Framework for parametric assessment of operational and embodied energy impacts utilising BIM

被引:27
|
作者
Alwan, Zaid [1 ]
Nawarathna, Amalka [1 ]
Ayman, Rana [1 ]
Zhu, Mingyu [2 ]
ElGhazi, Yomna [3 ]
机构
[1] Northumbria Univ, Fac Engn & Environm, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
[2] Newcastle Univ, Sch Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[3] Sch Architecture Planning & Landscape, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
来源
关键词
Building information modelling; Operational energy; Embodied energy; Life cycle assessment; Parametric design; LIFE-CYCLE ASSESSMENT; DESIGN; LCA; OPTIMIZATION; BUILDINGS; COSTS;
D O I
10.1016/j.jobe.2021.102768
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years advances in digital tools have been leading the way in the construction of cleaner, more energy-efficient buildings. Furthermore, improvements in Building Information Modelling (BIM) have resulted in various tools being used to assess building performance and overall Life Cycle Analysis (LCA). This work offers a unique insight into the development of a parametric LCA BIM tool, focusing on both operational and embodied energy perspectives through case study analysis of a commercial and a domestic building in the UK. A mixed research method was employed combining a literature review, qualitative and quantitative LCA case study analysis, and parametric modelling. The results indicate that embodied energy is much more critical in the early stages of the building's life, then is quickly overtaken by operational energy. In addition, many variations exist in energy outputs between domestic and commercial buildings. Operational energy takes a significant share in domestic buildings compared to commercial buildings. These variations are attributed to different design methods, construction materials, occupancy patterns and energy demands. The study proposes an LCA-BIM interactive user-led method of addressing energy hotspots for both operational and embodied elements, which can provide more instant identification of energy critical areas. Such an approach can offer real alternative BIM-based analysis tools during the design stages, compared to those currently being used, which focus mainly on either LCA of operational or embodied energy.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Operational vs. Embodied Energy: a Case for Wood Construction
    Bejo, Laszlo
    DRVNA INDUSTRIJA, 2017, 68 (02) : 163 - 172
  • [42] A Framework for Quantitative Assessment of Impacts Related to Energy and Mineral Resource Development
    Haines S.S.
    Diffendorfer J.E.
    Balistrieri L.
    Berger B.
    Cook T.
    DeAngelis D.
    Doremus H.
    Gautier D.L.
    Gallegos T.
    Gerritsen M.
    Graffy E.
    Hawkins S.
    Johnson K.M.
    Macknick J.
    McMahon P.
    Modde T.
    Pierce B.
    Schuenemeyer J.H.
    Semmens D.
    Simon B.
    Taylor J.
    Walton-Day K.
    Natural Resources Research, 2014, 23 (1) : 3 - 17
  • [43] The relationship between operational energy demand and embodied energy in Dutch residential buildings
    Koezjakov, A.
    Urge-Vorsatz, D.
    Crijns-Graus, W.
    van den Broek, M.
    ENERGY AND BUILDINGS, 2018, 165 : 233 - 245
  • [44] EMBODIED ENERGY AND OPERATIONAL ENERGY: CASE STUDIES COMPARING DIFFERENT URBAN LAYOUTS
    Waldron, Diana
    Jones, Phil
    Lannon, Simon
    Bassett, Thomas
    Iorwerth, Heledd
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 1264 - 1271
  • [45] Parametric study of the impact of building envelope systems on embodied and operational carbon of residential buildings
    Hamida, Amneh
    Alsudairi, Abdulsalam
    Alshaibani, Khalid
    Alshamrani, Othman
    INTERNATIONAL JOURNAL OF BUILDING PATHOLOGY AND ADAPTATION, 2022, 40 (05) : 753 - 774
  • [46] Parametric study of the impact of building envelope systems on embodied and operational carbon of residential buildings
    Department of Architecture, College of Architecture and Planning, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
    不详
    Int. J. Build. Pathology Adapt., 5 (753-774):
  • [47] A statistical model of operational impacts on the framework of the bridge crane
    Antsev, V. Yu
    Tolokonnikov, A. S.
    Gorynin, A. D.
    Reutov, A. A.
    INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING, AUTOMATION AND CONTROL SYSTEMS 2016, 2017, 177
  • [48] Optimal BIM and LCA integration approach for embodied environmental impact assessment
    Tam, Vivian W. Y.
    Zhou, Yijun
    Shen, Liyin
    Le, Khoa N.
    JOURNAL OF CLEANER PRODUCTION, 2023, 385
  • [49] Embodied energy and operational energy evaluation in tall buildings according to different typologies of facade
    Giordano, Roberto
    Giovanardi, Matteo
    Guglielmo, Giulia
    Micono, Carlo
    SUSTAINABILITY IN ENERGY AND BUILDINGS 2017, 2017, 134 : 224 - 233
  • [50] Embodied and Operational Energy of a Case Study Villa in UAE with Sensitivity Analysis
    Rauf, Abdul
    Attoye, Daniel Efurosibina
    Crawford, Robert
    BUILDINGS, 2022, 12 (09)