Determination of Acidity in Donor Milk: Comparison of Results Obtained by 2 Different Analytical Methods

被引:6
|
作者
Escuder-Vieco, Diana [1 ,2 ]
Vazquez-Roman, Sara [1 ]
Sanchez-Pallas, Juan [3 ]
Ureta-Velasco, Noelia [1 ]
Mosqueda-Pena, Rocio [1 ]
Rosa Pallas-Alonso, Carmen [1 ,2 ]
机构
[1] Hosp 12 Octubre, Dept Neonatol, Edificio Maternoinfantil,Avda Cordoba S-N, E-28041 Madrid, Spain
[2] SAMID Network Spanish Collaborat Maternal & Child, RD12-0026-0007, Madrid, Spain
[3] Univ Autonoma Madrid, Environm Sci Degree, Madrid, Spain
关键词
breastfeeding; donor milk; human milk banking; quality control; acidity;
D O I
10.1177/0890334415591338
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background: There is no uniformity among milk banks on milk acceptance criteria. The acidity obtained by the Dornic titration technique is a widely used quality control in donor milk. However, there are no comparative data with other acidity-measuring techniques, such as the pH meter. Objective: The objective of this study was to assess the correlation between the Dornic technique and the pH measure to determine the pH cutoff corresponding to the Dornic degree limit value used as a reference for donor milk quality control. Methods: Fifty-two human milk samples were obtained from 48 donors. Acidity was measured using the Dornic method and pH meter in triplicate. Statistical data analysis to estimate significant correlations between variables was carried out. The Dornic acidity value that led to rejecting donor milk was >= 8 Dornic degrees (degrees D). Results: In the evaluated sample size, Dornic acidity measure and pH values showed a statistically significant negative correlation (tau = -0.780; P = .000). A pH value of 6.57 corresponds to 8 degrees D and of 7.12 to 4 degrees D. Conclusion: Donor milk with a pH over 6.57 may be accepted for subsequent processing in the milk bank. Moreover, the pH measurement seems to be more useful due to certain advantages over the Dornic method, such as objectivity, accuracy, standardization, the lack of chemical reagents required, and the fact that it does not destroy the milk sample.
引用
收藏
页码:NP73 / NP75
页数:3
相关论文
共 50 条
  • [31] SIMPLIFIED TECHNIQUES FOR ANTISTREPTOLYSIN ESTIMATION - COMPARISON OF RESULTS OBTAINED USING DIFFERENT METHODS
    BAURIAUD, R
    LEFEVRE, JC
    GALTIER, M
    LARENG, MB
    NOUVELLE PRESSE MEDICALE, 1976, 5 (36): : 2392 - 2393
  • [32] COMPARISON OF RESULTS OBTAINED WITH DIFFERENT METHODS FOR ESTIMATING GABA TURNOVER IN RAT NEOSTRIATUM
    PAULSEN, R
    FONNUM, F
    BIOCHEMICAL PHARMACOLOGY, 1987, 36 (09) : 1539 - 1544
  • [33] A COMPARISON OF RESULTS OBTAINED BY 2 DIFFERENT CHROMIUM-51 METHODS OF DETERMINING PLATELET SURVIVAL AND RECOVERY
    ROCK, G
    TITTLEY, P
    TRANSFUSION, 1990, 30 (05) : 407 - 410
  • [34] Comparison of analytical methods for determination of nutrient concentration in beef cow colostrum and milk.
    Rathert, Abigail R.
    Stephenson, Emma L.
    Kenny, Ann L.
    Meyer, Allison M.
    JOURNAL OF ANIMAL SCIENCE, 2019, 97 : 149 - 149
  • [35] DETERMINATION OF LACTOSE IN MILK - COMPARISON OF METHODS
    ESSIG, AM
    KLEYN, DH
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1983, 66 (06): : 1514 - 1516
  • [36] Testing the effects of processing on donor human Milk: Analytical methods
    Kontopodi, Eva
    Hettinga, Kasper
    Stahl, Bernd
    van Goudoever, Johannes B.
    van Elburg, Ruurd M.
    FOOD CHEMISTRY, 2022, 373
  • [37] COMPARISON OF METHODS FOR DETERMINATION OF SURFACE ACIDITY OF SOLID CATALYSTS
    FORNI, L
    CATALYSIS REVIEWS-SCIENCE AND ENGINEERING, 1973, 8 (01): : 65 - 115
  • [38] Comparison of serologic HLA class I results in a bone marrow donor registry with results obtained by DNA methods
    Chang, YW
    Hawkins, BR
    TRANSPLANTATION PROCEEDINGS, 1998, 30 (07) : 3486 - 3487
  • [39] Titratable Acidity in Kiwifruit, a Comparison of Different Methods of Analysis
    Marsh, K. B.
    Sullivan, M.
    Thorp, T. G.
    VII INTERNATIONAL SYMPOSIUM ON KIWIFRUIT, 2011, (913): : 657 - 660
  • [40] COMPARISON OF FACTORIAL STRUCTURES ON A BATTERY OF TEST OBTAINED BY 2 ANALYTICAL AND ROTATIONAL METHODS
    XUAN, AN
    TRAVAIL HUMAIN, 1963, 26 (3-4): : 283 - 295