Regional deconvolution method for partial volume correction in brain PET

被引:0
|
作者
Rusinek, H [1 ]
Tsuia, WH [1 ]
de Leon, MJ [1 ]
机构
[1] Bellevue Hosp Ctr, Dept Radiol, New York, NY 10016 USA
关键词
functional imaging; brain metabolism; MRI; PET; partial volume correction;
D O I
10.1117/12.428166
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Correction of PET images for partial volume effects (PVE) is of particular utility in studies of metabolism in brain aging and brain disorders, PVE is commonly corrected using voxel-by-voxel factors obtained from a high resolution brain mask (obtained from the coregistered MR scan), after convolution with the point spread function (PSF) of the imaging system. In a recently proposed regional deconvolution (RD) method, the observed regional activity is expressed as linear combinations of the true metabolic activity. The weights are obtained by integrating the PSF over the geometric extent of the brain regions. We have analyzed the accuracy of RD and two other PVE correction algorithms under a variety of conditions using simulated PET scans. Each of the brain regions was assigned a distribution of metabolic activity, with gray matter/white matter contrast representative of subjects in several age categories. Simulations were performed over a wide range of PET resolutions. The influence of PET/MR misregistration and heterogeneity of brain metabolism were also evaluated. Our results demonstrate the importance of correcting PET metabolic images for PVE. Without such correction, the regional brain activity values are contaminated with 30-40% errors. Under most conditions studied, the accuracy of RD and of the three-compartmental method were superior to the accuracy of the two-compartmental method. Our study provides the first demonstration of the feasibility of RD algorithm to provide accurate correction for a large number (n=109) of brain compartments. PVE correction methods appear to be promising tools in studies of metabolism in normal brain, brain aging, and brain disorders.
引用
收藏
页码:409 / 418
页数:10
相关论文
共 50 条
  • [41] A simple correction method for the partial volume effect in Discovery STE PET/CT
    Mitsumoto, Tatsuya
    Mizoguchi, Noriko
    Himuro, Kazuhiko
    Sakaguchi, Yuichi
    Kaneko, Koichiro
    Onizuka, Yoshihiko
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [42] Post-reconstruction Partial Volume Correction of PET images using iterative deconvolution algorithm and anatomical priors
    D'Ambrosio, D.
    Marengo, M.
    Boschi, S.
    Fanti, S.
    Spinelli, A. E.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 257 - 260
  • [43] Partial Volume Effect Correction in PET Using Regularized Iterative Deconvolution with Variance Control Based On Local Topology
    Kirov, A. S.
    Piao, J. Z.
    Schmidtlein, C. Ross
    MEDICAL PHYSICS, 2008, 35 (06)
  • [44] Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology
    Kirov, A. S.
    Piao, J. Z.
    Schmidtlein, C. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10): : 2577 - 2591
  • [45] Autoradiographic brain phantom for the evaluation of partial-volume correction in PET and SPECT.
    Dougherty, DA
    Hsiao, IT
    Wang, W
    Gindi, GR
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 121P - 122P
  • [46] Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET
    Baete, K
    Nuyts, J
    Van Laere, K
    Van Paesschen, W
    Ceyssens, S
    De Ceuninck, L
    Gheysens, O
    Kelles, A
    Van den Eynden, J
    Suetens, P
    Dupont, P
    NEUROIMAGE, 2004, 23 (01) : 305 - 317
  • [47] Partial Volume Correction in PET Images: A Single Correction Method Applied for Multiple Source to Background Ratios
    Piper, J.
    Shen, G.
    Nelson, A. D.
    Nelson, A. S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [48] A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction
    Merlin, Thibaut
    Visvikis, Dimitris
    Fernandez, Philippe
    Lamare, Frederic
    MEDICAL PHYSICS, 2015, 42 (02) : 804 - 819
  • [49] Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging
    Boussion, N.
    Le Rest, C. Cheze
    Hatt, M.
    Visvikis, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (07) : 1064 - 1075
  • [50] A novel partial volume effects correction technique integrating deconvolution associated with denoising within the PET image reconstruction process
    Merlin, T.
    Le Pogam, A.
    Fernandez, P.
    Visvikis, D.
    Lamare, F.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2429 - 2432