Temperature monitoring in radiofrequency catheter ablation of atrial flutter using the linear ablation technique

被引:12
|
作者
Wen, ZC
Chen, SA
Tai, CT
Chiang, CE
Lee, SH
Chen, YJ
Yu, WC
Huang, JL
Chang, MS
机构
[1] VET GEN HOSP,DIV CARDIOL,TAIPEI,TAIWAN
[2] NATL YANG MING UNIV,SCH MED,DEPT MED,DIV CARDIOL,TAIPEI 112,TAIWAN
[3] SHIN KONG MEM HOSP,DEPT MED,TAIPEI,TAIWAN
[4] VET GEN HOSP,DEPT MED,DIV CARDIOL,TAICHUNG,TAIWAN
关键词
atrial flutter; temperature control; radiofrequency; catheter ablation;
D O I
10.1111/j.1540-8167.1996.tb00480.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Information about temperature and impedance monitoring during radiofrequency catheter linear ablation of atrial flutter has not been reported. We proposed that a radiofrequency catheter ablation system using a closed-loop temperature control model could decrease the incidence of coagulum formation and shorten the radiation exposure and procedure times compared with those found in a power control model. Methods and Results: Forty patients (8 women and 32 men; mean age 64 +/- 7 years) with atrial flutter were referred for radiofrequency ablation. The patients were randomized into two groups: group I patients underwent radiofrequency catheter linear ablation of atrial flutter using a power control of energy output model; and group II patients underwent the closed-loop temperature control model with a target electrode temperature of 70 degrees C. As compared with group II, group I patients had a higher incidence of coagulum formation (12% vs 2%, P < 0.05), temperature shutdown (11% vs 0%, P < 0.01), and impedance shutdown (16% vs 3%, P < 0.01), more radiofrequency applications (7 +/- 3 vs 4 +/- 2, P < 0.01), and longer procedure time (100 +/- 25 vs 75 +/- 23 minutes, P < 0.05) and radiation exposure time (31 +/- 10 vs 20 +/- 7 minutes, P < 0.05) required for successful ablation. Larger deviations of temperature (9.0 degrees +/- 2.4 degrees C vs 5.0 degrees +/- 1.2 degrees C, P < 0.0001) and impedance (9.2 +/- 2.6 Ohm vs 5.3 +/- 1.6 Ohm, P < 0.0001) were also found in group I patients compared with those in group II. Conclusions: This study demonstrated that a closed-loop temperature control model could facilitate the effects of radiofrequency catheter ablation of the atrial flutter circuit by decreasing coagulum formation, temperature and impedance shutdown, and procedure and radiation exposure times.
引用
收藏
页码:1050 / 1057
页数:8
相关论文
共 50 条
  • [21] Radiofrequency ablation of atrial flutter
    Schumacher, B
    Lewalter, T
    Wolpert, C
    Jung, W
    Lüderitz, B
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (08) : S139 - S145
  • [22] Feasibility of common atrial flutter radiofrequency catheter ablation in outpatients
    Marijon, E.
    Boveda, S.
    Combes, N.
    Bortone, A.
    Najjar, J.
    Donzeau, J. P.
    Jacob, S.
    Albenque, J. P.
    CIRCULATION, 2008, 118 (12) : E432 - E432
  • [23] RADIOFREQUENCY CATHETER ABLATION OF UNCOMMON TYPE ATRIAL-FLUTTER
    SATAKE, S
    OKISHIGE, K
    AZEGAMI, K
    SATO, T
    OHIRA, H
    YAMASHITA, K
    CIRCULATION, 1994, 90 (04) : 594 - 594
  • [24] Late recurrence of atrial flutter following radiofrequency catheter ablation
    Cheema, AN
    Grais, IM
    Burke, JH
    Inbar, S
    Kadish, AH
    Goldberger, JJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (12): : 2998 - 3001
  • [25] CATHETER ABLATION OF ATRIAL FLUTTER FOLLOWING RADIOFREQUENCY MAZE PROCEDURES
    Barbato, G.
    Carinci, V.
    Marinelli, G.
    Di Pasquale, G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 : S57 - S57
  • [26] Radiofrequency catheter ablation for pulmonary hypertension patients with atrial flutter
    Zhang, Aikai
    Ding, Lei
    Zhang, Hongda
    Mi, Lijie
    Yu, Fengyuan
    Tang, Min
    ESC HEART FAILURE, 2024, 11 (02): : 883 - 892
  • [27] Significance of double potentials in radiofrequency catheter ablation of atrial flutter
    Tada, H
    Oral, H
    Sticherling, C
    Chough, SP
    Baker, RL
    Wasmer, KA
    Kim, MH
    Pelosi, F
    Michaud, GF
    Knight, BP
    Strickberger, SA
    Morady, F
    CIRCULATION, 2000, 102 (18) : 573 - 573
  • [28] Radiofrequency catheter ablation of common atrial flutter in 200 patients
    Fischer, B
    Jais, P
    Shah, DP
    Chouairi, S
    Haissaguerre, M
    Garrigues, S
    Poquet, F
    Gencel, L
    Clementy, J
    Marcus, FI
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (12) : 1225 - 1233
  • [29] Catheter ablation of atrial flutter
    Kottkamp, H
    Hindricks, G
    THORACIC AND CARDIOVASCULAR SURGEON, 1999, 47 : 357 - 361
  • [30] Left atrial flutter after radiofrequency catheter ablation of focal atrial fibrillation
    Villacastín, J
    Pérez-Castellano, N
    Moreno, J
    González, R
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (04) : 417 - 421