Leadless cardiac pacemaker implantations after infected pacemaker system removals in octogenarians

被引:12
|
作者
Higuchi, Satoshi [1 ]
Okada, Ayako [2 ]
Shoda, Morio [1 ,2 ]
Yagishita, Daigo [1 ]
Saito, Satoshi [3 ]
Kanai, Miwa [1 ]
Kataoka, Shohei [1 ]
Yazaki, Kyoichiro [1 ]
Tabata, Hiroaki [2 ]
Kobayashi, Hideki [2 ]
Shoin, Wataru [2 ]
Okano, Takahiro [2 ]
Yoshie, Koji [2 ]
Ejima, Koichiro [1 ]
Kuwahara, Koichiro [2 ]
Hagiwara, Nobuhisa [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Cardiol, Kawada Cho,Shinjuku Ku 8-1, Tokyo 1628666, Japan
[2] Shinshu Univ, Sch Med, Dept Cardiovasc Med, 3-1-1 Asahi, Matsumoto, Nagano 3908621, Japan
[3] Tokyo Womens Med Univ, Dept Cardiovasc Surg, Shinjuku Ku, Kawada Cho 8-1, Tokyo 1628666, Japan
关键词
CARDIOVERTER-DEFIBRILLATOR; RISK-FACTORS; EXTRACTION; MANAGEMENT; SAFETY; TRENDS;
D O I
10.11909/j.issn.1671-5411.2021.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Management of pacemaker (PM) infections among advanced aged patients possesses particular clinical challenges due to higher rates of concurrent cardiovascular disease and medical comorbidities. Novel leadless cardiac pacemakers (LCPs) may provide new opportunities for better management options in this population, however, there is limited data especially in Asian populations to guide the decision making. Methods We reviewed 11 octogenarians (median age: 86 [minimum 82-maximum 90] years; male: 73%; median body mass index (BMI): 20.1 kg/m2) who received Micra Transcatheter Pacing System (Medtronic Inc, Minneapolis, MN) implantations following transvenous lead extractions (TLEs) for PM infections. Results All patients had more than two medical comorbidities (average 3.7 comorbidities). The indications for LCP implantations were atrioventricular block in four patients, atrial fibrillation bradycardia in five, and sinus node dysfunction in two. Eight patients (73%) were bridged with temporary pacing using active fixation leads (median interval of 14.0 days), while one with severe dementia underwent a concomitant LCP implantation and TLE during the same procedure. Successful TLEs and LCP implantations were successfully accomplished in all without any complications. The median time from the TLE procedure to discharge was 22 days (minimum 7-maximum 136). All patients remained free of infections during a mean follow-up period of 17.2 +/- 6.5 months. Conclusions LCP implantations were safe and effective after removing the entire infectious PM system in all octogenarians. The novel LCP technology may offer an alternative option for considering a re-implantation strategy after transvenous PM infections in elderly patients, particularly those with severe frailty and PM dependency.
引用
收藏
页码:505 / 513
页数:9
相关论文
共 50 条
  • [41] Deep vein thrombosis after leadless pacemaker implantation
    Hayashi, T.
    Shishido, K. S.
    Moriyama, N. M.
    Tobita, K. T.
    Murakami, M. M.
    Saito, S. S.
    EUROPEAN HEART JOURNAL, 2022, 43 : 479 - 479
  • [42] Anesthetic Management of a Patient With a Leadless Pacemaker Undergoing Cardiac Surgery
    Reddy, Sanhita
    Coletta, Joelle
    Mizuguchi, K. Annette
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (01) : 176 - 180
  • [43] Visualization and appearance of artifacts of leadless pacemaker systems in cardiac MRI
    Edlinger, Christoph
    Granitz, Marcel
    Paar, Vera
    Jung, Christian
    Pfeil, Alexander
    Eder, Sarah
    Wernly, Bernhard
    Kammler, Juergen
    Hergan, Klaus
    Hoppe, Uta C.
    Steinwender, Clemens
    Lichtenauer, Michael
    Kypta, Alexander
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 (13-14) : 427 - 435
  • [44] Leadless cardiac pacemaker implantation in patient with active tricuspid endocarditis
    Jacobs, Mathieu
    Bisson, Arnaud
    Bodin, Alexandre
    Babuty, Dominique
    Niro, Marjorie
    Clementy, Nicolas
    EUROPACE, 2021, 23 (11): : 1794 - 1794
  • [45] The learning curve associated with the implantation of the nanostim leadless cardiac pacemaker
    Beurskens, N. E. G.
    Tjong, F. V. Y.
    Neuzil, P.
    Defaye, P.
    Delnoy, P. P.
    Ip, J.
    Garcia Guerrero, J. J.
    Rashtian, M.
    Banker, R.
    Reddy, V.
    Exner, D.
    Sperzel, J.
    Knops, R.
    EUROPEAN HEART JOURNAL, 2018, 39 : 828 - 829
  • [46] Feasibility study of the MRI compatibility of a Leadless Pacemaker System
    Blessberger, H.
    Kammler, J.
    Lichtenauer, M.
    Kiblboeck, D.
    Reiter, C.
    Schmit, P.
    Lambert, T.
    Kellermair, J.
    Fellner, F.
    Kypta, A.
    Steinwender, C.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 53 - 53
  • [47] A MODEL OF THE INFECTED CARDIAC-PACEMAKER
    PENN, RL
    FOWLER, M
    HANLEY, HG
    TUCKER, W
    JONES, MR
    HAMRIC, B
    GRANT, P
    CLINICAL RESEARCH, 1982, 30 (02): : A376 - A376
  • [48] Ultra-Compact Implantable Antenna With Enhanced Performance for Leadless Cardiac Pacemaker System
    Zada, Muhammad
    Shah, Izaz Ali
    Basir, Abdul
    Yoo, Hyoungsuk
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2021, 69 (02) : 1152 - 1157
  • [49] ARRHYTHMIAS AFTER ATRIAL AND DUAL-CHAMBER PACEMAKER IMPLANTATIONS
    JORDAENS, L
    ROBBENS, E
    VANWASSENHOVE, E
    CLEMENT, DL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 693 - 693
  • [50] Late cardiac tamponade after a helix-based active fixation leadless pacemaker implantation
    Chatani, Ryuki
    Tasaka, Hiroshi
    Yoshida, Kenta
    Yoshino, Mitsuru
    Kadota, Kazushige