Correlation between gamma index passing rate and clinical dosimetric difference for pre-treatment 2D and 3D volumetric modulated arc therapy dosimetric verification

被引:46
|
作者
Jin, X. [1 ]
Yan, H. [1 ]
Han, C. [1 ]
Zhou, Y. [1 ]
Yi, J. [1 ]
Xie, C. [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 1, Dept Radiotherapy & Chemotherapy, Wenzhou, Peoples R China
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1047期
关键词
QUALITY-ASSURANCE; PER-BEAM; IMRT; VMAT; QA; TOMOTHERAPY; PHANTOM; CANCER; BOOST;
D O I
10.1259/bjr.20140577
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate comparatively the percentage gamma passing rate (% GP) of two-dimensional (2D) and three-dimensional (3D) pre-treatment volumetric modulated arc therapy (VMAT) dosimetric verification and their correlation and sensitivity with percentage dosimetric errors (% DE). Methods: % GP of 2D and 3D pre-treatment VMAT quality assurance (QA) with different acceptance criteria was obtained by ArcCHECK (R) (Sun Nuclear Corporation, Melbourne, FL) for 20 patients with nasopharyngeal cancer (NPC) and 20 patients with oesophageal cancer. % DE were calculated from planned dose-volume histogram (DVH) and patients' predicted DVH calculated by 3DVH (R) software (Sun Nuclear Corporation). Correlation and sensitivity between % GP and % DE were investigated using Pearson's correlation coefficient (r) and receiver operating characteristics (ROCs). Results: Relatively higher % DE on some DVH-basedmetrics were observed for both patients with NPC and oesophageal cancer. Except for 2%/2mm criterion, the average % GPs for all patients undergoing VMAT were acceptablewith average rates of 97.11% +/- 1.54% and 97.39% +/- 1.37% for 2D and 3D 3%/3mm criteria, respectively. The number of correlations for 3D was higher than that for 2D (21 vs 8). However, the general correlation was still poor for all the analysed metrics (9 out of 26 for 3D 3%/3mm criterion). The average area under the curve (AUC) of ROCs was 0.66 +/- 0.12 and 0.71 +/- 0.21 for 2D and 3D evaluations, respectively. Conclusions: There is a lack of correlation between % GP and % DE for both 2D and 3D pre-treatment VMAT dosimetric evaluation. DVH-based dose metrics evaluation obtained from 3DVH will provide more useful analysis. Advances in knowledge: Correlation and sensitivity of % GP with % DE for VMAT QA were studied for the first time.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Commissioning and dosimetric verification of volumetric modulated arc therapy for multiple modalities using electronic portal imaging device-based 3D dosimetry system: a novel approach
    Hajare, Raghavendra
    Sreelakshmi, K. K.
    Kumar, Anil
    Kalita, Rituraj
    Kaginelli, Shanmukhappa
    Mahantshetty, Umesh
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 412 - 424
  • [32] A Correlation Study of 2D and 3D Gamma Passing Rates for Prostate IMRT Plans
    Zhang, D.
    Wang, B.
    Deng, X.
    Ma, C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3335 - 3335
  • [33] Pulse dose-rate brachytherapy and treatment of uterine cervix cancer:: impact of a 3D or a 2D dosimetric support
    Tournat, H.
    Chilles, A.
    Charra-Brunaud, C.
    Peiffert, D.
    Ahmad, F.
    Metayer, Y.
    CANCER RADIOTHERAPIE, 2007, 11 (04): : 188 - 196
  • [34] Comparative Dosimetric Study of 3D Conformal Radiotherapy versus Volumetric Modulated Arc Radiotherapy in Synchronous Bilateral Breast Cancer
    Gomaa, H. A. G. A.
    Almaghrabi, M. Y.
    Al-Gaoud, M. A. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E41 - E42
  • [35] TRUE 3D DOSIMETRY OF SINGLE ARC VOLUMETRIC MODULATED ARC THERAPY (VMAT) FOR THE TREATMENT OF PROSTATE
    Wai, P.
    Bedford, J.
    Doran, S.
    Warrington, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S218 - S219
  • [36] Dosimetric impact of inter-observer variability for 3D conformal radiotherapy and volumetric modulated arc therapy: the rectal tumor target definition case
    Francesca Lobefalo
    Mario Bignardi
    Giacomo Reggiori
    Angelo Tozzi
    Stefano Tomatis
    Filippo Alongi
    Antonella Fogliata
    Anna Gaudino
    Piera Navarria
    Luca Cozzi
    Marta Scorsetti
    Pietro Mancosu
    Radiation Oncology, 8
  • [37] Dosimetric impact of inter-observer variability for 3D conformal radiotherapy and volumetric modulated arc therapy: the rectal tumor target definition case
    Lobefalo, Francesca
    Bignardi, Mario
    Reggiori, Giacomo
    Tozzi, Angelo
    Tomatis, Stefano
    Alongi, Filippo
    Fogliata, Antonella
    Gaudino, Anna
    Navarria, Piera
    Cozzi, Luca
    Scorsetti, Marta
    Mancosu, Pietro
    RADIATION ONCOLOGY, 2013, 8
  • [38] Comparison of the Dosimetric Influence of Applicator Displacement on 2D and 3D Brachytherapy for Cervical Cancer Treatment
    Wu, Ailin
    Tang, Du
    Wu, Aidong
    Liu, Yunqin
    Qian, Liting
    Zhu, Lei
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [39] Predictive gamma passing rate of 3D detector array-based volumetric modulated arc therapy quality assurance for prostate cancer via deep learning
    Matsuura, Takaaki
    Kawahara, Daisuke
    Saito, Akito
    Miura, Hideharu
    Yamada, Kiyoshi
    Ozawa, Shuichi
    Nagata, Yasushi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (04) : 1073 - 1081
  • [40] Predictive gamma passing rate of 3D detector array-based volumetric modulated arc therapy quality assurance for prostate cancer via deep learning
    Takaaki Matsuura
    Daisuke Kawahara
    Akito Saito
    Hideharu Miura
    Kiyoshi Yamada
    Shuichi Ozawa
    Yasushi Nagata
    Physical and Engineering Sciences in Medicine, 2022, 45 : 1073 - 1081