Risk Factors for Corneal Infiltrative Events during Continuous Wear of Silicone Hydrogel Contact Lenses

被引:74
|
作者
Szczotka-Flynn, Loretta [1 ,2 ]
Lass, Jonathan H. [1 ,2 ]
Sethi, Ajay [3 ]
Debanne, Sara [4 ]
Benetz, Beth Ann [1 ,2 ]
Albright, Matthew [1 ,2 ]
Gillespie, Beth [1 ,2 ]
Kuo, Jana [1 ,2 ]
Jacobs, Michael R. [4 ]
Rimm, Alfred [5 ]
机构
[1] Univ Hosp, Inst Eye, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Ophthalmol & Visual Sci, Cleveland, OH 44106 USA
[3] Univ Wisconsin, Dept Populat Hlth Sci, Madison, WI USA
[4] Case Western Reserve Univ, Dept Pathol, Cleveland, OH 44106 USA
[5] Case Western Reserve Univ, Dept Epidemiol & Biostat, Cleveland, OH 44106 USA
关键词
EXTENDED-WEAR; MICROBIAL KERATITIS; STAPHYLOCOCCUS-EPIDERMIDIS; DISPOSABLE HYDROGELS; EPITHELIAL-CELLS; ADVERSE EVENTS; OCULAR SURFACE; CARE SOLUTIONS; COLONIZATION; BACTERIA;
D O I
10.1167/iovs.10-5456
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. This study determined which microbiologic, clinical, demographic, and behavioral factors are associated with corneal infiltrative events (CIEs) during continuous wear of silicone hydrogel (SH) contact lenses. METHODS. Subjects (n = 205) were fitted with lotrafilcon A lenses for continuous wear and observed for 1 year. The main exposures of interest were corneal staining and bacterial lens contamination. Kaplan-Meier (KM) plots were used to estimate the cumulative unadjusted probability of remaining CIE free, and Cox proportional hazards regression was used to model the hazard of having a CIE, as a function of key predictor variables. RESULTS. The KM-unadjusted cumulative probability of remaining CIE free was 73.3%. Approximately 53% of subjects had repeated episodes of corneal staining (mild or greater), and 11.3% had repeated episodes of moderate or greater corneal staining. Corneal staining was not associated with the development of a CIE. The frequency of substantial bacterial bioburden on worn lenses at the time of a CIE was 64.7%, compared with only 12.2% during uncomplicated wear. The presence of substantial lens bacterial bioburden was associated with the development of a CIE (adjusted hazards ratio [HR], 8.66; 95% confidence interval [CI], 2.88-26.01). Smoking was also associated with a CIE (adjusted HR, 4.13; 95% CI, 1.27-13.45). CONCLUSIONS. Corneal staining is common during continuous wear of SH lenses, but it is not associated with the development of a CIE. Smoking and substantial lens bacterial bioburden pose prominent risks of a CIE. In this study, more than 70% of the total risk of CIE in those with substantial lens bioburden is attributable to this exposure. (ClinicalTrials.gov number, NCT00727402). (Invest Ophthalmol Vis Sci. 2010; 51: 5421-5430) DOI: 10.1167/iovs.10-5456
引用
收藏
页码:5421 / 5430
页数:10
相关论文
共 50 条
  • [31] Long-term effects of the daily wear of senofilcon A silicone hydrogel contact lenses on corneal and conjunctival tissues
    Guillon, Michel
    Maissa, Cecile
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2010, 81 (12) : 680 - 687
  • [32] Thickness changes in the corneal epithelium and Bowman’s layer after overnight wear of silicone hydrogel contact lenses
    Fan Lu
    Aizhu Tao
    Weiwei Tao
    Xiran Zhuang
    Meixiao Shen
    BMC Ophthalmology, 18
  • [33] Thickness changes in the corneal epithelium and Bowman's layer after overnight wear of silicone hydrogel contact lenses
    Lu, Fan
    Tao, Aizhu
    Tao, Weiwei
    Zhuang, Xiran
    Shen, Meixiao
    BMC OPHTHALMOLOGY, 2018, 18
  • [34] In Response: Changes in Ultraviolet Transmittance of Hydrogel and Silicone Hydrogel Contact Lenses Induced by Wear
    Uchechukwu, Osuagwu L.
    Ogbuehi, Kelechi C.
    Almubrad, Turki M.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (04): : 252 - 254
  • [35] Changes in Ultraviolet Transmittance of Hydrogel and Silicone-Hydrogel Contact Lenses Induced by Wear
    Osuagwu, Uchechukwu L.
    Ogbuehi, Kelechi C.
    AlMubrad, Turki M.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (01): : 28 - 36
  • [36] Association of a corneal ulcer with extended wear of new generation silicone hydrogel lenses
    Primo, Ty E.
    McReynolds, Michelle
    Connor, Charles G.
    Optometry and Vision Science, 2000, 77 (12 SUPPL.)
  • [37] Are Silicone Hydrogel Contact Lenses More Comfortable Than Hydrogel Contact Lenses?
    Guillon, Michel
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 86 - 92
  • [38] Contact Lens-Related Adverse Events and the Silicone Hydrogel Lenses and Daily Wear Care System Used
    Carnt, Nicole A.
    Evans, Victoria E.
    Naduvilath, Thomas J.
    Willcox, Mark D. P.
    Papas, Eric B.
    Frick, Kevin D.
    Holden, Brien A.
    ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (12) : 1616 - 1623
  • [39] Influence of environmental factors in the in vitro dehydration of hydrogel and silicone hydrogel contact lenses
    Martin-Montanez, Vicente
    Lopez-Miguel, Alberto
    Arroyo, Cristina
    Mateo, Maria E.
    Gonzalez-Meijome, Jose M.
    Calonge, Margarita
    Gonzalez-Garcia, Maria J.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2014, 102 (04) : 764 - 771
  • [40] Clinical characterization of corneal infiltrative events observed with soft contact lens wear
    Sweeney, DF
    Jalbert, I
    Covey, M
    Sankaridurg, PR
    Vajdic, C
    Holden, BA
    Sharma, S
    Ramachandran, L
    Willcox, MDP
    Rao, GN
    CORNEA, 2003, 22 (05) : 435 - 442