Measurement of the Lid Margin Thickness in Meibomian Gland Dysfunction with Vernier Micrometer
被引:4
|
作者:
Zhu, Hua-Ying
论文数: 0引用数: 0
h-index: 0
机构:
Shanghai Univ Tradit Chinese Med, Dept Ophthalmol, Longhua Hosp, 725 South Wanping Rd, Shanghai 200032, Peoples R ChinaShanghai Univ Tradit Chinese Med, Dept Ophthalmol, Longhua Hosp, 725 South Wanping Rd, Shanghai 200032, Peoples R China
Zhu, Hua-Ying
[1
]
Liu, Xin-Quan
论文数: 0引用数: 0
h-index: 0
机构:
Shanghai Univ Tradit Chinese Med, Dept Ophthalmol, Longhua Hosp, 725 South Wanping Rd, Shanghai 200032, Peoples R ChinaShanghai Univ Tradit Chinese Med, Dept Ophthalmol, Longhua Hosp, 725 South Wanping Rd, Shanghai 200032, Peoples R China
Liu, Xin-Quan
[1
]
Yuan, Yuan-Zhi
论文数: 0引用数: 0
h-index: 0
机构:
Fudan Univ, Dept Ophthalmol, Zhongshan Hosp, Shanghai, Peoples R China
Fudan Univ, Ctr Evidence Based Med, Shanghai, Peoples R ChinaShanghai Univ Tradit Chinese Med, Dept Ophthalmol, Longhua Hosp, 725 South Wanping Rd, Shanghai 200032, Peoples R China
Yuan, Yuan-Zhi
[2
,3
]
Wang, Da-Hu
论文数: 0引用数: 0
h-index: 0
机构:
Shanghai Univ Tradit Chinese Med, Dept Ophthalmol, Longhua Hosp, 725 South Wanping Rd, Shanghai 200032, Peoples R ChinaShanghai Univ Tradit Chinese Med, Dept Ophthalmol, Longhua Hosp, 725 South Wanping Rd, Shanghai 200032, Peoples R China
Wang, Da-Hu
[1
]
机构:
[1] Shanghai Univ Tradit Chinese Med, Dept Ophthalmol, Longhua Hosp, 725 South Wanping Rd, Shanghai 200032, Peoples R China
[2] Fudan Univ, Dept Ophthalmol, Zhongshan Hosp, Shanghai, Peoples R China
[3] Fudan Univ, Ctr Evidence Based Med, Shanghai, Peoples R China
Lid margin thickness;
Meibomian gland dysfunction;
Meibum expressibility;
Vernier micrometer;
DRY EYE;
INTERNATIONAL WORKSHOP;
PREVALENCE;
ASSOCIATION;
POPULATION;
PRESSURE;
CHINESE;
D O I:
10.1007/s40123-021-00421-7
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
Introduction To investigate the lid margin thickness (LMT) from the posterior lash line to the mucocutaneous junction at the middle position in adults with and without meibomian gland dysfunction (MGD) by vernier micrometer (VM). Methods This is a cross-sectional, observational study. A hundred eyes from 100 volunteers aged 20 to 79, including 56 normal participants and 44 participants with MGD, were recruited. Measurements of the LMT by VM were performed by the same person. Results The mean age of 56 normal subjects (24 males and 32 females) and 44 MGD subjects (16 males and 28 females) was 40.0 +/- 13.2 years and 42.7 +/- 17.1 years, respectively. There was a significant difference in the upper LMT between normal and MGD subjects (1.36 +/- 0.25 vs. 1.60 +/- 0.27 mm, P < 0.001), but not in the lower LMT (1.0 +/- 0.23 vs. 1.10 +/- 0.28 mm, P = 0.07). In both normal and MGD subjects, the upper or lower LMT was significantly positively correlated with age (P < 0.05), and the upper LMT was greater than the lower LMT (P < 0.001). In addition, the lower LMT in MGD subjects was significantly positively correlated with meibum expressibility (r(s) = 0.35, P = 0.02). Conclusions The LMT was closely related to age and could be an important indicator for detecting MGD. Furthermore, we found that the upper LMT was greater than the lower LMT, and the lower LMT in MGD subjects seemed to be related to meibum expressibility.
机构:
Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, BrazilUniv Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
Pereira Gomes, Jose Alvaro
Rocha, Eduardo M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Ophthalmol Otorhinolaryngol & Head & Neck Su, BR-14049 Ribeirao Preto, SP, BrazilUniv Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
Rocha, Eduardo M.
de Freitas, Denise
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, BrazilUniv Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
de Freitas, Denise
Sullivan, David A.
论文数: 0引用数: 0
h-index: 0
机构:
Harvard Univ, Sch Med, Dept Ophthalmol, Cambridge, MA 02138 USAUniv Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil