Temperature monitoring in radiofrequency catheter ablation of atrial flutter using the linear ablation technique

被引:12
|
作者
Wen, ZC
Chen, SA
Tai, CT
Chiang, CE
Lee, SH
Chen, YJ
Yu, WC
Huang, JL
Chang, MS
机构
[1] VET GEN HOSP,DIV CARDIOL,TAIPEI,TAIWAN
[2] NATL YANG MING UNIV,SCH MED,DEPT MED,DIV CARDIOL,TAIPEI 112,TAIWAN
[3] SHIN KONG MEM HOSP,DEPT MED,TAIPEI,TAIWAN
[4] VET GEN HOSP,DEPT MED,DIV CARDIOL,TAICHUNG,TAIWAN
关键词
atrial flutter; temperature control; radiofrequency; catheter ablation;
D O I
10.1111/j.1540-8167.1996.tb00480.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Information about temperature and impedance monitoring during radiofrequency catheter linear ablation of atrial flutter has not been reported. We proposed that a radiofrequency catheter ablation system using a closed-loop temperature control model could decrease the incidence of coagulum formation and shorten the radiation exposure and procedure times compared with those found in a power control model. Methods and Results: Forty patients (8 women and 32 men; mean age 64 +/- 7 years) with atrial flutter were referred for radiofrequency ablation. The patients were randomized into two groups: group I patients underwent radiofrequency catheter linear ablation of atrial flutter using a power control of energy output model; and group II patients underwent the closed-loop temperature control model with a target electrode temperature of 70 degrees C. As compared with group II, group I patients had a higher incidence of coagulum formation (12% vs 2%, P < 0.05), temperature shutdown (11% vs 0%, P < 0.01), and impedance shutdown (16% vs 3%, P < 0.01), more radiofrequency applications (7 +/- 3 vs 4 +/- 2, P < 0.01), and longer procedure time (100 +/- 25 vs 75 +/- 23 minutes, P < 0.05) and radiation exposure time (31 +/- 10 vs 20 +/- 7 minutes, P < 0.05) required for successful ablation. Larger deviations of temperature (9.0 degrees +/- 2.4 degrees C vs 5.0 degrees +/- 1.2 degrees C, P < 0.0001) and impedance (9.2 +/- 2.6 Ohm vs 5.3 +/- 1.6 Ohm, P < 0.0001) were also found in group I patients compared with those in group II. Conclusions: This study demonstrated that a closed-loop temperature control model could facilitate the effects of radiofrequency catheter ablation of the atrial flutter circuit by decreasing coagulum formation, temperature and impedance shutdown, and procedure and radiation exposure times.
引用
收藏
页码:1050 / 1057
页数:8
相关论文
共 50 条
  • [1] Radiofrequency catheter ablation of common atrial flutter: Comparison of electrophysiologically guided focal ablation technique and linear ablation technique
    Chen, SA
    Chiang, CE
    Wu, TJ
    Tai, CT
    Lee, SH
    Cheng, CC
    Chiou, CW
    Ueng, KC
    Wen, ZC
    Chang, MS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (04) : 860 - 868
  • [2] Radiofrequency catheter ablation of atrial flutter
    Schumacher, B
    Jung, W
    Lewalter, T
    Wolpert, C
    Luderitz, B
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 123 (22) : 701 - 706
  • [3] RADIOFREQUENCY CATHETER ABLATION OF ATRIAL-FLUTTER
    TOUBOUL, P
    KIRKORIAN, G
    MONCADA, E
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1994, 87 (11): : 1555 - 1561
  • [4] Results of radiofrequency catheter ablation for atrial flutter
    Saxon, LA
    Kalman, JM
    Olgin, JE
    Scheinman, MM
    Lee, RJ
    Lesh, MD
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (11): : 1014 - &
  • [5] Specific radiofrequency catheter ablation of atrial flutter
    Schlapfer, J
    Kappenberger, L
    Fromer, M
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1996, 126 (38) : 1591 - 1596
  • [6] Radiofrequency catheter ablation of atrial flutter in the young
    Manohar, NS
    Young, ML
    Wolff, GS
    PEDIATRIC RESEARCH, 2000, 47 (04) : 47A - 47A
  • [7] Radiofrequency catheter ablation of atrial flutter circuits
    Cosio, FG
    Arribas, F
    LopezGil, M
    Palacios, J
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1996, 89 : 75 - 81
  • [8] Radiofrequency catheter ablation of atrial flutter and fibrillation
    Saoudy, N
    Poty, H
    Cribier, AFA
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 337 - 339
  • [9] Radiofrequency catheter ablation of atrial tachycardia and atrial flutter
    Simons, GR
    Wharton, JM
    CORONARY ARTERY DISEASE, 1996, 7 (01) : 12 - 19
  • [10] Radiofrequency catheter ablation in atrial flutter and atrial fibrillation
    Reithmann, C
    Hoffmann, E
    Steinbeck, G
    HERZ, 1998, 23 (04) : 209 - 218