Validation of intensity modulation on a commercial treatment planning system

被引:6
|
作者
Martin, E
Hachem, A
Marcié, S
Hérault, J
Costa, A
Bensadoun, RJ
Lagrange, JL
机构
[1] Univ Nice, LPES CRESA, Fac Sci, F-06108 Nice 2, France
[2] Ctr Antoine Lacassagne, F-06189 Nice, France
关键词
D O I
10.1118/1.1568981
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For two years now, a study on intensity modulated radiotherapy (IMRT) has been in progress at the Antoine Lacassagne Hospital Center for Cancer Therapy (in Nice) in collaboration with the University of Nice-Sophia Antipolis. The kind of intensity modulation that was used is the "step and shoot" technique in which the modulated beam is created both by adding and joining elementary fields. Before carrying out clinical tests, several problems regarding the production of modulated beams has to be mastered. The current developments of our study enable us to dosimetrically produce (in water phantom and in the PMMA phantom) complex modulated whose segmentation was calculated by one commercial treatment planning system (TPS). Nevertheless, we showed and studied some critical discrepancies between standard clinical calculations and the calculations using field segmentation. We showed that with nonoptimal conditions of segmentation the discrepancies, which are due to the type of algorithm used, could bring about significant errors inside the field of up to 10% of maximum dose. Another point of our study is the quantification and resolution of differences between measurements and calculations due to the internal segmentation of calculated modulated fields and their realization on Linac. Once again, in none optimal conditions of segmentation and inside the field we obtained discrepancies up to 20% of maximum dose between calculations using field segmentation and measurements. That was mainly due to the tongue and groove effect and penumbra phenomena. This study allows us to show that the discrepancies between segmentation calculations and standard clinical calculations should be solved by the use of penumbra models during segmentation calculations. We will introduce both the study and its near-future perspectives. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:925 / 936
页数:12
相关论文
共 50 条
  • [1] TOWARDS THE VALIDATION OF A COMMERCIAL HYPERTHERMIA TREATMENT PLANNING SYSTEM
    Li, Zhen
    Maccarini, P. F.
    Arabe, O. A.
    Stakhursky, V.
    Joines, W. T.
    Stauffer, P. R.
    Vogel, M.
    Crawford, D.
    MICROWAVE JOURNAL, 2008, 51 (12) : 28 - +
  • [2] Towards the validation of a commercial hyperthermia treatment planning system
    Duke University, Durham, NC, United States
    不详
    Microwave J, 2008, 12 (28-42):
  • [3] Commissioning and testing of a commercial intensity modulated treatment planning system
    Kuchnir, FT
    Reft, CS
    Johnson, LS
    Kung, JH
    Pelizzari, CA
    Roeske, JC
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1184 - 1186
  • [4] Comparative analysis of intensity modulation inverse planning modules of three commercial treatment planning systems
    Fogliato, A
    Bolsi, A
    Cozzi, L
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 120 - 120
  • [5] Validation of physics improvements for IMRT with a commercial treatment-planning system
    Cadman, Patrick
    McNutt, Todd
    Bzdusek, Karl
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (02): : 74 - 86
  • [6] Dosimetric considerations for validation of a sequential IMRT process with a commercial treatment planning system
    Cadman, P
    Bassalow, R
    Sidhu, NPS
    Ibbott, G
    Nelson, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16): : 3001 - 3010
  • [7] Commissioning and Initial Validation of Commercial Treatment Planning System for the Electron FLASH Research Extension
    Oh, K.
    Gallagher, K. J.
    Schott, D.
    Wisnoskie, S. B.
    Lei, Y.
    Hendley, S.
    Wang, S.
    Graff, B.
    Jenkins, C.
    Hyun, M.
    Granatowicz, A.
    Schmidt, M.
    Smith, W.
    McNeur, J.
    Baine, M.
    Enke, C. A.
    Yan, Y.
    Zhou, S. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E702 - E703
  • [8] Validation of a deformable image registration produced by a commercial treatment planning system in head and neck
    Garcia-Molla, Rafael
    de Marco-Blancas, Noelia
    Bonaque, Jorge
    Vidueira, Laura
    Lopez-Tarjuelo, Juan
    Perez-Calatayud, Jose
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (03): : 219 - 223
  • [9] NEUTRON THERAPY TREATMENT PLANNING WITH A MODIFIED COMMERCIAL TREATMENT PLANNING SYSTEM
    KNESCHAUREK, P
    SCHRAUBE, H
    STRAHLENTHERAPIE, 1984, 160 (02) : 118 - 119
  • [10] Comparative analysis of intensity modulation inverse planning modules of three commercial treatment planning systems applied to head and neck tumour model
    Fogliata, A
    Bolsi, A
    Cozzi, L
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) : 29 - 40