Determination of the specific oxygen uptake rate in microorganisms including electrode time response

被引:0
|
作者
Torres Lopez, Ana Maria [1 ]
Quintero Diaz, Juan Carlos [2 ]
Atehortua Garces, Lucia [3 ]
机构
[1] Univ Antioquia, Programa Bioingn, Medellin 1226, Colombia
[2] Univ Antioquia, Dept Ingn Quim, Grp Bioproc, Medellin 1226, Colombia
[3] Univ Antioquia, Inst Biol, Grp Biotecnol Vegetal, Medellin 1226, Colombia
关键词
specific oxygen transfer rate; oxygen electrode; time response; Ganoderma lucidum;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The oxygen transfer rate is an important parameter for the aerobic fermentative process. By establishing the real oxygen uptake rate of the target organism we can determine the energetic and process requirements for aeration and agitation. We report in this paper the mathematical and methodological procedure for the determination of the specific oxygen uptake rate (QO(2)), taking the oxygen electrode response into account. This methodology was applied to the QO(2) determination for the Ganoderma lucidum medicinal mushroom while it was being cultured in a stirred reactor in the laboratory. The average value for QO(2) was 0.345 mmol O-2 (g biomass.h)(-1) +/- 0.0171 without taking the electrode time response into account and 0.383 mmol O-2 (g biomass.h)(-1) +/- 0.025 taking the electrode time response into account. Higher response times of the oxygen electrode resulted in a greater differences between the two QO(2) values obtained.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 50 条
  • [21] Determination of the velocity associated with the longest time to exhaustion at maximal oxygen uptake
    Billat, VL
    Blondel, N
    Berthoin, S
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1999, 80 (02) : 159 - 161
  • [22] DETERMINATION OF OXYGEN EMISSION AND UPTAKE IN LEAVES BY PULSED, TIME RESOLVED PHOTOACOUSTICS
    MAUZERALL, DC
    PLANT PHYSIOLOGY, 1990, 94 (01) : 278 - 283
  • [23] METHOD FOR ESTIMATING THE TOXICITY OF CHEMICALS TO ACTIVATED-SLUDGE .2. A RAPID-DETERMINATION AND APPLICATION OF OXYGEN-UPTAKE RATE BY USING OXYGEN-ELECTRODE
    MIHARA, Y
    FURUSAWA, N
    AKIBA, M
    IKEDA, S
    SAITO, K
    SHIROTO, N
    YOKOTA, K
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1991, 37 (03): : 179 - 184
  • [24] HEART-RATE AND OXYGEN-UPTAKE RESPONSE TO PERFORMANCE OF KARATE KATA
    SHAW, DK
    DEUTSCH, DT
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 1982, 22 (04): : 461 - 468
  • [26] Analysis of the Heart Rate and Oxygen Uptake Time Responses During Maximal Exercise
    Marques-Neto, Silvio R.
    Lopes, Thiago C.
    Laks, Daniel M.
    Neves, Carlos E. B.
    Santos, Edil L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S114 - S114
  • [27] An oxygen-specific optical "electrode" (optrode) directly measures oxygen uptake and reveals its dynamics at ocular surface
    Ma, Li
    Ferreira, Fernando
    Reid, Brian
    Zhao, Min
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [28] Determination of specific oxygen uptake rates in human hematopoietic cultures and implications for bioreactor design
    Peng, CA
    Palsson, BO
    ANNALS OF BIOMEDICAL ENGINEERING, 1996, 24 (03) : 373 - 381
  • [29] Use of specific ATP concentration and specific oxygen uptake rate to determine parameters of a structured model of biomass growth
    Gikas, P
    Livingston, AG
    ENZYME AND MICROBIAL TECHNOLOGY, 1998, 22 (06) : 500 - 510
  • [30] Determination of growth rate of microorganisms in broth from oxygen-sensitive fluorescence plate reader measurements
    Stitt, DT
    Nagar, MS
    Haq, TA
    Timmins, MR
    BIOTECHNIQUES, 2002, 32 (03) : 684 - +