Applying Adult Ventilator-associated Pneumonia Bundle Evidence to the Ventilated Neonate

被引:32
|
作者
Weber, Carla D. [1 ]
机构
[1] Mercy Hosp, Dept Talent Dev & Optimizat, 1235 E Cherokee St, Springfield, MO 65804 USA
关键词
colostrum; neonatal oral care; neonatal ventilator-associated pneumonia; neonate; VAP bundle; INTENSIVE-CARE-UNIT; CRITICALLY-ILL PATIENTS; NOSOCOMIAL PNEUMONIA; ORAL CARE; RISK-FACTORS; GASTROESOPHAGEAL-REFLUX; INTUBATED PATIENTS; MOLECULAR ANALYSIS; ICU PATIENTS; COLONIZATION;
D O I
10.1097/ANC.0000000000000276
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background: Ventilator-associated pneumonia (VAP) in neonates can be reduced by implementing preventive care practices. Implementation of a group, or bundle, of evidence-based practices that improve processes of care has been shown to be cost-effective and to have better outcomes than implementation of individual single practices. Purpose: The purpose of this article is to describe a safe, effective, and efficient neonatal VAP prevention protocol developed for caregivers in the neonatal intensive care unit (NICU). Improved understanding of VAP causes, effects of care practices, and rationale for interventions can help reduce VAP risk to neonatal patients. Method: In order to improve care practices to affect VAP rates, initial and annual education occurred on improved protocol components after surveying staff practices and auditing documentation compliance. Findings/Results: In 2009, a tertiary care level III NICU in the Midwestern United States had 14 VAP cases. Lacking evidence-based VAP prevention practices for neonates, effective adult strategies were modified to meet the complex needs of the ventilated neonate. A protocol was developed over time and resulted in an annual decrease in VAP until rates were zero for 20 consecutive months from October 2012 to May 2014. Implications for Practice: This article describes a VAP prevention protocol developed to address care practices surrounding hand hygiene, intubation, feeding, suctioning, positioning, oral care, and respiratory equipment in the NICU. Implications for Research: Implementation of this VAP prevention protocol in other facilities with appropriate monitoring and tracking would provide broader support for standardization of care. Individual components of this VAP protocol could be studied to strengthen the inclusion of each; however, bundled interventions are often considered stronger when implemented as a whole.
引用
收藏
页码:178 / 190
页数:13
相关论文
共 50 条
  • [41] Ventilator-associated pneumonia
    Shaw, MJ
    CURRENT OPINION IN PULMONARY MEDICINE, 2005, 11 (03) : 236 - 241
  • [42] Ventilator-Associated Pneumonia
    Chant, Clarence
    CANADIAN JOURNAL OF HOSPITAL PHARMACY, 2006, 59 : 42 - 43
  • [43] Ventilator-associated pneumonia
    不详
    RESPIROLOGY, 2009, 14 : S51 - S58
  • [44] Ventilator-associated pneumonia
    Valencia, Mauricio
    Torres, Antoni
    CURRENT OPINION IN CRITICAL CARE, 2009, 15 (01) : 30 - 35
  • [45] Ventilator-associated pneumonia
    Dembinski, R.
    Rossaint, R.
    ANAESTHESIST, 2008, 57 (08): : 825 - 839
  • [46] Ventilator-associated pneumonia
    Otavio T. Ranzani
    Michael S. Niederman
    Antoni Torres
    Intensive Care Medicine, 2022, 48 : 1222 - 1226
  • [47] Ventilator-associated pneumonia
    Rosseau, S.
    Schuette, H.
    Suttorp, N.
    INTERNIST, 2013, 54 (08): : 954 - 962
  • [48] Ventilator-associated pneumonia
    Vincent, JL
    JOURNAL OF HOSPITAL INFECTION, 2004, 57 (04) : 272 - 280
  • [49] Ventilator-associated pneumonia
    Chastre, J
    Fagon, JY
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (07) : 867 - 903
  • [50] Ventilator-associated pneumonia
    Torres, A
    EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (06) : 1079 - 1080