Near-Infrared Fiber Imager for the VLTI

被引:1
|
作者
Neuhaeuser, Ralph [1 ,7 ]
Tuennermann, Andreas [2 ]
Hempel, Marc [1 ,7 ]
Stecklum, Bringfried [3 ]
Ruske, Jena-Peter [4 ]
Guenther, Eike [3 ]
Hatzes, Artie [3 ]
Chini, Rolf [5 ]
Lemke, Roland [5 ]
Wuchterl, Guenther [1 ,7 ]
von der Luehe, Oskar [6 ]
机构
[1] Inst Astrophys, Schillergasschen 2, D-07745 Jena, Germany
[2] Univ Jena, Inst Appl Phys, D-07745 Jena, Germany
[3] Thuringer Landessternwarte Tautenburg, D-07778 Tautenburg, Germany
[4] GC Tec, D-07745 Jena, Germany
[5] Ruhr Univ Bochum, Astron Inst, D-44780 Bochum, Germany
[6] Kiepenheuer Inst Sonnenphys, D-79104 Freiberg, Germany
[7] Univ Sternwarte, D-07745 Jena, Germany
来源
POWER OF OPTICAL/IR INTERFEROMETRY: RECENT SCIENTIFIC RESULTS AND 2ND GENERATION INSTRUMENTATION | 2008年
关键词
D O I
10.1007/978-3-540-74256-2_49
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
For detection of massive close-in exo-planets around other stars, a contrast of similar to 0.3% is sufficient and can be achieved with state-of-the-art single-mode fibers as spatial filter. For lower-mass planets, much higher accuracy is neccessary. Apart from the atmosphere, there are several sources of noise which degrade the phase stability of interferometers based on bulk optics by changes in the optical path. For direct detection of low-mass exo-planets and for direct observation of convection on giant stars, our two main science goals, as well as for secondary science goals such as lower-mass faint circumstellar disks around both nearby low-mass stars as well as more distant high-mass stars and for the direct detection of close spectroscopic binary (T Tauri) stars and to follow their orbits for direct dynamical mass determination, we need more than two apertures to fill the uv-plane, again very complicated with bulk-optics. Integrated optics allows to solve these problems and to minimize the components. We have experiences in the development and fabrication of integrated-optical circuits and modulators in various wavelength ranges, i.e. from visible to the telecommunication band, as well as integrated-optical sensor systems like interferometers. Starting from two channel interferometers for the J-band at 1.55 mu m based on Lithiumniobat, we will develop multi-channel-interferometer systems for longer wavelengths. Such systems with new materials and fibers for the near- and thermal infrared can then be used, e.g., for 2nd Gen VLTI instrumentation.
引用
收藏
页码:419 / 429
页数:11
相关论文
共 50 条
  • [41] Pinpointing the near-infrared location of Sgr A* by correcting optical distortion in the NACO imager
    Plewa, P. M.
    Gillessen, S.
    Eisenhauer, F.
    Ott, T.
    Pfuhl, O.
    George, E.
    Dexter, J.
    Habibi, M.
    Genzel, R.
    Reid, M. J.
    Menten, K. M.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2015, 453 (03) : 3234 - 3244
  • [42] Using the near infrared VLTI instrument AMBER
    Petrov, RG
    Malbet, F
    Weigelt, G
    Lisi, F
    Puget, P
    Antonelli, P
    Beckmann, U
    Lagarde, S
    Lecoarer, E
    Robbe-Dubois, S
    Duvert, G
    Gennari, S
    Chelli, A
    Dugué, M
    Rousselet-Perraut, K
    Vannier, M
    Mourard, D
    INTERFEROMETRY FOR OPTICAL ASTRONOMY II, PTS 1 AND 2, 2003, 4838 : 924 - 933
  • [43] A near-infrared colloidal quantum dot imager with monolithically integrated readout circuitry
    Liu, Jing
    Liu, Peilin
    Chen, Dengyang
    Shi, Tailong
    Qu, Xixi
    Chen, Long
    Wu, Tong
    Ke, Jiangping
    Xiong, Kao
    Li, Mingyu
    Song, Haisheng
    Wei, Wei
    Cao, Junkai
    Zhang, Jianbing
    Gao, Liang
    Tang, Jiang
    NATURE ELECTRONICS, 2022, 5 (07) : 443 - 451
  • [44] Miniaturized visible near-infrared hyperspectral imager for remote-sensing applications
    Warren, Christopher P.
    Even, Detlev
    Pfister, William
    Nakanishi, Keith
    Velasco, Arleen
    Breitwieser, David
    Yee, Selwyn
    Naungayan, Joseph
    OPTICAL ENGINEERING, 2012, 51 (11)
  • [45] The Gemini Near-Infrared Imager (NIRI): A discussion of its design features and performance
    Hodapp, KW
    Irwin, EM
    Yamada, H
    Chung, R
    Fletcher, K
    INSTRUMENT DESIGN AND PERFORMANCE FOR OPTICAL/INFRARED GROUND-BASED TELESCOPES, PTS 1-3, 2003, 4841 : 869 - 880
  • [46] AMBER:: a near infrared focal instrument for the VLTI
    Petrov, RG
    Malbet, F
    Richichi, A
    Hofmann, KH
    Mourard, D
    Agabi, K
    Antonelli, P
    Aristidi, E
    Baffa, C
    Beckmann, U
    Berio, P
    Bresson, Y
    Cassaing, F
    Chelli, A
    Dreiss, A
    Dugué, M
    Duvert, G
    Forveille, T
    Gennari, S
    Geng, M
    Glentzlin, A
    Kamm, D
    Lagarde, S
    Lecoarer, E
    Lecontel, D
    Lisi, F
    Lopez, B
    Marconi, A
    Mars, G
    Martinot-Lagarde, G
    Mekarnia, D
    Monin, JL
    Moullet, D
    Puget, P
    Rabbia, Y
    Rebattu, S
    Reynaud, F
    Robbe-Dubois, S
    Rousselet-Perraut, K
    Sacchettini, M
    Salinari, P
    Schoeller, M
    Tallon-Bosc, I
    Vannier, M
    Weigelt, G
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE IV PHYSIQUE ASTROPHYSIQUE, 2001, 2 (01): : 67 - 77
  • [47] The Qualitative Analysis of Far-infrared Fiber by Near-infrared Spectroscopy
    Guan, Yu
    Zhang, Yi
    ADVANCES IN MATERIALS AND MATERIALS PROCESSING, PTS 1-3, 2013, 652-654 : 1441 - 1444
  • [48] FIBER OPTIC NEAR-INFRARED SPECTROSCOPY IN THE REFINING INDUSTRY
    FOULK, SJ
    DESIMAS, BE
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (4-5): : 292 - 294
  • [49] POLYMER OPTICAL-FIBER FOR NEAR-INFRARED USE
    TAKEZAWA, Y
    OHARA, S
    JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 49 (01) : 169 - 173
  • [50] Near-infrared fluorescent dyes for fiber optic sensing
    Patonay, G
    Kim, JS
    Medou-Ovono, M
    Strekowski, L
    17TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2, 2005, 5855 : 495 - 498