Multiparametric prostate MRI quality assessment using a semi-automated PI-QUAL software program

被引:20
|
作者
Giganti, Francesco [1 ,2 ]
Lindner, Sydney [3 ]
Piper, Jonathan W. [3 ]
Kasivisvanathan, Veeru [2 ,4 ]
Emberton, Mark [4 ]
Moore, Caroline M. [2 ,4 ]
Allen, Clare [1 ]
机构
[1] Univ Coll London Hosp NHS Fdn Trust, Dept Radiol, London, England
[2] UCL, Div Surg & Intervent Sci, 3rd Floor,Charles Bell House,43-45 Foley St, London W1W 7TS, England
[3] MIM Software Inc, Cleveland, OH USA
[4] Univ Coll London Hosp NHS Fdn Trust, Dept Urol, London, England
关键词
Prostatic neoplasms; Multiparametric magnetic resonance imaging; Quality improvements; Software;
D O I
10.1186/s41747-021-00245-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The technical requirements for the acquisition of multiparametric magnetic resonance imaging (mpMRI) of the prostate have been clearly outlined in the Prostate Imaging Reporting and Data System (PI-RADS) guidelines, but there is still huge variability in image quality among centres across the world. It has been difficult to quantify what constitutes a good-quality image, and a first attempt to address this matter has been the publication of the Prostate Imaging Quality (PI-QUAL) score and its dedicated scoring sheet. This score includes the assessment of technical parameters that can be obtained from the DICOM files along with a visual evaluation of certain features on prostate MRI (e.g., anatomical structures). We retrospectively analysed the image quality of 10 scans from different vendors and magnets using a semiautomated dedicated PI-QUAL software program and compared the time needed for assessing image quality using two methods (semiautomated assessment versus manual filling of the scoring sheet). This semiautomated software is able to assess the technical parameters automatically, but the visual assessment is still performed by the radiologist. There was a significant reduction in the reporting time of prostate mpMRI quality according to PI-QUAL using the dedicated software program compared to manual filling (5 ' 54 '' versus 7 ' 59 ''; p = 0.005). A semiautomated PI-QUAL software program allows the radiologist to assess the technical details related to the image quality of prostate mpMRI in a quick and reliable manner, allowing clinicians to have more confidence that the quality of mpMRI of the prostate is sufficient to determine patient care.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] PI-QUAL-DOES PROSTATE MRI QUALITY IMPACT NEGATIVE PREDICTIVE VALUE FOR "NEGATIVE" PROSTATE MRI SCANS?
    Jason, Scovell
    Zaila, Ardines Kassandra
    Ross, Liao
    Kailash, Singh
    Robert, Abouassaly
    Christopher, Weight
    Andrei, Purysko
    Ryan, Ward
    Zeyad, Schwen
    UROLOGIC ONCOLOGY-SEMINARS AND ORIGINAL INVESTIGATIONS, 2025, 43 (03)
  • [42] Role of the Prostate Imaging Quality PI-QUAL Score for Prostate Magnetic Resonance Image Quality in Pathological Upstaging After Radical Prostatectomy: A Multicentre European Study
    Windisch, Olivier
    Benamran, Daniel
    Dariane, Charles
    Favre, Martina Martins
    Djouhri, Mehdi
    Chevalier, Maxime
    Guillaume, Benedicte
    Oderda, Marco
    Gatti, Marco
    Faletti, Riccardo
    Colinet, Valentin
    Lefebvre, Yolene
    Bodard, Sylvain
    Diamand, Romain
    Fiard, Gaelle
    EUROPEAN UROLOGY OPEN SCIENCE, 2023, 47 : 94 - 101
  • [43] Why quality matters in prostate-MR images: implementing PI-QUAL v2 for improved diagnosis and research
    Barentsz, Jelle
    Thijssen, Linda
    Moore, Caroline
    de Rooij, Maarten
    EUROPEAN RADIOLOGY, 2025,
  • [44] Semi-automated brain tumor and edema segmentation using MRI
    Xie, K
    Yang, J
    Zhang, ZG
    Zhu, YM
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 56 (01) : 12 - 19
  • [45] Semi-Automated Assessment of Keratoconus using AS-OCT
    Lin, Anna
    Maripudi, Snehaa
    Mohammed, Isa S. K.
    Munir, Wuqaas M.
    Munir, Saleha Z.
    Alexander, Janet L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (11)
  • [46] Suitability of Semi-Automated Tumor Response Assessment of Liver Metastases using a Dedicated Software Package
    Kalkmann, J.
    Ladd, S. C.
    de Greiff, A.
    Forsting, M.
    Stattaus, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (07): : 581 - 588
  • [47] Prostate MR image quality of apparent diffusion coefficient maps versus fractional intracellular volume maps from VERDICT MRI using the PI-QUAL score and a dedicated Likert scale for artefacts
    Singh, Saurabh
    Giganti, Francesco
    Dickinson, Louise
    Rogers, Harriet
    Kanber, Baris
    Clemente, Joey
    Pye, Hayley
    Heavey, Susan
    Stopka-Farooqui, Urszula
    Johnston, Edward W.
    Moore, Caroline M.
    Freeman, Alex
    Whitaker, Hayley C.
    Alexander, Daniel C.
    Panagiotaki, Eleftheria
    Punwani, Shonit
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
  • [48] CHARACTERIZATION AUTOMATED AND SEMI-AUTOMATED ASSESSMENT OF THE QUALITY OF WRITTEN TEXTS: A SYSTEMATIC REVIEW
    Lillo-Fuentes, Fernando
    Venegas, Rene
    Lobos, Ignacio
    PERSPECTIVA EDUCACIONAL, 2023, 62 (02): : 5 - 36
  • [49] Semi-automated Software Requirements Categorisation using Machine Learning Algorithms
    Talele, Pratvina
    Apte, Siddharth
    Phalnikar, Rashmi
    Talele, Harsha
    INTERNATIONAL JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING SYSTEMS, 2023, 14 (10) : 1107 - 1114
  • [50] Measurement of the IMT using a semi-automated software (ThickSoft): A validation study
    Vernet, Anton
    Pallas, Honorio
    Masana, Lluis
    Coll, Blai
    COMPUTATIONAL VISION AND MEDICAL IMAGING PROCESSING, 2008, : 117 - +