Combination of computer-aided detection algorithms for automatic lung nodule identification

被引:42
|
作者
Camarlinghi, Niccolo [1 ,2 ]
Gori, Ilaria [3 ]
Retico, Alessandra [2 ]
Bellotti, Roberto [4 ,5 ,6 ]
Bosco, Paolo [7 ,8 ]
Cerello, Piergiorgio [9 ]
Gargano, Gianfranco [4 ,5 ]
Lopez Torres, Ernesto [10 ]
Megna, Rosario [4 ,5 ]
Peccarisi, Marco [11 ,12 ]
Fantacci, Maria Evelina [1 ,2 ]
机构
[1] Univ Pisa, Dipartimento Fis, Pisa, Italy
[2] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[3] Bracco Imaging SpA, Milan, Italy
[4] Univ Bari, Dipartimento Interateneo Fis M Merlin, Bari, Italy
[5] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
[6] Ctr Innovat Technol Signal Detect & Proc TIRES, Bari, Italy
[7] Univ Genoa, Dipartimento Fis, Genoa, Italy
[8] Ist Nazl Fis Nucl, Sez Genova, I-16146 Genoa, Italy
[9] Ist Nazl Fis Nucl, Sez Torino, I-10125 Turin, Italy
[10] CEADEN, Havana, Cuba
[11] Univ Salento, Dipartimento Fis, Lecce, Italy
[12] Ist Nazl Fis Nucl, Sez Lecce, I-73100 Lecce, Italy
关键词
Computer-aided detection; Computed tomography; Lung cancer; Medical image analysis; Pattern recognition; PULMONARY NODULES; CAD; CT;
D O I
10.1007/s11548-011-0637-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this work is to evaluate the potential of combining different computer-aided detection (CADe) methods to increase the actual support for radiologists of automated systems in the identification of pulmonary nodules in CT scans. The outputs of three different CADe systems developed by researchers of the Italian MAGIC-5 collaboration were combined. The systems are: the CAMCADe (based on a Channeler-Ant-Model which segments vessel tree and nodule candidates and a neural classifier), the RGVPCADe (a Region-Growing- Volume-Plateau algorithm detects nodule candidates and a neural network reduces false positives); the VBNACADe (two dedicated procedures, based respectively on a 3D dot-enhancement algorithm and on intersections of pleura surface normals, identifies internal and juxtapleural nodules, and a Voxel-Based-Neural-Approach reduces false positives. A dedicated OsiriX plugin implemented with the Cocoa environments of MacOSX allows annotating nodules and visualizing singles and combined CADe findings. The combined CADe has been tested on thin slice (lower than 2 mm) CTs of the LIDC public research database and the results have been compared with those obtained by the single systems. The FROC (Free Receiver Operating Characteristic) curves show better results than the best of the single approaches. Has been demonstrated that the combination of different approaches offers better results than each single CADe system. A clinical validation of the combined CADe as second reader is being addressed by means of the dedicated OsiriX plugin.
引用
收藏
页码:455 / 464
页数:10
相关论文
共 50 条
  • [31] Computer-Aided Detection of Lung Cancer: Combining Pulmonary Nodule Detection Systems with a Tumor Risk Prediction Model
    Seito, Arnaud A. A.
    Jacobs, Colin
    Ciompi, Francesco
    van Riel, Sarah J.
    Wille, Mathilde Marie Winker
    Dirksen, Asger
    van Rikxoort, Eva M.
    van Ginneken, Bram
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [32] Computer-aided detection of pulmonary nodules:: influence of nodule characteristics on detection performance
    Marten, K
    Engelke, C
    Seyfarth, T
    Grillhösl, A
    Obenauer, S
    Rummeny, EJ
    CLINICAL RADIOLOGY, 2005, 60 (02) : 196 - 206
  • [33] Overview of Computer Aided Detection and Computer Aided Diagnosis Systems for Lung Nodule Detection in Computed Tomography
    Ziyad, Shabana Rasheed
    Radha, Venkatachalam
    Vayyapuri, Thavavel
    CURRENT MEDICAL IMAGING, 2020, 16 (01) : 16 - 26
  • [34] Nodule border detection algorithm in digital mammograms for computer-aided diagnosis
    Vilarrasa, A
    Manrique, D
    Porras, J
    Ríos, J
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 1015 - 1015
  • [35] Lung nodule detection on thoracic computed tomography images: Preliminary evaluation of a computer-aided diagnosis system
    Gurcan, MN
    Sahiner, B
    Petrick, N
    Chan, HP
    Kazerooni, EA
    Cascade, PN
    Hadjiiski, L
    MEDICAL PHYSICS, 2002, 29 (11) : 2552 - 2558
  • [36] Computer-aided automatic polarimeter
    Kiezun, A
    Jaroszewicz, LR
    Swillo, R
    POLARIMETRY AND ELLIPSOMETRY, 1997, 3094 : 100 - 104
  • [37] Optimal matrix size of chest radiographs for computer-aided detection on lung nodule or mass with deep learning
    Young-Gon Kim
    Sang Min Lee
    Kyung Hee Lee
    Ryoungwoo Jang
    Joon Beom Seo
    Namkug Kim
    European Radiology, 2020, 30 : 4943 - 4951
  • [38] COMPUTER-AIDED AUTOMATIC DESIGN
    BONA, C
    GALLETTI, C
    LUCIFREDI, A
    MECHANISM AND MACHINE THEORY, 1973, 8 (04) : 437 - 456
  • [39] Optimal matrix size of chest radiographs for computer-aided detection on lung nodule or mass with deep learning
    Kim, Young-Gon
    Lee, Sang Min
    Lee, Kyung Hee
    Jang, Ryoungwoo
    Seo, Joon Beom
    Kim, Namkug
    EUROPEAN RADIOLOGY, 2020, 30 (09) : 4943 - 4951
  • [40] Performance and reading time of lung nodule identification on multidetector CT with or without an artificial intelligence-powered computer-aided detection system
    Hsu, H-H
    Ko, K-H
    Chou, Y-C
    Wu, Y-C
    Chiu, S-H
    Chang, C-K
    Chang, W-C
    CLINICAL RADIOLOGY, 2021, 76 (08) : 626.e23 - 626.e32