Left Ventricular Untwisting Is an Important Determinant of Early Diastolic Function

被引:124
作者
Burns, Andrew T. [1 ]
La Gerche, Andre [1 ]
Prior, David L. [1 ,2 ]
MacIsaac, Andrew I. [1 ,2 ]
机构
[1] Cardiac Invest Unit, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Med, St Vincents Hosp, Melbourne, Vic, Australia
关键词
diastole; echocardiography; speckle tracking imaging; torsion; untwisting; INTRAVENTRICULAR PRESSURE-GRADIENTS; SPECKLE TRACKING ECHOCARDIOGRAPHY; SOCIETY-OF-CARDIOLOGY; TIME CONSTANT TAU; HEART-FAILURE; DOPPLER-ECHOCARDIOGRAPHY; ELASTIC RECOIL; 2-DIMENSIONAL STRAIN; EJECTION FRACTION; RELAXATION;
D O I
10.1016/j.jcmg.2009.01.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to establish the relationship between invasive measures of diastolic function and untwisting parameters measured with speckle tracking imaging. BACKGROUND Left ventricular (LV) diastolic function is determined by early diastolic relaxation ( which creates suction gradients for LV filling) and myocardial stiffness. Assessment of LV torsion has shown that untwisting begins before aortic valve closure and, in animals, might be an important component of normal diastolic filling. Studies in human subjects using indirect indexes derived from right heart catheterization have suggested a relationship between tau and measures of untwisting, but the relationship between directly measured diastolic function indexes with micromanometer catheters and untwisting parameters has not been established in human subjects. METHODS Simultaneous Millar micromanometer LV pressure and echocardiographic assessment was performed on 18 patients (10 male, mean age 66 years) with normal systolic function and a spectrum of diastolic function. Invasive rate of the rise of LV pressure, dp/dt minimum and tau were recorded as measures of active relaxation, and the LV minimum diastolic pressure was recorded as an index of diastolic suction. The LV stiffness constant and functional chamber stiffness were estimated from hybrid pressure-volume loops. Echocardiographic speckle tracking imaging was used to quantify torsion. RESULTS As relaxation was impaired, (prolonged tau) untwisting was delayed (r = 0.35, p < 0.01). There were nonsignificant associations between reduced untwisting and longer values of tau and lower dp/dt minimum. Reduction in the extent of untwisting before mitral valve opening was associated with increased LV minimum diastolic pressure (r = -0.30, p < 0.034). No relation was observed between the LV stiffness constant (beta: r = 0.11, p = NS) or the functional LV chamber stiffness (b: r = 0.11, p = NS) and untwisting. CONCLUSIONS Untwisting parameters are related to invasive indexes of LV relaxation and suction but not to LV stiffness. These data suggest that untwisting is an important component of early diastolic LV filling but not later diastolic events. (J Am Coll Cardiol Img 2009; 2:709-16) (C) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:709 / 716
页数:8
相关论文
共 45 条
[11]   TRANSMITRAL PRESSURE-FLOW VELOCITY RELATION - IMPORTANCE OF REGIONAL PRESSURE-GRADIENTS IN THE LEFT-VENTRICLE DURING DIASTOLE [J].
COURTOIS, M ;
KOVACS, SJ ;
LUDBROOK, PA .
CIRCULATION, 1988, 78 (03) :661-671
[12]   MRI assessment of LV relaxation by untwisting rate:: a new isovolumic phase measure of τ [J].
Dong, SJ ;
Hees, PS ;
Siu, CO ;
Weiss, JL ;
Shapiro, EP .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 281 (05) :H2002-H2009
[13]  
Firstenberg MS, 2001, CIRCULATION, V104, pI330
[14]   New Doppler echocardiographic applications for the study of diastolic function [J].
Garcia, MJ ;
Thomas, JD ;
Klein, AL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (04) :865-875
[15]   Estimation of left ventricular operating stiffness from Doppler early filling deceleration time in humans [J].
Garcia, MJ ;
Firstenberg, MS ;
Greenberg, NL ;
Smedira, N ;
Rodriguez, L ;
Prior, D ;
Thomas, JD .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (02) :H554-H561
[16]   New noninvasive method for assessment of left ventricular rotation - Speckle tracking echocardiography [J].
Helle-Valle, T ;
Crosby, J ;
Edvardsen, T ;
Lyseggen, E ;
Amundsen, BH ;
Smith, HJ ;
Rosen, BD ;
Lima, JAC ;
Torp, H ;
Ihlen, H ;
Smiseth, OA .
CIRCULATION, 2005, 112 (20) :3149-3156
[17]   Titin determines the Frank-Starling relation in early diastole [J].
Helmes, M ;
Lim, CC ;
Liao, RL ;
Bharti, A ;
Cui, L ;
Sawyer, DB .
JOURNAL OF GENERAL PHYSIOLOGY, 2003, 121 (02) :97-110
[18]   Titin develops restoring force in rat cardiac myocytes [J].
Helmes, M ;
Trombitas, K ;
Granzier, H .
CIRCULATION RESEARCH, 1996, 79 (03) :619-626
[19]   RELATION BETWEEN LONGITUDINAL, CIRCUMFERENTIAL, AND OBLIQUE SHORTENING AND TORSIONAL DEFORMATION IN THE LEFT-VENTRICLE OF THE TRANSPLANTED HUMAN-HEART [J].
INGELS, NB ;
HANSEN, DE ;
DAUGHTERS, GT ;
STINSON, EB ;
ALDERMAN, EL ;
MILLER, DC .
CIRCULATION RESEARCH, 1989, 64 (05) :915-927
[20]   Utility of Doppler echocardiography and tissue Doppler imaging in the estimation of diastolic function in heart failure with normal ejection fraction -: A comparative Doppler-conductance catheterization study [J].
Kasner, Mario ;
Westermann, Dirk ;
Steendijk, Paul ;
Gaub, Regina ;
Wilkenshoff, Ursula ;
Weitmann, Kerstin ;
Hoffmann, Wolfgang ;
Poller, Wolfgang ;
Schultheiss, Heinz-Peter ;
Pauschinger, Matthias ;
Tschope, Carsten .
CIRCULATION, 2007, 116 (06) :637-647