Combined Twyman-Green and Mach-Zehnder interferometer for microlens testing

被引:59
|
作者
Reichelt, S [1 ]
Zappe, H [1 ]
机构
[1] Univ Freiburg, Lab Microopt, Inst Microsyst Technol, D-79110 Freiburg, Germany
关键词
D O I
10.1364/AO.44.005786
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new interferometer design for microlens testing is presented. The phase-shifting system combines the advantages of a Twyman-Green and a Mach-Zehnder interferometer and permits full characterization of the aberrations of microlenses as well as radius of curvature and focal length measurements. The Twyman-Green system is applied to surface testing in reflection (single reflection), whereas the Mach-Zehnder system is used for lens testing in transmission (single pass). Both measurements are performed without removal of the test part, allowing for combination of the results without confusion of the actual lens and without an azimuthal orientation error. The interterometer setup is explained, the test procedure is described, and experimental results are given. (c) 2005 Optical Society of America.
引用
收藏
页码:5786 / 5792
页数:7
相关论文
共 50 条
  • [41] Dynamic measurement of the corneal tear film with a Twyman-Green interferometer
    Micali, Jason D.
    Greivenkamp, John E.
    Primeau, Brian C.
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (05)
  • [42] Analysis and testing of a novel OADM based on FBG and Mach-Zehnder interferometer
    Huang, YL
    Dong, XF
    Li, J
    Dong, XY
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2005, 45 (02) : 156 - 158
  • [43] Wavefront aberration measurement technology for microlens using the Mach-Zehnder interferometer provided with a projected aperture
    Miyashita, T
    Hamanaka, K
    Kato, M
    Ishihara, S
    Sato, H
    Sato, E
    Morokuma, T
    INTERFEROMETRY XII: APPLICATIONS, 2004, 5532 : 117 - 127
  • [44] Comparative spectral tuning and fluctuation analysis of an all-fiber Mach-Zehnder interferometer and micro Mach-Zehnder interferometer
    Ramachandran, K.
    Kumar, Naveen
    JOURNAL OF OPTICS, 2021, 23 (11)
  • [45] THE USE OF A TWYMAN-GREEN TYPE INTERFEROMETER TO MEASURE DIFFUSIVITIES IN AN ELECTRODEPOSITION CELL
    OBRIEN, RN
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1957, 35 (08): : 932 - 934
  • [46] Bell's inequality for the Mach-Zehnder interferometer
    Johansen, LM
    PHYSICS LETTERS A, 1996, 219 (1-2) : 15 - 18
  • [47] Theory of the nonequilibrium electronic Mach-Zehnder interferometer
    Schneider, Martin
    Bagrets, Dmitry A.
    Mirlin, Alexander D.
    PHYSICAL REVIEW B, 2011, 84 (07)
  • [48] Explanation of Photon Navigation in the Mach-Zehnder Interferometer
    Pons, Dirk J.
    OPTICS, 2020, 1 (03):
  • [49] A GENERALIZED VECTOR THEORY OF THE MACH-ZEHNDER INTERFEROMETER
    BENNETT, FD
    KAHL, GD
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (02) : 71 - 80
  • [50] Entanglement and visibility at the output of a Mach-Zehnder interferometer
    Paris, Matteo G.A.
    Physical Review A. Atomic, Molecular, and Optical Physics, 1999, 59 (02):