be helpful in predicting the radiochemotherapy outcome for cervical cancer. The dual-phase DECT scanning did not increase the radiation dose and provided more valuable information, and thus, it was suitable for promotion in clinical application.
引用
收藏
页码:737 / 745
页数:9
相关论文
共 50 条
  • [1] Dual-source dual-energy computed tomography angiography for active gastrointestinal bleeding: A preliminary study
    Sun, H.
    Xue, H. -D.
    Wang, Y. -N.
    Qian, J. -M.
    Yu, J. -C.
    Zhu, F.
    Zhu, H. -D.
    Jin, Z. -Y.
    Li, X. -G.
    CLINICAL RADIOLOGY, 2013, 68 (02) : 139 - 147
  • [2] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Satoshi Okayama
    Ayako Seno
    Tsunenari Soeda
    Yasuhiro Takami
    Rika Kawakami
    Satoshi Somekawa
    Ken-ichi Ishigami
    Yukiji Takeda
    Hiroyuki Kawata
    Manabu Horii
    Shiro Uemura
    Yoshihiko Saito
    The International Journal of Cardiovascular Imaging, 2012, 28 : 901 - 909
  • [3] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Okayama, Satoshi
    Seno, Ayako
    Soeda, Tsunenari
    Takami, Yasuhiro
    Kawakami, Rika
    Somekawa, Satoshi
    Ishigami, Ken-ichi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Uemura, Shiro
    Saito, Yoshihiko
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 901 - 909
  • [4] Accuracy of spectral curves at different phantom sizes and iodine concentrations using dual-source dual-energy computed tomography
    Sato, Kazuhiro
    Kageyama, Ryota
    Sawatani, Yuta
    Takano, Hirokazu
    Kayano, Shingo
    Takane, Yumi
    Saito, Haruo
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (01) : 103 - 116
  • [5] Accuracy of spectral curves at different phantom sizes and iodine concentrations using dual-source dual-energy computed tomography
    Kazuhiro Sato
    Ryota Kageyama
    Yuta Sawatani
    Hirokazu Takano
    Shingo Kayano
    Yumi Takane
    Haruo Saito
    Physical and Engineering Sciences in Medicine, 2021, 44 : 103 - 116
  • [6] Unsupervised deep learning based image outpainting for dual-source, dual-energy computed tomography
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [7] Evaluation of Advanced Gastric Carcinoma with Monoenergetic Spectrum Curve of Dual-source Dual-energy Computed Tomography
    Li-mei Pei
    Gao-feng Shi
    Run-ze Wu
    Ru-xun Li
    Yu Du
    Chinese Medical Sciences Journal, 2013, 28 (01) : 64 - 64
  • [8] The value of performing dual-source dual-energy computed tomography in analysis strategy for urinary mixed stone
    Wang, Xiao-Gang
    Fan, Bo
    Wang, Wei
    Jin, Yi-Ying
    Jin, Yan
    Yang, Zhi-Qiang
    Li, Xian-Cheng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2017, 10 (02): : 1519 - 1528
  • [9] Separation of Hepatic Iron and Fat by Dual-Source Dual-Energy Computed Tomography Based on Material Decomposition: An Animal Study
    Ma, Jing
    Song, Zhi-Qiang
    Yan, Fu-Hua
    PLOS ONE, 2014, 9 (10):
  • [10] Interscanner and Intrascanner Comparison of Virtual Unenhanced Attenuation Values Derived From Twin Beam Dual-Energy and Dual-Source, Dual-Energy Computed Tomography
    Obmann, Markus M.
    Kelsch, Vanessa
    Cosentino, Aurelio
    Hofmann, Verena
    Boll, Daniel T.
    Benz, Matthias R.
    INVESTIGATIVE RADIOLOGY, 2019, 54 (01) : 1 - 6