Validation of intensity modulation on a commercial treatment planning system

被引:6
|
作者
Martin, E
Hachem, A
Marcié, S
Hérault, J
Costa, A
Bensadoun, RJ
Lagrange, JL
机构
[1] Univ Nice, LPES CRESA, Fac Sci, F-06108 Nice 2, France
[2] Ctr Antoine Lacassagne, F-06189 Nice, France
关键词
D O I
10.1118/1.1568981
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For two years now, a study on intensity modulated radiotherapy (IMRT) has been in progress at the Antoine Lacassagne Hospital Center for Cancer Therapy (in Nice) in collaboration with the University of Nice-Sophia Antipolis. The kind of intensity modulation that was used is the "step and shoot" technique in which the modulated beam is created both by adding and joining elementary fields. Before carrying out clinical tests, several problems regarding the production of modulated beams has to be mastered. The current developments of our study enable us to dosimetrically produce (in water phantom and in the PMMA phantom) complex modulated whose segmentation was calculated by one commercial treatment planning system (TPS). Nevertheless, we showed and studied some critical discrepancies between standard clinical calculations and the calculations using field segmentation. We showed that with nonoptimal conditions of segmentation the discrepancies, which are due to the type of algorithm used, could bring about significant errors inside the field of up to 10% of maximum dose. Another point of our study is the quantification and resolution of differences between measurements and calculations due to the internal segmentation of calculated modulated fields and their realization on Linac. Once again, in none optimal conditions of segmentation and inside the field we obtained discrepancies up to 20% of maximum dose between calculations using field segmentation and measurements. That was mainly due to the tongue and groove effect and penumbra phenomena. This study allows us to show that the discrepancies between segmentation calculations and standard clinical calculations should be solved by the use of penumbra models during segmentation calculations. We will introduce both the study and its near-future perspectives. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:925 / 936
页数:12
相关论文
共 50 条
  • [21] Improvements of a commercial treatment planning system on the MLC field
    Chow, J.
    Grigorov, G.
    Jiang, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 2110 - 2110
  • [22] Dosimetric validation of a commercial Monte Carlo based IMRT planning system
    Grofsmid, Dennis
    Dirkx, Maarten
    Marijnissen, Hans
    Woudstra, Evert
    Heijmen, Ben
    MEDICAL PHYSICS, 2010, 37 (02) : 540 - 549
  • [23] Influence of ionization chamber size for intensity modulation treatment planning modeling
    Venencia, C
    Besa, P
    Somarriba, F
    MEDICAL PHYSICS, 2005, 32 (06) : 1985 - 1985
  • [24] Commissioning and Validation of the First Monte Carlo Based Dose Calculation Algorithm Commercial Treatment Planning System in Mexico
    Larraga-Gutierrez, J. M.
    Garcia-Garduno, O. A.
    Galvan de la Cruz, O. O.
    Hernandez-Bojorquez, M.
    Ballesteros-Zebadua, P.
    ELEVENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2010, 1310 : 90 - +
  • [25] Commercial vs In-House Developed Intensity-Modulated Proton Therapy Treatment Planning System for Advanced Stage Lung Cancer: A Treatment Planning Comparison
    Liu, C.
    Sio, T.
    Shan, J.
    Schild, S.
    Daniels, T.
    DeWees, T.
    Hu, Y.
    Ding, X.
    Bues, M.
    Liu, W.
    MEDICAL PHYSICS, 2019, 46 (06) : E596 - E596
  • [26] Clinical modeling and validation of breast tissue expander metallic ports in a commercial treatment planning system for proton therapy
    Kang, Yixiu
    Shen, Jiajian
    Bues, Martin
    Hu, Yanle
    Liu, Wei
    Ding, Xiaoning
    MEDICAL PHYSICS, 2021, 48 (11) : 7512 - 7525
  • [27] A VMAT planning solution for prostate patients using a commercial treatment planning system
    Boylan, C. J.
    Golby, C.
    Rowbottom, C. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (14): : N395 - N404
  • [28] Anthropomorphic phantom measurements for the validation of a treatment planning system
    Dunscombe, P
    McGhee, P
    Lederer, E
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03): : 399 - 411
  • [29] Evaluation of An Automated Treatment Planning Verification System for Intensity-Modulated Radiotherapy Treatment Planning
    Xiao, L.
    Yin, Y.
    Tong, L. Xiu
    MEDICAL PHYSICS, 2017, 44 (06) : 2897 - 2897
  • [30] DOSIMETRIC VALIDATION OF A COMMERCIAL VMAT PLANNING SYSTEM: ABSOLUTE DOSE AND OUTPUT FACTORS
    Clemente Gutierrez, F.
    Ramirez Ros, J. C.
    De la Casa de Julian, M. A.
    Cabello Murillo, E.
    Martin De Miguel, M.
    Perez Vara, C.
    Prieto Villacorta, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S534 - S534